Q exactive plus quadrupole orbitrap

Manufactured by Thermo Fisher Scientific
Sourced in Germany

The Q-Exactive Plus Quadrupole-Orbitrap is a high-resolution mass spectrometer that combines a quadrupole mass analyzer with an Orbitrap mass analyzer. It provides accurate mass measurements and high-resolution capabilities for analytical applications.

Automatically generated - may contain errors

3 protocols using q exactive plus quadrupole orbitrap

1

High-Resolution Mass Spectrometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
High-resolution mass spectrometry detection was performed on both Exactive Plus Orbitrap and Q-Exactive Plus Quadrupole-Orbitrap mass spectrometers (Thermo) equipped with an electrospray ionization source and operated in positive mode. Screening and confirmation of the substances were performed using full scan mode in Exactive Plus and parallel reaction monitoring (PRM) mode in Q-Exactive Plus. For identification of selected molecules, the scan range and collision energy were applied to each substance at a resolution of 35,000 in PRM mode.
+ Open protocol
+ Expand
2

Protein Denaturation, Reduction, and Digestion

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell lysates were washed with 8 M urea for protein denaturation, and dithiothreitol and iodoacetamide for cysteine reduction and alkylation, respectively. The proteins were subsequently digested with modified MS-grade trypsin (Pierce) at an enzyme/substrate ratio of 1:100 in 50 mM NH4HCO3 (pH 8.5) at 37 °C overnight. The resulting peptide mixture was dried in a Speed-vac, desalted with OMIX C18 pipet tips (Agilent Technologies), and analyzed by LC−MS and MS/MS on a Q Exactive Plus quadrupole-Orbitrap or a TSQ Vantage triple-quadrupole mass spectrometer (Thermo Fisher Scientific).
+ Open protocol
+ Expand
3

Optimized Oxidized Lipid Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Method development and optimization for analysis of oxidized complex lipids were performed using RP-UHPLC coupled on-line either to a Thermo Scientific Q Exactive Plus Quadrupole-Orbitrap (Thermo Fisher Scientific, Bremen, Germany) or Orbitrap Fusion Lumos Tribrid (Thermo Fisher Scientific, San Jose, USA) mass spectrometers.
Q Exactive Plus Quadrupole-Orbitrap was equipped with a HESI source and operated in both positive and negative ion modes with the following parameters: sheath gas—40 arb.units, auxiliary gas—10 arb.units, sweep gas—1 arb.units, spray voltage—+3.5 kV and −2.5 kV, capillary temperature—300 °C, S-lens RF level—35%, and aux gas heater temperature—370 °C.
Orbitrap Fusion Lumos Tribrid mass spectrometer using a HESI source was operated in both positive and negative ion modes with the following parameters: spray voltage—+3.5 kV and −2.8 kV, ion transfer tube temperature—250 °C, sheath gas—25 arb.units, aux gas—10 arb.units, vaporizer temperature—200 °C, RF level—25%.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!