The largest database of trusted experimental protocols

Biorad bioplex hts

Manufactured by Bio-Rad
Sourced in United States

The Bio-Rad Bioplex HTS is a high-throughput screening system designed for multiplex analysis. It utilizes magnetic beads coated with specific capture antibodies to simultaneously detect and quantify multiple analytes in a single sample. The system is capable of processing a large number of samples in a short time, making it a versatile tool for various applications in life science research and clinical diagnostics.

Automatically generated - may contain errors

3 protocols using biorad bioplex hts

1

Cytokine Profiling in Plasma Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The protein levels of various pro-inflammatory cytokines/chemokines; RANTES, IL-6, IL-8, monocyte chemotactic protein-1 (MCP-1), IL1-β, and TNF-α were measured using multiplex cytokine assay kit (Bio-Rad, CA, USA) as per the manufacturer’s protocol. Briefly, plasma samples were centrifuged at 3000 g for 10 min and the supernatants were diluted with three volumes of sample diluent. Next, 50 μl of each sample and standards were mixed with magnetic beads and incubated on a shaker at room temperature for 30 min. The beads were washed and 25 μl of detection antibody was added to each well followed by incubation for 30 min at room temperature. Furthermore, the samples were washed and incubated with 50 μl streptavidin-PE conjugate for 10 min. Finally, 125 μl of the assay buffer was added and the samples were analyzed using Biorad Bioplex HTS (Bio-Rad, CA, USA). The concentrations of the cytokines were determined with Bio-plex manager 5 using 5-PL statistics using standard curve.
+ Open protocol
+ Expand
2

Plasma Cytokine Profiling by Multiplex Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma levels of various pro-inflammatory cytokines/chemokines including RANTES, IL-6, IL-8, MCP-1, and TNF-α were measured as described previously [19 (link)] using the multiplex cytokine assay kit (Bio-Rad, CA, USA). Briefly, plasma samples were centrifuged and the supernatants were diluted with sample diluent (1:3). Next, 50 µl of each sample was used to determine the levels of these cytokines/chemokines using Biorad Bioplex HTS (Bio-Rad, CA, USA). The levels of cytokines were determined using the standard curve.
+ Open protocol
+ Expand
3

Inflammatory Cytokine Profiling in U937 and U1 Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cytokine production in U937 and U1 cells were measured using the human multiplex inflammatory cytokine assay kit (Bio-Rad, m50000007a, CA, USA). Cell culture supernatant was collected after 24 h of treatment. Three volumes of sample diluents were then added. Magnetic beads were added into 50 μL of samples or standards. The mixtures were incubated on a shaker at room temperature for 30 minutes. Streptavidin-PE conjugate (50 μL) was added after washes. After 10 minutes incubation, 125 μL of assay buffer was added. Samples were analyzed using Biorad Bioplex HTS (Bio-Rad, CA, USA). Bio-Plex manager 5 using 5-PL statistics was used to estimate cytokine concentrations.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!