Labospect 006

Manufactured by Hitachi
Sourced in Japan

Labospect 006 is a high-precision laboratory equipment designed for analytical applications. It offers advanced features and functionality to support various research and testing procedures in laboratory settings. The core function of Labospect 006 is to provide accurate and reliable measurements, data analysis, and sample preparation capabilities to meet the demands of modern laboratory workflows.

Automatically generated - may contain errors

10 protocols using labospect 006

1

Serum Biomarker Measurement Protocols

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum hsCRP was measured by latex nephelometry using the "fully automated immunochemistry analyzer BN-" (Siemens Healthcare Diagnostics, Tokyo, Japan). Serum Alb and T-Bil levels were measured using the bromocresol purple improvement method and the Japan Society of Clinical Chemistry standardization method, respectively, using "LABOSPECT 006" (Hitachi High-Tech, Tokyo, Japan). Moreover, serum UA was measured by the uricase/peroxidase method using "LABOSPECT 006" (Hitachi High-Tech). Serum PRL was measured by chemiluminescence immunoassay using the "Cobas 8000 e801 module" (Roche Diagnostics, Tokyo, Japan).
+ Open protocol
+ Expand
2

Cytotoxicity Evaluation of Hydroterpenes in RAW264.7 Macrophages

Check if the same lab product or an alternative is used in the 5 most similar protocols
A mouse RAW264.7 macrophage cell line (DS Pharma Biomedical Co., Ltd., Osaka, Japan) was
cultured in Dulbecco’s modified Eagle’s medium (Wako Pure Chemical Industries Ltd., Osaka,
Japan) containing 10% fetal bovine serum at 37°C in a humidified 5% CO2incubator.
The cells were added to 24-well plates (1 × 106 cells per well). Two hours
later, the medium was replaced with fresh medium to remove non-adherent cells. Fresh
medium containing serially diluted HT (0−50 µg/ml) was
added to the wells, and the cells were cultured at 37°C for 24 hr. The cytotoxicity of HT
was determined by measuring the amount of lactate dehydrogenase (LDH) released from the
cells using an automatic biochemical analysis system (LABOSPECT 006; Hitachi
High-Technologies Co., Ltd., Tokyo, Japan).
+ Open protocol
+ Expand
3

Nonhuman Primate Blood Chemistry Analyses

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood chemistry analyses were conducted in Pre, Pair_8W (8th week of Pair), and Single_8W
(8 or 9th week of Single).
For blood chemistry analyses, a blood sample was collected from the cephalic vein into
plastic tubes using a winged needle from 09:30 to 11:30 in Pre, Pair_8W, and Single_8W.
Blood collection was performed under manual restraint without anesthesia in front of the
animal’s home cage. The blood sample was allowed to clot and was centrifuged at 1,700 ×
g for 15 min at 4°C to separate the serum. Samples were analyzed using
an automatic analyzer (LABOSPECT 006, Hitachi High-Technologies Corporation, Tokyo,
Japan). The analyzed parameters were total protein, albumin, total bilirubin, total
cholesterol, triglyceride, alkaline phosphatase, aspartate transaminase, alanine
transaminase, glucose, urea nitrogen, creatinine, inorganic phosphorus, calcium, sodium,
potassium, and chloride.
+ Open protocol
+ Expand
4

Plasma Lipid Analysis for PCI

Check if the same lab product or an alternative is used in the 5 most similar protocols
Laboratory evaluations of plasma lipid and apolipoprotein levels were performed within two days before PCI. Commercial reagent kits (Determiner L TC II, Determiner L LDL-C II, Determiner L HDL-C II, and Determiner L TG II; Kyowa Medex, Tokyo, Japan) were used to analyze plasma TC, LDL-C, HDL-C, and triglyceride (TG) levels, and lipid concentrations were measured using an automated chemical analyzer (Labospect 006, Hitachi, Tokyo, Japan). Apo-B and Apo-A1 were measured by immunonephelometry, and high-sensitivity C-reactive protein (hs-CRP) levels were measured by nephelometry. Apolipoprotein levels were measured at a central clinical laboratory (SRL, Inc., Tokyo, Japan).
+ Open protocol
+ Expand
5

Comprehensive Laboratory Profiling of COVID-19

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood sampling was performed on the day of admission in hospitalized patients and throughout the clinical course in patients with severe disease. Total protein (TP), albumin, AST, lactate dehydrogenase (LDH), creatinine, and C-reactive protein (CRP) were measured by an Aqua-auto Kainos TP-II test, Aqua-auto Kainos ALB (Kainos, Tokyo, Japan), LaboFit AST, CicaFit LD-IFCC (Kanto Chemical Co., Inc., Tokyo, Japan), Signasu-auto CRE (Shino-test, Tokyo, Japan), and CRP-Latex X2 (Denka, Niigata, Japan), respectively, using a LABOSPECT006 (Hitachi High-Tech Co., Tokyo, Japan). PCT and ferritin were measured by Elecsys® BRAHMS PCT and Elecsys® Ferritin (Roche Diagnostics K.K., Tokyo, Japan), respectively, using a Cobas 8000 e602 (Roche Diagnostics K.K., Tokyo, Japan). The WBC count, hemoglobin (Hb), total neutrophil count, and total lymphocyte count were measured using a fully automatic blood cell counter XN-3000 (Sysmex Co., Kobe, Japan). HbA1c was measured using an Adams Hybrid AH 8280 (Arkray Factory, Shiga, Japan). The prothrombin time (PT), activated partial thromboplastin time (APTT), and D-dimer level were measured by a Thromborel S, Thrombocheck APTT-SLA, and LIASAUTO D-dimer Neo (Sysmex Co., Kobe, Japan), respectively, using an automatic coagulation analyzer CS-5100 (Sysmex Co., Kobe, Japan).
+ Open protocol
+ Expand
6

Albumin and Uric Acid Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The albumin and uric acid levels were measured using LAboSPECT006 (HITACHI, Tokyo) and the reagents Cica Liquid ALB and Cica Liquid UA (Kanto Chemical, Tokyo).
+ Open protocol
+ Expand
7

Precise Plasma BHB and Glucose Levels

Check if the same lab product or an alternative is used in the 5 most similar protocols
Precise plasma BHB levels were measured with LABOSPECT 006 (Hitachi, Ltd, Tokyo, Japan) using the Wako Autokit 3‐HB (FUJIFILM Wako Diagnostics, Lexington, MA, USA), which has high sensitivity and high specificity as it uses cyclic enzymatic reactions, according to the manufacturer’s standard protocol. Precise plasma glucose levels were measured with LABOSPECT 006 using the Aqua‐auto Kainos GLU (Kainos Laboratories Inc, Tokyo, Japan).
+ Open protocol
+ Expand
8

Plasma Lipid and Apolipoprotein Levels Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
Laboratory evaluations of plasma lipid and apo levels were conducted within 2 days before PCI. Commercial reagent kits (Determiner L TC II, L LDL-C II, L HDL-C II, and L TG II; Kyowa Medex, Tokyo, Japan) were used to analyze total plasma cholesterol, LDL-C, HDL-C, and TG levels. Lipid concentrations were measured using an automated biochemical analyzer (Labospect 006; Hitachi, Tokyo, Japan). Apo-C3 was measured in chylomicron-free samples, and apo-B and a were measured using immunonephelometry. High-sensitivity C-reactive protein levels were measured using nephelometry. Apo levels were measured at a central clinical biochemistry laboratory (SRL Inc., Tokyo, Japan).
+ Open protocol
+ Expand
9

Comprehensive Metabolic Assessment Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Each participant was present at the laboratory on the morning of the sampling day after fasting for 8–12 h. Each participant rested in a seated position prior to sampling. Blood sampling was performed by experienced laboratory technicians. Venous blood was collected into 5 mL serum separator tubes (Venoject II; Terumo, Tokyo, Japan) and 2 mL EDTA tubes (Venoject II; Terumo, Tokyo, Japan). EDTA samples immediately and serum tubes after 30 min in an upright position. All collection tubes were centrifuged at 3000× g for 10 min. Blood cell counts and hemoglobin A1c from EDTA samples were measured with an automated analyzer (Celltac G; Nihon Kohden, Tokyo, Japan). Levels of triglycerides, high-density lipoprotein cholesterol, total cholesterol, and uric acid were measured from serum using an automated analyzer (LABOSPECT006; Hitachi High-Tech Co., Tokyo, Japan). Systolic blood pressure and diastolic blood pressure were measured with the participants in the supine position. Height and body weight were measured with the participants wearing lightweight clothing. Global cognitive function was assessed by the Mini-Mental State Examination. The mean intima-media thickness of the common carotid artery was measured as an index of arteriosclerosis by sonography (Logiq 5; GE Healthcare, Little Chalfont, UK).
+ Open protocol
+ Expand
10

Albumin Concentration Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
The serum concentrations of albumin were determined with a LAboSPECT006 (HITACHI Ltd, Tokyo, Japan) using the reagent, CicaLiquid ALB (Kanto Chemical Co., Inc., Tokyo, Japan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.