The largest database of trusted experimental protocols

3 protocols using cyanine5 alkyne

1

Copper-catalyzed Azide-Alkyne Cycloaddition

Check if the same lab product or an alternative is used in the 5 most similar protocols
Final concentrations of 1 mM DAz-2 (Cayman Chemical), 1 mM Cyanine5 alkyne (Lumiprobe), 2 mM copper(II)-TBTA complex (Lumiprobe) and 4 mM ascorbic acid made in situ, were added sequentially in 15 mM PBS buffer mixed with 30% (vol/vol) acetonitrile. The solution was mixed at RT overnight and then quenched with 20 mM ethylenediaminetetraacetic acid (EDTA) and mixed at RT for 2 hr.
+ Open protocol
+ Expand
2

Cy5 Analog Compound Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cy5 analogs were purchased from Lumiprobe (Cyanine5 NHS ester (#13020), Cyanine5 Maleimide (#13080), Cyanine5 Azide (#A3030), Cyanine5 Alkyne (#A30B0), Cyanine5 Hydrazide (#13070), Cyanine5 Amine (#130C0), Cyanine5 Carboxylic Acid (#13090). All Cy5 compounds were dissolved at 10 mM in DMSO and stored at -20°C.
+ Open protocol
+ Expand
3

Synthesis and Characterization of Cy5-B12 Conjugate

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cy5-B12 was synthesized through Huisgen/Sharpless ‘Click’ Chemistry47 ,48 (link). Cu(I) (1mg, 0.005mmol) and Tris[(1-benzyl-1H-1,2,3-triazol-4-yl)methyl]amine (3.5mg, 0.006mmol) were dissolved in 0.5mL DMF/H2O (4:1 v/v). Once color change occurred, the previously synthesized B12-Azide (3mg, 0.002mmol)49 (link) and Cyanine-5 alkyne (0.5mg, 0.0007mmol) (Lumiprobe) was dissolved in the solution and allowed to stir at room temperature overnight protected from light. This was purified through RP-HPLC on a Shimadzu Prominence HPLC using a C18 column (Eclipse XDB-C18 5 μm, 4.6 × 150mm). Solvents: A: 0.1% TFA water and B: Acetonitrile. Method: B%: 20-72% over 18min. tR: 4.7min. Yield: 94%. LC-MS analysis (Shimadzu LCMS-8040, Method: 0.1% Formic acid and 35% methanol water at 0.2mL/min, DL temp: 150°C, heat block temp: 400°C.): expected m/z: 2059 observed: 1031 [M+2H]+2, 1042 [M+Na+2H]+2, and 1050 [M+K+2H]+2. Emission and excitation were 645 and 682nm, respectively using a Varian Cary UV Spectrophotometer and Agilent Cary Eclipse Fluorescence Spectrophotometer, solvent H2O. See Figure 1 for more information.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!