Bbo multinuclear probe

Manufactured by Bruker
Sourced in Germany

The BBO multinuclear probe is a laboratory equipment designed by Bruker for nuclear magnetic resonance (NMR) spectroscopy. It is capable of detecting and analyzing multiple nuclei simultaneously, including 1H, 13C, 15N, and 31P. The probe's core function is to provide researchers with a versatile tool for conducting advanced NMR experiments and analyses in a variety of scientific disciplines.

Automatically generated - may contain errors

2 protocols using bbo multinuclear probe

1

Characterization of Nanocrystals in DMF

Check if the same lab product or an alternative is used in the 5 most similar protocols
All UV-vis absorption spectra of NCs dissolved in DMF were recorded using an Agilent 8453 diode array spectrometer, with the background corrected by using a DMF blank. Solid samples were dissolved in DMF to make a dilute solution, which was transferred to a 1 cm path length quartz cuvette for spectral measurements.
PL spectra were measured on an FL-4500 spectrofluorometer with the same optical density (OD) of ∼0.05. In these experiments, the NC solutions were prepared in DMF at a concentration of less than 1 mg mL–1.
Absolute quantum yields (QYs) were measured with dilute solutions of NCs (0.05 OD absorption at 445 nm) on a HORIBA FluoroMax-4P.
31P NMR spectra were acquired using a Bruker 600 Avance III spectrometer equipped with a Bruker BBO multinuclear probe (BrukerBioSpin, Rheinstetten, Germany). To achieve a sufficient signal-to-noise ratio, the 31P NMR spectra were recorded by collecting 1k scans with a recycle delay time of 5 s.
Electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) measurements were performed on a MicrOTOF-QIII high-resolution mass spectrometer.
+ Open protocol
+ Expand
2

Characterization of Ag29 Nanoclusters

Check if the same lab product or an alternative is used in the 5 most similar protocols
All UV-vis absorption spectra of nanoclusters were recorded using an Agilent 8453 diode array spectrometer. PL spectra were measured on a FL-4500 spectrofluorometer with the same optical density of 0.1. ESI-MS measurements were performed by MicrOTOF-QIII highresolution mass spectrometer. The sample was directly infused into the chamber at 5 μL/min. For preparing the ESI samples, nanoclusters were dissolved in DMF/NMP/TMS (1 mg/mL) and diluted (v/v = 1:2) by methanol. 133Cs and 31P NMR spectra were acquired using a Bruker 600 Avance III spectrometer equipped with a Bruker BBO multinuclear probe (BrukerBioSpin, Rheinstetten, Germany). The Ag29-based assemblies were imaged with an aberration-corrected HAADF-STEM technique after the solvent that contained Ag29-based assemblies was dropped casting onto ultrathin carbon film TEM grids. The microscope employed was a FEI Themis Z. The electron beam energy was 200 kV. The collecting angle HAADF detector was used to collect signals scattered between 52 (inner angle) and 200 (outer angle) mrad (camera length of 146 mm). The aberration-corrected HAADF-STEM image was obtained by Thermo Scientific Velox software using 1024*1024 pixels and dwell time was set to 10 us.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!