The largest database of trusted experimental protocols

Atomlab 500 dose calibrator and wipe tester

Manufactured by Mirion Technologies
Sourced in United States

The Atomlab 500 is a dose calibrator and wipe tester manufactured by Mirion Technologies. It is designed to measure the activity of radioactive samples and perform wipe tests to detect potential contamination. The device provides accurate and reliable measurements to support various applications in the field of radiation detection and monitoring.

Automatically generated - may contain errors

2 protocols using atomlab 500 dose calibrator and wipe tester

1

Radiolabeling of TCPP with Copper-64

Check if the same lab product or an alternative is used in the 5 most similar protocols
64Cu was purchased from PET radioisotopes manufacturer (Voxel, Cracow, Poland) and was produced in 64Ni(p,n)64Cu reaction conducted on ALCEO solid target system (Comecer, Italy) coupled with GE PETrace 840 cyclotron (GE Healthcare Technologies Inc., Chicago, IL, USA). The requested activity was about 200 MBq in the form of dried 64CuCl2 reconstituted on-site with 1 mL of water. Stock porphyrin solution, buffers, and 0.05 mol L−1 ascorbic acid (Merck KGaA, Darmstadt, Germany) were prepared as described above. Water and phosphate-buffered saline (PBS) were of pharmaceutical grade. 64CuTCPP was synthesized at room temperature by mixing 200 μL of 64CuCl2 solution, 400 μL of TCPP, and 200 μL AA stock solutions, filled up with a borate buffer up to 5 mL, and vortexed. For final purification and formulation solution was loaded on anion exchange Waters Sep-Pak Accell Plus QMA column (Waters Corporation, Milford, CT, USA) with an ISM833 Ismatec peristaltic pump (VWR, Radnor, PA, USA) at 1 mL min−1, flushed with 5 mL of water at 2 mL min−1, acidified with 1 mL of 0.1 mol L−1 HCl and finally eluted with 0.5 mL of ethanol. After evaporation near dryness, small aliquot of PBS was added to reach expected activity concentration. An Atomlab 500 dose calibrator and wipe tester (Biodex, Shirley, NY, USA) was used for activity determination.
+ Open protocol
+ Expand
2

Radiopharmaceutical Characterization and Stability

Check if the same lab product or an alternative is used in the 5 most similar protocols
An ISMATEC peristaltic pump and 11 Elite (Harvard Apparatus, Holliston, MA, USA) syringe pump were used for liquid transfers, an Atomlab 500 dose calibrator and wipe tester (Biodex, Shirley, NY, USA) was used for activity determination, a Bioscan TLC reader Miniscan (Bioscan, Washington, DC, USA) with BioChrome software was used for thin layer chromatogram evaluations, a Thermo Scientific iCAP 6000ICP OES spectrometer was used for impurity determination. The instrumental settings of the manufacturers were as follows: RF generator power 1.15 kW, auxiliary gas flow 0.5 L min−1, nebulizer gas flow 0.40 L min−1, coolant gas flow 12 L min−1. For stability assessment the Shimadzu AD20 HPLC system with UV-Vis (ultraviolet-visible) and radiometric detector GabiStar (Raytest, Straubenhardt, Germany) was used.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!