The largest database of trusted experimental protocols

Chemostation software

Manufactured by Agilent Technologies
Sourced in United States

CHEMOSTATION software is a data analysis and instrument control software for Agilent Technologies' analytical instruments. It provides a platform for acquiring, processing, and managing data from various analytical techniques such as chromatography, spectroscopy, and mass spectrometry.

Automatically generated - may contain errors

2 protocols using chemostation software

1

Quantifying Sevoflurane Blood Concentration

Check if the same lab product or an alternative is used in the 5 most similar protocols
The HP 6890 series GC system (Hewlett-Packard, Wilmington, DE) comprised a headspace sampler (Agilent G1888), an oven, a flame-ionization detector and an integrator. The oven temperature was set at 40°C, increased to 200°C at a rate of 25°C per minute and maintained at this level for 2.60 min. Both the injection and detection temperatures were set at 250°C. The inlet pressure was set at 349 kPa. Injection was performed in the direct injection mode. The carrier gas (helium) flow was 25.0 ml min-1. Separation was achieved with a capillary column (HP-5; 30.0 m × 0.32 mm ID, 0.25-μm film thickness; Restek, Bellefonte, PA). An integrator and a data acquisition system were provided by Agilent CHEMOSTATION software. The method used to create a calibration curve for measuring the blood sevoflurane concentration was modified according to our previous publication 13 (link). The mean (SD) of the blood/gas partition coefficient of sevoflurane (λ) for 32 patients was 0.65 (0.01).
+ Open protocol
+ Expand
2

Fatty Acid Methyl Ester Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The fatty acid methyl esters (FAMEs) were prepared according to the International Dairy Federation method (IDF 182:2002: ISO 15884:2002, Milkfat: Preparation of fatty acid methyl esters). n-hexane and 2M KOH in methanol were added to the fat sample and the mixture was shaken. Then, the sodium hydrogen sulfate (NaHSO4) was added, and the mixture was centrifuged (3000 min−1) [66 ]. Chromatographic separation producing FAMEs was carried out using the gas chromatography (GC) technique using a Hewlett-Packard 6890 chromatograph with a flame ionization detector (FID) and a capillary column Supelcowax 10 (length—100 m, inner diameter—0.25 mm, liquid phase—Supelcowax 30, film thickness—0.25 mm; temperature: detector = 250 °C, dispenser = 230 °C, column = 195 °C; carrier gas—helium, flow rate—1.5 mL/min). The identification of fatty acids was performed on the basis of their retention times in relation to the retention times of FAME standards (Supelco 37 Component FAME mixture (10 mg/mL in methylene chloride)). Chemostation software (Agilent, Alpharetta, GA, USA) was used to obtain the percentage of fatty acids, and the amount of fatty acids was expressed as the weight percentage of all FAMEs [67 ].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!