The largest database of trusted experimental protocols

2 protocols using 13c8 pfoa

1

Quantifying Perfluoroalkyl Substances in Solutions

Check if the same lab product or an alternative is used in the 5 most similar protocols
Calibration solutions were created by combining 2 solutions produced by the NIST reference materials 8446 Perfluorinated Carboxylic Acids and Perfluorooctane Sulfonamide in Methanol and 8447 Perfluorinated Sulfonic Acids in Methanol. Together, the solution contained 15 PFAAs as follows: PFBA, perfluoropentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), PFOA, perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnA), perfluorododecanoic acid (PFDoA), perfluorotridecanoic acid (PFTriA), perfluorotetradecanoic acid (PFTA), PFBS, perfluorohexanesulfonic acid (PFHxS), PFOS, and perfluorooctanesulfonamide (PFOSA).
Internal standards were purchased from Cambridge Isotope Laboratories, RTI International, and Wellington Laboratories to create an internal standard mixture comprised of 11 isotopically labeled PFAAs, as follows: 13C4-PFBA, 13C2-PFHxA, 13C8-PFOA, 13C9-PFNA, 13C9-PFDA, 13C2-PFUnA, 13C2-PFDoA, 18O2-PFBS, 18O2-PFHxS, 13C4-PFOS, and 18O2-PFOSA.
+ Open protocol
+ Expand
2

Quantification of Perfluorinated Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Calibration solutions were created by combining two solutions produced by the NIST Reference Materials (RMs) 8446 Perfluorinated Carboxylic Acids and Perfluorooctane Sulfonamide in Methanol and RM 8447 Perfluorinated Sulfonic Acids in Methanol. Together, the solution contained 15 PFAAs as follows: perfluorobutyric acid (PFBA), perfluoropentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), PFOA, PFNA, PFDA, perfluoroundecanoic acid (PFUnA), perfluorododecanoic acid (PFDoA), perfluorotridecanoic acid (PFTriA), perfluorotetradecanoic acid (PFTA), perfluorobutanesulfonic acid (PFBS), perfluorohexanesulfonic acid (PFHxS), PFOS, and perfluorooctanesulfonamide (PFOSA).
Internal standards (IS) were purchased from Cambridge Isotope Laboratories (Andover, MA), RTI International (Research Triangle Park, NC) and Wellington Laboratories (Guelph, Ontario) to create an IS mixture comprised of 11 isotopically labeled PFAAs, and they were as follows: 13C4-PFBA, 13C5-PFPeA, 13C5-PFHxA, 13C4-PFHpA, 13C8-PFOA, 13C9-PFNA, 13C6-PFDA, 13C7-PFUnA, 13C2-PFDoA (IS for PFDoA, PFTriA, and PFTA), 13C3-PFBS, 13C3-PFHxS, 13C8-PFOS, and 13C8-PFOSA.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!