The largest database of trusted experimental protocols

21 protocols using cosmosil 75c18 opn

1

Spectroscopic Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points were determined on a Yanaco Micro MP apparatus. Optical rotations were measured on a JASCO P-2100 polarimeter (Hachioji, Tokyo, Japan). Infrared spectra were recorded on JASCO FT/IR-460 Plus spectrometer. 1D and 2D NMR were carried out using Bruker Avance 500 spectrometer (Bruker, Mass., Billerica, MA) with tetramethylsilane as an internal standard. ESI-MS data including high-resolution mass spectrum were measured on Shimadzu LCMS-IT-TOF spectrometer (Kyoto, Japan) HREIMS was recorded on a JEOL MStation JMS-700 spectrometer (JEOL Ltd., Tokyo, Japan). Column chromatography was performed using silica gel (Kanto, 40–50 μm, Tokyo, Japan), Cosmosil 75C18-OPN (Nacalai Tesque Inc., Kyoto, Japan) and Sephadex LH-20 (Dowex® 50WX2-100, Sigma-Aldrich, Tokyo, Japan). Analytical TLC was performed on pre-coated silica gel 60F254 and RP-18 F254 plates (0.25 or 0.50 mm thickness, Merck KGaA, Darmstadt, Germany). Cosmosil 5C18-AR-II (Nacalai Tesque Inc., Kyoto, Japan) was used for analytical and semi-preparative HPLC (250 × 4.6 mm for analytical HPLC, and 250 × 10.0 mm for semi-preparative HPLC).
+ Open protocol
+ Expand
2

Spectroscopic Analysis of Natural Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotation values were determined using a JASCO P-1020 polarimeter. UV spectra were recorded using a Hitachi U-2900 spectrometer. ECD spectra were acquired with a JASCO J-820 spectropolarimeter and IR spectra were recorded using a Shimadzu FTIR-8400S spectrophotometer. NMR spectra were acquired with a JEOL JNM-ECZ 400S spectrometer with tetramethylsilane as an internal standard. ESI–MS data were obtained using an Agilent 6230 LC/TOF mass spectrometer. HPLC was performed on a Hitachi HPLC system equipped with an L-2130 pump, an L-2200 autosampler, an L-2300 column oven, and an L-2455 diode array detector. Silica gel AP-300 (Toyota Kako), Sephadex LH-20 (GE Healthcare), and Cosmosil 75C18-OPN (Nacalai Tesque) were used for column chromatography (CC). Silica gel 60 F254 and RP-18 F254S (Merck) were used for TLC analysis.
+ Open protocol
+ Expand
3

Isolation and Characterization of Grigescens

Check if the same lab product or an alternative is used in the 5 most similar protocols

G. rigescens was purchased from Huqingyutang Chinese Pharmacy Hangzhou, Zhejiang Province. The identity of this plant was confirmed by Associate Professor Liurong Chen (College of Pharmaceutical Sciences, Zhejiang University), and a voucher specimen (no. 20190620) was preserved in Zhejiang University, Institute of Materia Medica. Preparative high-performance liquid chromatography (HPLC) analysis was performed using a HPLC system equipped with Elite P-230 pumps (Dalian Elite Inc., China). An Agilent Technologies 6224A Accurate-Mass time-of-flight liquid chromatography–mass spectrometry (TOF LC/MS) system was used to measure the mass spectra (Agilent Technologies Inc., Beijing, China). A Bruker AV III-500 spectrometer was used to record the nuclear magnetic resonance (NMR) spectra (Bruker, Karlsruhe, Germany). NMR chemical shifts in δ (ppm) were referenced to solvent peaks of δC 49.0 for CD3OD (Cambridge Isotope Laboratories, Inc., MA, USA). Octadecyl-silane (Cosmosil 75 C18-OPN, Nacalai Tesque, Japan) and RP-18 plates (0.25 mm) (Merck KGaA, Darmstadt, Germany) were used for column chromatography and thin-layer chromatography analysis, respectively [2 (link)]. Resveratrol (Res) was purchased from J&K Scientific Ltd. (Beijing, China) and was used as a positive control.
+ Open protocol
+ Expand
4

Isolation and Characterization of Acer Saponin

Check if the same lab product or an alternative is used in the 5 most similar protocols
To evaluate the specificity of MAb 1E9 to AG, structurally similar compounds were required. Because AS [Fig. 1(B)] was commercially unavailable, it was isolated from S. japonica (powdered; Uchida Wakanyaku Co. Ltd., Tokyo, Japan). S. japonica (∼200 g) were soaked in methanol (500 mL), sonicated for 1 h, and filtered. This extraction step was repeated five times, and the filtrates (∼2.5 L) were then concentrated under vacuum to obtain ∼53.5 g of extracts. The extracts were dissolved in 50% (v/v) MeOH and partitioned with hexane. The aqueous layer was then partitioned with CHCl3, followed by ethyl acetate, to obtain an ethyl acetate fraction (∼4.3 g) containing AS. Reverse-phase chromatography using Cosmosil 75C18-OPN (Nacalai Tesque, Kyoto, Japan) with 50% (v/v) MeOH and silica gel 60 (0.063–0.200 mm; Merck, Darmstadt, Germany) chromatography with a mixture of CHCl3 and MeOH (CHCl3/MeOH = 8/2) was performed to obtain AS (∼210 mg). NMR spectra were recorded on a Varian Unity 500 plus apparatus (Varian, Palo Alto, CA, USA) operating at 500 MHz for 1H NMR and 125 MHz for 13C NMR in methanol-d4.
+ Open protocol
+ Expand
5

Characterization of Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
A JASCO P-1030 digital polarimeter was used for optical rotation measurements. Preparative high-performance liquid chromatography (HPLC) with a system equipped with ELITE P-230 pumps and a UV detector was used. High-resolution mass spectra (HR-ESI-TOF-MS) were obtained with an Agilent Technologies 6224A accurate mass TOF LC/MS system. NMR spectra were observed with Bruker AV III-500 spectrometer and NMR chemical shifts in δ (ppm) were referenced to solvent peaks of δC 77.0 and δH 7.26 for CDCl3. Column chromatography was performed by using silica gel (200–300 mesh, Yantai Chemical Industry Research Institute, Yantai, China) or reversed phase C18 (Octadecylsilyl, ODS) silica gel (Cosmosil 75C18-OPN, Nacalai Tesque, Kyoto, Japan).
+ Open protocol
+ Expand
6

Purification and Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Silica gel (200–300 mesh, Yantai Chemical Industry Research Institute, Yantai, China) and reversed-phase C18 open columns (Cosmosil 75 C18 OPN, Nacalai Tesque, Kyoto, Japan) were used for column chromatography. Pre-coated silica gel (0.25 mm) and RP-18 plates (0.25 mm) (Yantai Jiangyou Silicone Gel Development Co., Ltd., Yantai, China) were used for TLC analysis. Preparative high-performance liquid chromatography (HPLC, Eilite, Dalian, China) was conducted, equipped with two Elite-230 pumps, and a UV detector was used for purification. High-resolution electrospray ionization mass spectrometry (HR-MS) analysis was performed on Agilent 6224A accurate mass Time-of-Flight LC/MS system (Agilent Technologies, Santa, CA, USA). A Bruker AV III-500 spectrometer (Bruker, Billerica, MA, USA) was employed for NMR measurement. The 13C NMR chemical shifts in δ (ppm) referred to solvent chemical shifts of δC (150.350) for pyridine-d5.
+ Open protocol
+ Expand
7

Phytochemical Analysis and Isolation

Check if the same lab product or an alternative is used in the 5 most similar protocols
The chemical reagents used were of HPLC grade and purchased from TEDIA (Rhode Island, USA). The others were of analytical grade and obtained from Sinopharm Chemical Reagent Co. Ltd. (Shanghai, China). The preparative HPLC system was equipped with two ELITE P-230 pumps and an UV detector. Optical rotations were determined on a JASCO P-1030 digital polarimeter. High-resolution ESI-TOF-MS analyses were performed on an Agilent Technologies 6224A Accurate-Mass TOF LC/MS system (Santa Clara, CA, USA). Nuclear magnetic resonance (NMR) spectra were recorded on a Bruker AV III-500 spectrometer (Bruker, Billerica, MA, USA). Column chromatography was performed over the silica gel (200–300 mesh, Yantai Chemical Industry Research Institute, Yantai, China) or reversed phase C18 (Octadecylsilyl, ODS) silica gel (Cosmosil 75C18-OPN, Nacalai Tesque, Japan).
+ Open protocol
+ Expand
8

Preparative HPLC and Spectroscopic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Preparative HPLC analysis was performed using the HPLC system equipped with Elite P-230 pumps. The Agilent Technologies 6224A Accurate-Mass TOF LC/MS system was used to measure the mass spectra. For recording the NMR spectra, the Bruker AV III-500 spectrometer was used. NMR chemical shifts in δ (ppm) were referenced to solvent peaks of δC 49.0 and δH 3.30 for CD3OD. Silica gel (Qingdao Haiyang Chemical Co. Ltd., Qingdao, China) and octadecylsilane (Cosmosil 75 C18-OPN, Nacalai Tesque, Japan) were used for column chromatography. For TLC analysis, precoated silica gel (0.25 mm) and RP-18 plates (0.25 mm) were used. A JASCO P-1030 digital polarimeter was used to measure the optical rotations of the isolated compound.
+ Open protocol
+ Expand
9

Fractionation of sex-inducing substances

Check if the same lab product or an alternative is used in the 5 most similar protocols
A new fractionation method for sex-inducing substances was conducted as follows (Figure S5). Approximately 8 g wet weights of B. nobile and C. calicophorum were used. Each flatworm was homogenized in 480 mL of PBS (34 mM NaCl, 0.68 mM KCl, 2.5 mM Na2HPO4, and 0.45 mM KH2PO4; pH 7.4). The homogenate was centrifuged at 16,000 × g for 30min at 4°C. The supernatant was filtered using a 0.22 μm Millex®GV filter (Millipore, Carrigtwohill, Cork, Ireland) and then centrifuged at 120,000 × g for 30min at 4°C. It was subsequently freeze-dried and dissolved in water, yielding 100 mL of extract. The extract was further separated via open-column chromatography, using 50 g of ODS (COSMOSIL 75 C18–OPN, Nacalai Tesque, Kyoto, Japan) and an Econo-Column (50 φ × 500 mm, Bio-Rad, CA, USA). The substances absorbed in ODS were sequentially eluted using 0%, 10%, 30%, 50%, 70%, and 100% aqueous methanol to create 300 mL of Fr. M0, Fr. M10, Fr. M30, Fr. M50, Fr. M70, and Fr. M100, respectively. The obtained fractions were freeze-dried, and the resulting powders were used for feeding bioassays and HPLC analysis.
+ Open protocol
+ Expand
10

Analytical Techniques for Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical TLC was performed on silica gel 60F254 and RP-18F254S (Merck). Column chromatography was carried out on silica gel 60 (70–230 mesh, Merck) and COSMOSIL 75C18-OPN (Nacalai Tesque, Inc.). NMR spectra were recorded on JEOL ECA-600 and AL-400. Chemical shifts for 1H and 13C NMR are given in parts per million (δ) relative to tetramethylsilane (δH 0.00) and residual solvent signals (δC 77.0) as internal standards. Mass spectra were measured on JEOL JMS-700, JMS-DX303, and JMS-T 100 GC. Optical rotations were measured on JASCO P-1030.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.