The largest database of trusted experimental protocols

High molecular weight range gel filtration calibration kit

Manufactured by GE Healthcare
Sourced in Germany

The High molecular weight range gel filtration calibration kit is designed for the calibration of gel filtration or size exclusion chromatography columns. The kit contains a set of proteins with known molecular weights that can be used to establish a standard curve for the determination of the molecular weight of unknown protein samples.

Automatically generated - may contain errors

2 protocols using high molecular weight range gel filtration calibration kit

1

Native Protein Separation and Oligomeric State Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
The hrCN PAGE protocol was adapted from Lemaire et al. (2018) (link). Glycerol was added to the sample at a final amount of 20% (v/v). Ponceau S at a final concentration of 0.001% (w/v) served as a marker to follow the migration. The buffer composition for the electrophoresis cathode was the following: 50 mM tricine, 15 mM Bis-Tris/HCl, pH 7.0, 0.05% (w/v) sodium deoxycholate, 2 mM DTT, and 0.01% (w/v) dodecyl maltoside, whilst the anode buffer contained 50 mM Bis-Tris/HCl, PH 7.0, 2 mM DTT. An 8–15% linear polyacrylamide gradient gel was used, and electrophoresis was run under a N2/CO2 (90:10%) atmosphere with a constant 40 mA current (PowerPac Basic Power Supply, Bio-Rad). After electrophoresis, protein bands were visualised with Ready Blue Protein Gel stain (Sigma Aldrich, Hamburg, Germany). The native protein ladder used is NativeMark Unstained Protein Standard (Thermo Fischer Scientific, Driesch, Germany).
The determination of the oligomeric state by gel filtration was performed in triplicate on a Superose 6 Increase 10/300 GL (GE Healthcare, Munich, Germany) in 25 mM Tris/HCl pH 7.6, 2 mM DTT, 10% (v/v) glycerol at a flow rate of 0.4 ml/min, and in an anaerobic Coy tent containing an N2/H2 (97:3%) atmosphere. High molecular weight range gel filtration calibration kit (GE Healthcare, Munich, Germany) was used as the protein standard.
+ Open protocol
+ Expand
2

hrCN PAGE Protein Separation Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The hrCN PAGE protocol was adapted from Lemaire et al. (2018) [24 (link)] Glycerol was added to the sample at a final amount of 20% v/v. Ponceau S at a final concentration of 0.001% w/v served as a marker to follow the migration. The buffer composition for the electrophoresis cathode was the following: 50 mM Tricine, 15 mM Bis-Tris/HCl, pH 7, 0.05% w/v sodium deoxycholate and 0.01% w/v dodecyl maltoside, while the anode buffer contained 50 mM Bis-Tris/HCl buffer pH 7. A 5 to 15% linear polyacrylamide gradient gel was used and electrophoresis was run with a constant 40 mA current (PowerPacTM Basic Power Supply, Bio-Rad). After electrophoresis, protein bands were visualised with Ready BlueTM Protein Gel stain (Sigma Aldrich, Hamburg, Germany). The native protein ladder used is NativeMarkTM Unstained Protein Standard (ThermoFischer Scientific, Dreieich, Germany).
Determination of the oligomeric state by gel filtration was performed on a Superose6 Increase 10/300 GL (GE Healthcare, Munich, Germany) in 25 mM Tris/HCl pH 7.4, 2 mM DTT, 10% glycerol at a 0.4 mL/min flow rate. High Molecular Weight range Gel Filtration Calibration Kit (GE Healthcare, Munich, Germany) was used as the protein standard.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!