The largest database of trusted experimental protocols

Anticoagulants

Anticoagulants are a class of drugs that prevent or reduce the formation of blood clots.
They work by interfering with the body's natural clotting mechanisms, reducing the risk of thrombosis and embolism.
Anticoagulants are commonly used to treat and prevent conditions like deep vein thrombosis, pulmonary embolosm, and atrial fibrillation.
They come in various forms, including oral medications, injectable drugs, and topical agents.
Reserachers can use PubCompare.ai's AI-driven platform to discover new anticoagulant protocols from literature, preprints, and patents, identify the best research strategies, and optimize their workflow for anticoagulant studies.

Most cited protocols related to «Anticoagulants»

Blood samples were obtained from 2180 adult outpatients, ages >18 years, at the department of clinical laboratory of Zhongshan Hospital. Blood was collected in tubes without anticoagulant from subjects after an overnight fast. The samples were allowed to clot at room temperature, and serum was obtained by centrifugation at 3000 rpm for 15 minutes. All blood lipid analyses were performed within 1 day. All subjects were classified into three groups according to the TG concentrations (A: < 200 mg/dl, n = 1220; B: 200-400 mg/dl, n = 480; C: 400-1000 mg/dl, n = 480). The Non-HDL-C concentrations in all samples were less than 300 mg/dl. To convert values for TG and cholesterol to millimoles per liter, we multiply the values with 0.0113 and 0.0259, respectively.
The Non-HDL-C value was estimated by the formula as follows [16 (link)]:
Lipid measurements were performed on a Hitachi 911 automatic analyzer. The LDL-C assay was performed according to Roche manufacture's specifications. At the same time, the LDL-C values were also calculated by the FF and MFF. TC and TG concentrations were determined enzymatically using CHOD-PAP and lipase/GPO/PAP methods, respectively. The HDL-C concentration was measured by phosphotungstic acid and MgCl2 precipitation approach. The reagents were obtained from Roche Diagnostics. The procedures and efficiency of lipid assays had been demonstrated previously [17 (link)]. The total error used in precision assessment was 3.95%-7.85% for the Roche method, as recommended by the National Cholesterol Education Program.
The FF was transformed as follows:
Multivariate linear regression analysis was used to investigate the relationship between LDL-C (expected value), TG and Non-HDL-C (explanatory variables) concentrations. Repeatability of the new formula was evaluated by Bland-Altman analysis [18 (link)]:. We compared the agreement between FF and our new formula, and calculated the mean and standard deviation of the differences (formula and lab value). The mean difference of both FF and new formula were close to zero. We concluded the MFF as follows:
Statistical analysis was performed using SPSS 11.5 for Windows (SPSS Inc., USA). Linear regression analyses were used to assess the correlations between the methods of formula calculation and direct measurement. To examine the degree of consistency between values obtained by the two methods, we used the graphical procedure outlined by Bland and Altman. Comparisons between groups were performed using the method of ANOVA. The test of Pearson chi-square was used to compare discrete variables. P values less than 0.05 were considered significant.
Full text: Click here
Publication 2010
Adult Anticoagulants Biological Assay BLOOD Centrifugation Cholesterol Clinical Laboratory Services Clotrimazole CVAD protocol Diagnosis Hematologic Tests Lipase Lipids Magnesium Chloride neuro-oncological ventral antigen 2, human Outpatients Phosphotungstic Acid Programmed Learning Serum
PD and HC subjects of similar age and gender from 24 study sites in the US (18), Europe (5) and Australia (1) were enrolled after obtaining informed consent. We acknowledge that the early PD cohort likely includes a small number of subjects with other DAT deficit parkinsonian syndromes such as progressive supranuclear palsy (PSP), multiple system atrophy (MSA) and cortical basal syndrome (CBS), which may be indistinguishable from PD at the earliest stages of disease. At each study visit, the investigators reassess the subject diagnosis to identify any non‐PD subjects.
This study was conducted in accordance with the Declaration of Helsinki and the Good Clinical Practice (GCP) guidelines after approval of the local ethics committees of the participating sites. At enrollment, PD subjects were required to be age 30 years or older, untreated with PD medications (levodopa, dopamine agonists, MAO‐B inhibitors, or amantadine), within 2 years of diagnosis, Hoehn and Yahr <3, and to have either at least two of resting tremor, bradykinesia, or rigidity (must have either resting tremor or bradykinesia) or a single asymmetric resting tremor or asymmetric bradykinesia. All PD subjects underwent dopamine transporter (DAT) imaging with 123I Ioflupane or vesicular monoamine transporter (VMAT‐2) imaging with 18F AV133 (Australia only) and were only eligible if DAT or VMAT‐2 imaging demonstrated dopaminergic deficit consistent with PD in addition to clinical features of the disease. Study investigators evaluated enrolled PD subjects to assess absence of current or imminent (6 months) disability requiring PD medications, though subjects could initiate PD medications at any time after enrollment if the subject or investigator deemed it clinically necessary. Those subjects screened as potential PD subjects who were ineligible due to DAT or VMAT‐2 scans without evidence of dopaminergic deficit (SWEDD) were eligible to be enrolled in a SWEDD cohort.4 HC subjects were required to be age 30 years or older without an active, clinically significant neurological disorder or a first‐degree relative with PD. All enrolled subjects agreed to complete all study evaluations, including lumbar puncture.
PD and SWEDD subjects were excluded if they had a clinical diagnosis of dementia or had taken PD medications within 60 days of baseline or for longer than 60 days in total. HC subjects were excluded if they had a Montreal Cognitive Assessment (MoCA) total score ≤26. All subjects were excluded if they were treated with neuroleptics, metoclopramide, alpha methyldopa, methylphenidate, reserpine, or amphetamine derivative within 6 months or were currently treated with anticoagulants that might preclude safe completion of the lumbar puncture.
Publication 2018
123I-ioflupane Amantadine Amphetamine Anticoagulants Antipsychotic Agents Bradykinesia Cortex, Cerebral Dementia Diagnosis Disabled Persons Dopamine Agonists Gender Hydrochloride, Dopamine Levodopa Methyldopa Methylphenidate Metoclopramide Monoamine Oxidase Inhibitors Multiple System Atrophy Muscle Rigidity Nervous System Disorder Parkinsonian Disorders Pharmaceutical Preparations Progressive Supranuclear Palsy Punctures, Lumbar Radionuclide Imaging Regional Ethics Committees Reserpine Resting Tremor SLC6A3 protein, human Syndrome Vesicular Monoamine Transport Proteins Volumetric-Modulated Arc Therapy

Protocol full text hidden due to copyright restrictions

Open the protocol to access the free full text link

Publication 2012
acid citrate dextrose Anticoagulants BLOOD Chromosomes Ethics Committees, Research Genome Genotype Hybrids Iplex Mass Spectrometry Methylation Multiplex Polymerase Chain Reaction Patients Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization Veins
The ACTS is a 15-item, patient-reported measure of satisfaction with anticoagulant treatment. It includes 12 items that assess the burdens of anticoagulant treatment and three items that assess the benefits of anticoagulant treatment. Patients are asked to rate their experiences of anticoagulant treatment during the past 4 weeks on a 5-point scale of intensity (1 = not at all, 2 = a little, 3 = moderately, 4 = quite a bit, 5 = extremely). The ACTS Burdens total score ranges from 12 to 60, and the ACTS Benefits total score ranges from 3 to 15. When used in clinical research, it is recommended that the ACTS Burdens scores are reverse-scored so that higher ACTS Burdens and Benefits scores indicate greater satisfaction with treatment. For the purposes of this psychometric evaluation, however, the original raw score data were analysed. French, Dutch, Italian, German and English language versions of the ACTS were created previously in accordance with a standard protocol to achieve conceptual equivalence in the translation, including: forward/backward translation, reconciliation, review and pilot testing [14 (link)]. Further information about the translation process is available from the authors.
For validation purposes, the TSQM II was also included. This is an 11-item PRO instrument that assesses patient satisfaction with treatment. It includes four scales: two items that assess the effectiveness of treatment (TSQM II Effectiveness), three items that assess side-effects (TSQM II Side-effects), three items that assess convenience of treatment (TSQM II Convenience) and two items that assess global satisfaction (TSQM II Global) [15 (link)]. Patients are asked to rate their experiences of treatment between ‘extremely dissatisfied’ and ‘extremely satisfied’ on 5-point to 7-point scales. Higher TSQM II scores indicate higher satisfaction with treatment.
Full text: Click here
Publication 2012
Anticoagulants Patients Psychometrics Satisfaction SERPINA3 protein, human
The candidates for this study were patients with suspected iNPH. After obtaining written informed consent, the eligible patients were pre-registered and received lumbar puncture. The inclusion criteria were (1) age between 60 and 85 years, (2) presence of one or more symptom(s) of the triad (gait disturbance, cognitive impairment, and urinary symptoms), which were measurable on the iNPH Grading Scale (iNPHGS) [14 (link)], (3) MRI features of iNPH, i.e., both ventriculomegaly of Evans' index > 0.3 and tight high-convexity and medial subarachnoid spaces on coronal T1-weighted MRI (Figure 1) [10 (link)], (4) absence of known disorders causing ventriculomegaly, and (5) normal cerebrospinal fluid (CSF) content (protein ≤ 50 mg/dl and cell count ≤ 3 μm3) and pressure (≤ 20 cmH2O). Exclusion criteria were (1) presence of musculoskeletal, cardiopulmonary, renal, hepatic, or mental disorders that would make it difficult to evaluate changes of symptoms, (2) obstacles to one-year follow-up, and (3) hemorrhagic diathesis or anticoagulant medication. For the evaluation of the MRIs, Evans' index, size of the Sylvian fissures rated according to the protocol of Kitagaki et al. [10 (link)], presence or absence of focal dilatation of the cerebral sulci, and white-matter changes according to scale of Fazekas et al. [15 (link)], were assessed on each site and recorded.
The candidates were pre-registered before CSF examination via a web-based case report system. MRI was reviewed by each site in the pre-registration phase, and the final eligibility of the subjects was judged by the central MRI review committee, which consist of neurosurgeons, neurologists, and a neuroradiologist. The central MRI review committee excluded those whose MRI did not fulfil the inclusion criteria. After the confirmation of normal CSF content and pressure, the investigator was notified of registration via the web system. Tap test was carried out in all subjects with 30 ml CSF removal via lumbar puncture. CT cisternography was carried out 1 week after the tap test with iohexol (Omnipaque®: 180 mg/ml) 30 mg/kg. Cerebral blood flow was measured using 123I-Iodoamphetamine and single photon emission computed tomography at baseline. However, the results of these measures were not considered for the eligibility.
Full text: Click here
Publication 2010
Anticoagulants Cerebrospinal Fluid Cerebrovascular Circulation Dilatation Disorders, Cognitive Eligibility Determination Hemorrhagic Disorders Iodine-123 Iohexol Kidney Mental Disorders Neurologists Neurosurgeon Omnipaque Patients Pressure Proteins Punctures, Lumbar Subarachnoid Space Tomography, Emission-Computed, Single-Photon Triad resin Urine White Matter

Most recents protocols related to «Anticoagulants»

Example 1

The sequence coding for the light chain variable region of the antibody was inserted into vector pFUSE2ss-CLIg-hK (Invivogen, Catalog Number: pfuse2ss-hclk) using EcoRI and BsiWI restriction sites to construct a light chain expression vector. The sequence coding for the heavy chain variable region of the antibody was inserted into vector pFUSEss-CHIg-hG2 (Invivogen, Catalog Number: pfusess-hchg2) or vector pFUSEss-CHIg-hG4 (Invivogen, Catalog Number: pfusess-hchg4) using EcoRI and NheI restriction sites to construct a heavy chain expression vector.

The culture and transfection of Expi293 cells were performed in accordance with the handbook of Expi293™ Expression System Kit from Invitrogen (Catalog Number: A14635). The density of the cells was adjusted to 2×106 cells/ml for transfection, and 0.6 μg of the light chain expression vector as described above and 0.4 μg of the heavy chain expression vector as described above were added to each ml of cell culture, and the supernatant of the culture was collected four days later.

The culture supernatant was subjected to non-reduced SDS-PAGE gel electrophoresis in accordance with the protocol described in Appendix 8, the Third edition of the “Molecular Cloning: A Laboratory Manual”.

Pictures were taken with a gel scanning imaging system from BEIJING JUNYI Electrophoresis Co., LTD and in-gel quantification was performed using Gel-PRO ANALYZER software to determine the expression levels of the antibodies after transient transfection. Results were expressed relative to the expression level of control antibody 1 (control antibody 1 was constructed according to U.S. Pat. No. 7,186,809, which comprises a light chain variable region as set forth in SEQ ID NO: 10 of U.S. Pat. No. 7,186,809 and a heavy chain variable region as set forth in SEQ ID NO: 12 of U.S. Pat. No. 7,186,809, the same below) (control antibody 2 was constructed according to U.S. Pat. No. 7,638,606, which comprises a light chain variable region as set forth in SEQ ID NO: 6 of U.S. Pat. No. 7,638,606 and a variable region as set forth in SEQ ID NO: 42 of U.S. Pat. No. 7,638,606, the same below). See Tables 2a-2c below for the results.

TABLE 2a
Expression levels of the antibodies of the present
invention after transient transfection (antibodies whose
expression levels are significantly higher than that of control antibody 1):
Number ofExpression level vsNumber of Expression level vs
the antibodycontrol antibody 1the antibodycontrol antibody 1
L1021H10002.08L1000H10281.27
L1020H10001.58L1000H10151.19
L1000H10271.56L1000H10321.18
L1000H10241.51L1000H10261.15
L1000H10251.48L1021H10291.12
L1001H10001.48L1000H10301.1
L1021H10161.43L1024H10311.08
L1000H10141.35L1000H10161.05

TABLE 2b
Expression levels of the antibodies of the present
invention after transient transfection (antibodies whose
expression levels are slightly lower than that of control antibody 1):
Number of Expression level vsNumber of Expression level vs
the antibodycontrol antibody 1the antibodycontrol antibody 1
L1000H10310.99L1017H10000.85
L1021H10310.99L1020H10160.84
L1020H10290.96L1000H10090.81
control anti-0.93L1000H10070.8
body 2
L1012H10000.89L1000H10230.8
L1019H10000.87L1020H10270.78
L1020H10310.87L1024H10070.77
L1021H10200.87L1000H10130.75
L1000H10290.86L1020H10070.74
L1008H10000.86L1021H10070.74
L1000H10010.85L1000H10210.71

TABLE 2c
Expression levels of the antibodies of the present
invention after transient transfection (antibodies whose
expression levels are significantly lower than that of control antibody 1):
Number ofExpression level vsNumber of Expression level vs
the antibodycontrol antibody 1the antibodycontrol antibody 1
L1000H10200.69L1024H10000.52
L1010H10000.69L1000H10080.51
L1000H10220.67L1000H10370.5
L1000H10120.64L1007H10000.49
L1022H10000.64L1016H10000.49
L1011H10000.63L1000H10170.47
L1000H10110.62L1000H10350.46
L1000H10330.62L1012H10270.46
L1020H10200.61L1018H10000.44
L1000H10360.6L1023H10000.43
L1021H10270.6L1012H10160.42
L1012H10070.59L1013H10000.41
L1009H10000.57L1000H10340.4
L1012H10200.57L1000H10180.35
L1012H10310.56L1000H10190.34
L1000H10380.54L1015H10000.27
L1012H10290.54L1014H10000.17
L1000H10100.53

Example 4

6-8 week-old SPF Balb/c mice were selected and injected subcutaneously with antibodies (the antibodies of the present invention or control antibody 2) in a dose of 5 mg/kg (weight of the mouse). Blood samples were collected at the time points before administration (0 h) and at 2, 8, 24, 48, 72, 120, 168, 216, 264, 336 h after administration. For blood sampling, the animals were anesthetized by inhaling isoflurane, blood samples were taken from the orbital venous plexus, and the sampling volume for each animal was about 0.1 ml; 336 h after administration, the animals were anesthetized by inhaling isoflurane and then euthanized after taking blood in the inferior vena cava.

No anticoagulant was added to the blood samples, and serum was isolated from each sample by centrifugation at 1500 g for 10 min at room temperature within 2 h after blood sampling. The collected supernatants were immediately transferred to new labeled centrifuge tubes and then stored at −70° C. for temporary storage. The concentrations of the antibodies in the mice were determined by ELISA:

1. Preparation of Reagents

sIL-4Rα (PEPRO TECH, Catalog Number: 200-04R) solution: sIL-4Rα was taken and 1 ml ddH2O was added therein, mixed up and down, and then a solution of 100 μg/ml was obtained. The solution was stored in a refrigerator at −20° C. after being subpacked.

Sample to be tested: 1 μl of serum collected at different time points was added to 999 μl of PBS containing 1% BSA to prepare a serum sample to be tested of 1:1000 dilution.

Standard sample: The antibody to be tested was diluted to 0.1 μg/ml with PBS containing 1% BSA and 0.1% normal animal serum (Beyotime, Catalog Number: ST023). Afterwards, 200, 400, 600, 800, 900, 950, 990 and 1000 μl of PBS containing 1% BSA and 0.1% normal animal serum were respectively added to 800, 600, 400, 200, 100, 50, 10 and 0 μl of 0.1 μg/ml antibodies to be tested, and thus standard samples of the antibodies of the present invention were prepared with a final concentration of 80, 60, 40, 20, 10, 5, 1, or 0 ng/ml respectively.

2. Detection by ELISA

250 μl of 100 μg/ml sIL-4Rα solution was added to 9.75 ml of PBS, mixed up and down, and then an antigen coating buffer of 2.5 μg/ml was obtained. The prepared antigen coating buffer was added to a 96-well ELISA plate (Corning) with a volume of 100 μl per well. The 96-well ELISA plate was incubated overnight in a refrigerator at 4° C. after being wrapped with preservative film (or covered). On the next day, the 96-well ELISA plate was taken out and the solution therein was discarded, and PBS containing 2% BSA was added thereto with a volume of 300 μl per well. The 96-well ELISA plate was incubated for 2 hours in a refrigerator at 4° C. after being wrapped with preservative film (or covered). Then the 96-well ELISA plate was taken out and the solution therein was discarded, and the plate was washed 3 times with PBST. The diluted standard antibodies and the sera to be detected were sequentially added to the corresponding wells, and three duplicate wells were made for each sample with a volume of 100 μl per well. The ELISA plate was wrapped with preservative film (or covered) and incubated for 1 h at room temperature. Subsequently, the solution in the 96-well ELISA plate was discarded and then the plate was washed with PBST for 3 times. Later, TMB solution (Solarbio, Catalog Number: PR1200) was added to the 96-well ELISA plate row by row with a volume of 100 μl per well. The 96-well ELISA plate was placed at room temperature for 5 minutes, and 2 M H2SO4 solution was added in immediately to terminate the reaction. The 96-well ELISA plate was then placed in flexstation 3 (Molecular Devices), the values of OD450 were read, the data were collected and the results were calculated with Winnonlin software. The pharmacokinetic results were shown in FIG. 1 and Table 6 below.

TABLE 6
Pharmacokinetic results of the antibodies of the present invention in mouse
Area
TimeUnder the
HalftoPeakdrug-timeVolume ofClearance
lifepeakconcentrationCurvedistributionrate
Numberhhμg/mlh*μg/mlml/kgml/h/kg
L1020H1031Mean269.347233.797679.28138.920.38
value
Standard105.730.000.42163.9122.480.09
deviation
L1012H1031Mean167.274845.59852.391.30.38
value
Standard8.520.001.86448.345.580.00
deviation
ControlMean56.67367.881132.68288.923.79
antibody 2value
Standard25.8416.970.2594.4249.451.12
deviation

Example 5

A series of pharmacokinetic experiments were carried out in Macaca fascicularises to further screen antibodies.

3-5 year-old Macaca fascicularises each weighting 2-5 Kg were selected and injected subcutaneously with antibodies (the antibodies of the present invention or control antibody 2) in a dose of 5 mg/kg (weight of the Macaca fascicularis). The antibody or control antibody 2 to be administered was accurately extracted with a disposable aseptic injector, and multi-point injections were made subcutaneously on the inner side of the thigh of the animal, and the injection volume per point was not more than 2 ml. Whole blood samples were collected from the subcutaneous vein of the hind limb of the animal at the time points before administration (0 h) and at 0.5, 2, 4, 8, 24, 48, 72, 120, 168, 240, 336 h, 432 h, 504 h, 600 h, 672 h after administration. The blood volume collected from each animal was about 0.1 ml each time.

No anticoagulant was added to the blood samples, and serum was isolated from each sample by centrifugation at 1500 g for 10 min at room temperature within 2 h after blood sampling. The collected supernatants were immediately transferred to new labeled centrifuge tubes and then stored at −70° C. for temporary storage. The concentrations of the antibodies in the Macaca fascicularises were determined according the method as described in Example 4. The pharmacokinetic results are shown in FIG. 2 and Table 7 below.

TABLE 7
Pharmacokinetic results of the antibodies of the present invention in macaca fascicularis
Area
TimeUnder the
HalftoPeakdrug-timeVolume ofClearance
lifepeakconcentrationCurvedistributionrate
Numberhhμg/mlh*μg/mlml/kgml/h/kg
L1020H1031Mean254.9548.0089.6522189.9175.940.22
value
Standard44.5733.9444.298557.1522.950.10
deviation
L1012H1031Mean185.75486516185.7373.410.28
value
Standard42.5433.944.52506.980.810.06
deviation
ControlMean37.031637.822773.2193.971.78
antibody 2value
Standard18.0311.316.75155.8442.470.07
deviation

Example 10

In vivo pharmacokinetics of the antibodies of the invention are further detected and compared in this Example, in order to investigate the possible effects of specific amino acids at specific positions on the pharmacokinetics of the antibodies in animals. The specific experimental method was the same as that described in Example 4, and the results are shown in Table 9 below.

TABLE 9
Detection results of in vivo pharmacokinetics of the antibodies of the present invention
Area
TimeUnder the
HalftoPeakdrug-timeVolume ofClearance
lifepeakconcentrationCurvedistributionrate
hhug/mlh*ug/mlml/kgml/h/kg
L1020H1031Mean185.494038.948188.8114.280.43
value
Standard18.5213.862.33510.476.50.05
deviation
L1012H1001Mean161.2648.0012.362491.19332.791.47
value
Standard54.300.002.26165.1676.910.20
deviation
L1001H1031Mean171.4156.0042.749273.7399.170.40
value
Standard6.1213.867.381868.6618.690.07
deviation
L1020H1001Mean89.0064.0020.113481.40164.141.30
value
Standard16.7013.862.14268.3922.860.20
deviation

From the specific sequence, the amino acid at position 103 in the sequence of the heavy chain H1031 (SEQ ID NO. 91) of the antibody (in CDR3) is Asp (103Asp), and the amino acid at position 104 is Tyr (104Tyr). Compared with antibodies that have no 103Asp and 104Tyr in heavy chain, the present antibodies which have 103Asp and 104Tyr have a 2- to 4-fold higher area under the drug-time curve and an about 70% reduced clearance rate.

The expression levels of the antibodies of the present invention are also detected and compared, in order to investigate the possible effects of specific amino acids at specific positions on the expression of the antibodies. Culture and transfection of Expi293 cells were conducted according to Example 1, and the collected culture supernatant was then passed through a 0.22 μm filter and then purified by GE MabSelect Sure (Catalog Number: 11003494) Protein A affinity chromatography column in the purification system GE AKTA purifier 10. The purified antibody was collected and concentrated using Amicon ultrafiltration concentrating tube (Catalog Number: UFC903096) and then quantified. The quantitative results are shown in Table 10 below.

TABLE 10
Detection results of the expression
levels of the antibodies of the present invention
Expression level
Antibody(×10−2 mg/ml culture medium)
L1020H10318.39
L1001H10311.79
L1020H10014.04
L1012H10015.00
L1023H10014.63
L1001H10011.75

From the specific sequence, the amino acid at position 31 in the sequence of the light chain L1012 (SEQ ID NO. 44), L1020 (SEQ ID NO. 55) or L1023 (SEQ ID NO. 51) of the antibody (in CDR1) is Ser (31Ser). Compared with antibodies that have no 31Ser in light chain, the present antibodies which have 31Ser have a 2- to 5-fold higher expression level.

The above description for the embodiments of the present invention is not intended to limit the present invention, and those skilled in the art can make various changes and variations according to the present invention, which are within the protection scope of the claims of the present invention without departing from the spirit of the same.

Full text: Click here
Patent 2024
Amino Acids Animals Antibodies Anticoagulants Antigens Asepsis BLOOD Blood Volume Buffers Cell Culture Techniques Cells Centrifugation Chromatography Chromatography, Affinity Cloning Vectors Culture Media Deoxyribonuclease EcoRI Drug Kinetics Electrophoresis Enzyme-Linked Immunosorbent Assay Hindlimb Human Body Immunoglobulin Heavy Chains Immunoglobulin Light Chains Immunoglobulins Interleukin-1 Isoflurane Light Macaca Macaca fascicularis Medical Devices Metabolic Clearance Rate Mice, Inbred BALB C Mus Open Reading Frames Pharmaceutical Preparations Pharmaceutical Preservatives SDS-PAGE Serum Staphylococcal Protein A Technique, Dilution Thigh Transfection Transients Ultrafiltration Veins Vena Cavas, Inferior
Not available on PMC !

Example 1

Whole blood were collected from volunteer donors must be performed by personal trained in phlebotomy/venipuncture using a double blood bag system (about 50 ml) (TerumoBCT, Japan) with anticoagulant (1 ml of Anticoagulant Citrate Dextrose (ACD) Solution Formula/per 10 ml of blood). After blood collection, gently mix the blood by inverting the tube several times to ensure thorough mixing with anticoagulant. For thorough mixing of blood collected into citrate tubes, it is recommended to invert the tube 3-4 times, while ACD tubes should be inverted eight times. Blood samples should be maintained at temperate conditions (20-24° C.) and centrifuged within 4 hours of blood collection. To separate the plasma, centrifuge the blood samples at 1200×g for 10 minutes at 22° C. If needed, RCF for a centrifuge can be calculated. After centrifugation, the plasma layer will be the upper layer of the separated blood and appear a clear, straw-yellow colored fluid.

Full text: Click here
Patent 2024
Anticoagulants BLOOD Centrifugation Citrates Donors Glucose Hemic System isolation Phlebotomy Plasma Voluntary Workers
A blood sample (approximately 6 mL) was drawn from the forearm vein into a tube containing an anticoagulant following overnight fasting on the day of surgery. The mixture was immediately centrifuged at 4000×g for 10 min at 4 °C. A vitreous sample (approximately 1 mL) was carefully collected into a 2 mL sterile syringe using a 25-gauge vitreous cutter and manual suction before opening the intraocular irrigation system. If vitreous hemorrhage was present, the surgeon avoided collecting blood components as much blood as possible. All samples were stored in cryopreservation tubes and immediately cooled at − 80 °C until analysis.
After sample collection, total RNA was extracted using TRIzol LS reagent (Invitrogen, Carlsbad, CA, USA) combined with miRNeasy Micro Kit (Qiagen, Hilden, Germany). RNA quality and integrity were measured using Nanodrop (Thermo Fisher Scientific, Waltham, MA, USA) and Agilent 4200 TapeStation.
Full text: Click here
Publication 2023
Anticoagulants BLOOD Blood Component Transfusion Cryopreservation Forearm Specimen Collection Sterility, Reproductive Suction Drainage Surgeons Surgery, Day Syringes trizol Veins Vitreous Hemorrhage
Blood samples were collected after decapitation in a vacutainer tube containing EDTA as an anticoagulant for the assay of pro-oxidative markers in the plasma and antioxidant markers in the lysate. The samples were centrifuged at 3000 rpm for 10 min at 4 °C using a Centurion centrifuge (K280R, UK). The plasma and erythrocyte lysate were then stored at -20 °C until analysis. All measurements were performed spectrophotometrically (Shimadzu UV-1800, Japan).
Full text: Click here
Publication 2023
Anticoagulants Antioxidants Biological Assay BLOOD Decapitation Edetic Acid Erythrocytes Plasma
A temporary filter was inserted via the nonaffected femoral or jugular vein into the inferior vena cava (IVC) prior to the next procedure for patients with an extensive thrombus in the proximal vein that was evaluated as potentially life-threatening and was retrieved after the proximal DVT was removed and potentially life-threatening conditions were relieved. Consistent with local routines based on published guidelines [9 ], anticoagulant treatment was initiated immediately when DVT was identified with the use of subcutaneous low molecular weight heparin (LMWH) at a bolus dose of 100 units/kg twice daily. PTA and/or stent placement was encouraged for lesions that caused 50% or greater diameter narrowing of the iliac and/or common femoral vein, robust collateral filling, and/or a mean pressure gradient of more than 2 mmHg. At the end of LMWH, oral rivaroxaban was directly commenced at a dosage of 15 mg twice a day over the subsequent 21 days and 20 mg once a day thereafter for at least 6 months. In addition, the use of compression stockings (ankle pressure was approximately 30–40 mmHg) for more than 1 year was recommended.
Full text: Click here
Publication 2023
Ankle Anticoagulants Compression Stockings Femur Heparin, Low-Molecular-Weight Ilium Jugular Vein Patients Pressure Rivaroxaban Stents Thrombus Vein, Femoral Veins Vena Cavas, Inferior

Top products related to «Anticoagulants»

Sourced in United States, United Kingdom, Brazil, Germany, Canada, France, Spain, Italy, Switzerland, Australia, Sweden, Belgium, New Zealand, Denmark, Mexico, Jersey, South Sudan, Austria, Japan
The BD Vacutainer is a blood collection system used to collect, process, and preserve blood samples. It consists of a sterile evacuated glass or plastic tube with a closure that maintains the vacuum. The Vacutainer provides a standardized method for drawing blood samples for laboratory analysis.
Sourced in United States, United Kingdom, Canada, Australia, Germany, France, Brazil, Spain, Switzerland, Sweden, Belgium, Singapore, New Zealand, Italy, Japan, India
Vacutainer tubes are laboratory collection tubes used to obtain blood samples from patients. They are designed to maintain the integrity of the collected sample and prevent contamination. The tubes come in various sizes and contain different additives that help preserve the sample for subsequent analysis.
Sourced in United States, China, Japan, Germany, United Kingdom, Canada, France, Italy, Australia, Spain, Switzerland, Netherlands, Belgium, Lithuania, Denmark, Singapore, New Zealand, India, Brazil, Argentina, Sweden, Norway, Austria, Poland, Finland, Israel, Hong Kong, Cameroon, Sao Tome and Principe, Macao, Taiwan, Province of China, Thailand
TRIzol reagent is a monophasic solution of phenol, guanidine isothiocyanate, and other proprietary components designed for the isolation of total RNA, DNA, and proteins from a variety of biological samples. The reagent maintains the integrity of the RNA while disrupting cells and dissolving cell components.
Sourced in Sweden, United States, United Kingdom, Germany, Canada, Japan, Italy, China, France, Australia, Belgium, Austria, Spain, Switzerland, Norway, New Zealand, Denmark, Finland, Georgia
Ficoll-Paque PLUS is a sterile, ready-to-use medium for the isolation of mononuclear cells from blood or bone marrow by density gradient centrifugation. It is a polysucrose and sodium diatrizoate solution with a density of 1.077 g/mL.
Sourced in Germany, United States, Spain, United Kingdom, Japan, Netherlands, France, China, Canada, Italy, Australia, Switzerland, India, Brazil, Norway
The QIAamp DNA Blood Mini Kit is a laboratory equipment designed for the extraction and purification of genomic DNA from small volumes of whole blood, buffy coat, plasma, or serum samples. It utilizes a silica-based membrane technology to efficiently capture and wash DNA, while removing contaminants and inhibitors.
Sourced in United States, China, United Kingdom, Germany, Australia, Japan, Canada, Italy, France, Switzerland, New Zealand, Brazil, Belgium, India, Spain, Israel, Austria, Poland, Ireland, Sweden, Macao, Netherlands, Denmark, Cameroon, Singapore, Portugal, Argentina, Holy See (Vatican City State), Morocco, Uruguay, Mexico, Thailand, Sao Tome and Principe, Hungary, Panama, Hong Kong, Norway, United Arab Emirates, Czechia, Russian Federation, Chile, Moldova, Republic of, Gabon, Palestine, State of, Saudi Arabia, Senegal
Fetal Bovine Serum (FBS) is a cell culture supplement derived from the blood of bovine fetuses. FBS provides a source of proteins, growth factors, and other components that support the growth and maintenance of various cell types in in vitro cell culture applications.
Sourced in United States, Germany, United Kingdom, Sao Tome and Principe, Italy, Canada, Macao, Switzerland, Spain, France, Poland, Japan, Ireland, Hungary, Brazil, Norway, Israel, Belgium
Histopaque-1077 is a density gradient medium used for the isolation of mononuclear cells from whole blood. It is a sterile, endotoxin-tested solution composed of polysucrose and sodium diatrizoate, adjusted to a density of 1.077 g/mL.
Sourced in Austria, Germany, United States, United Kingdom, Belgium, Switzerland, Italy, France, Spain, Brazil
The Vacuette is a laboratory equipment designed to collect and store blood samples. It provides a closed vacuum system to draw blood samples efficiently and safely.
Sourced in United States, China, Germany, Japan, United Kingdom, Spain, Canada, France, Australia, Italy, Switzerland, Sweden, Denmark, Lithuania, Belgium, Netherlands, Uruguay, Morocco, India, Czechia, Portugal, Poland, Ireland, Gabon, Finland, Panama
The NanoDrop 2000 is a spectrophotometer designed for the analysis of small volume samples. It enables rapid and accurate quantification of proteins, DNA, and RNA by measuring the absorbance of the sample. The NanoDrop 2000 utilizes a patented sample retention system that requires only 1-2 microliters of sample for each measurement.

More about "Anticoagulants"

Anticoagulants are a class of medications that play a crucial role in preventing and treating conditions related to blood clotting.
These drugs work by interfering with the body's natural clotting mechanisms, reducing the risk of thrombosis (blood clots) and embolism (blockages caused by clots).
Anticoagulants, also known as 'blood thinners,' come in various forms, including oral medications, injectable drugs, and topical agents.
They are commonly used to manage and prevent conditions such as deep vein thrombosis (DVT), pulmonary embolism, and atrial fibrillation (AF).
Researchers can leverage the power of AI-driven platforms like PubCompare.ai to discover new anticoagulant protocols from literature, preprints, and patents, identify the best research strategies, and optimize their workflow for anticoagulant studies.
When conducting research on anticoagulants, researchers may utilize various laboratory techniques and equipment, such as BD Vacutainer® tubes for blood collection, TRIzol® reagent for RNA extraction, Ficoll-Paque PLUS for density gradient centrifugation, QIAamp® DNA Blood Mini Kit for DNA purification, and Histopaque-1077 for isolating mononuclear cells.
Additionally, Vacuette® blood collection systems and the NanoDrop 2000 spectrophotometer can be employed in the research process.
Researchers can explore the diverse range of anticoagulant options, understand their mechanisms of action, and investigate new protocols and strategies using AI-powered platforms like PubCompare.ai.
By leveraging these tools, researchers can enhance the reproducibility and optimization of their anticoagulant research workflows, ultimately contributing to advancements in the field of thrombosis management and prevention.