The largest database of trusted experimental protocols

Myoglobin rat elisa kit

Manufactured by Abcam
Sourced in United States

The Myoglobin Rat ELISA Kit is a quantitative assay designed for the measurement of myoglobin levels in rat samples. This kit utilizes the enzyme-linked immunosorbent assay (ELISA) technique to detect and quantify the target analyte.

Automatically generated - may contain errors

2 protocols using myoglobin rat elisa kit

1

Quantifying Serum Biomarkers for Clinical Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum urea nitrogen (BUN), creatinine (Cr) and creatine kinase (CK) were analyzed by Hitachi 7170 automated biochemistry analyzer (Tokyo, Japan). Serum myoglobin was evaluated by ELISA using a Myoglobin Rat ELISA Kit (Abcam, Cambridge, USA) as follows: samples were diluted 1:3. Then, 100 μl of standards or samples was pipetted into the wells of a microtiter plate. The plate was incubated at room temperature for 60 min. After washing the plate, 100 μl of enzyme-antibody conjugate was pipetted into each well. The plate was then incubated in the dark at room temperature for 30 min. After washing the plate, 100 μl of TMB substrate solution was pipetted into each well. The plate was subsequently incubated in the dark at room temperature for 10 min. After that, 100 μl of stop solution was immediately added to each well. The absorbance (450 nm) of the contents of each well was measured by a microplate reader (Infinite F50, TECAN, Salzburg, Austria). A standard curve was drawn, and a four parameter algorithm equation was established by Magellan software (TECAN). The myoglobin concentration in each sample was then calculated by the software.
+ Open protocol
+ Expand
2

Serum Myoglobin Quantification by ELISA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Myo content was measured using the Myoglobin Rat ELISA kit (157739, Abcam, US) according to the manufacturer's instructions. Finally, the quantity of Myo in the serum was interpolated from the standard curve plotted from the standards and corrected for sample dilution.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!