The largest database of trusted experimental protocols

29 protocols using biflex 3

1

Synthesis and Characterization of Benzimidazole Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
Benzimidazole derivatives (BnzAc-OH, NBnzAc-OH, PBnzAc-OH and ClBnzAc-OH) were obtained by reacting t-butyl bromoacetate (1 eq) with an appropriate substrate (1.5 eq): benzimidazole, 2-nonylbenzimidazole, 2-(2-pyridyl) benzimidazole and 2-(2-chlorophenyl) benzimidazole in the presence of K2CO3 (1.2 eq) and catalytic amounts of tetrabutylammonium iodide (TBAI). Reactions were carried out in acetonitrile (ACN) for 20 h at 60 °C. After the syntheses had been completed, t-butyl groups were removed using 50% trifluoroacetic acid (TFA) in dichloromethane (DCM) for 2 h at room temperature. Crude products were purified by column chromatography on silica gel using methanol:ethyl acetate as the eluent. Fractions of the highest purity (>98%) were analyzed by an analytical reversed-phase high-performance liquid chromatography (RP-HPLC) system (Prominence, Shimadzu, Duisburg, Germany) using a Kinetex XB-C18 column (Phenomenex, 4.6 × 150 mm, 5 µm particle size) with several gradients of ACN with 0.08% TFA at a flow rate of 1 mL/min. Identities of compounds were confirmed by MALDI-TOF mass spectrometry (Bruker BIFLEX III, Bruker Daltonics, Billerica, MA, USA) using the α-CCA (α-cyano-4-hydroxycinnamic acid) matrix. Thus, the obtained benzimidazole derivatives (Figure 1) were attached on-resin to the ε-amino group of Lys7 residue within the TP10 structure.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Alkyne-Peptide Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
Solvents were dried using traditional methods, and freshly distilled prior to use. Reactions were monitored by thin-layer chromatography (TLC) on silica gel GF254-precoated plates and RP-HPLC (Agilent Technologies, Santa Clara, CA, USA). Compounds were detected under UV light and/or visualized by phosphomolybdic acid in ethanol solution. Solvents were evaporated under reduced pressure and below 50 °C. Mass spectra were obtained on Bruker APEX (Bruker Daltonics, Billerica, MA, USA). High-resolution MS (HRMS) were performed with Bruker BIFLEX III (Bruker Daltonics, Billerica, MA, USA) and Bruker APEX II (Bruker Daltonics, Billerica, MA, USA). 1H-NMR and 13C-NMR spectra were recorded on a BrukerAV400 (Bruker Biospin, Ettlingen, Germany) spectrometer or Bruker Avance III-HD 600 NMR Spectrometer (Bruker Biospin, Ettlingen, Germany) using TMS as internal standard. Chemical shifts are reported in parts per million and coupling constants quoted in Hz. Alkyne (a, b, c, d, e, f) CuSO4·5H2O, Sodium ascorbate and copper sheet from Alfa Aesar (Tianjin, China). Peptide 8 was purchased from GL Biochem (Shanghai, China) Ltd. Starting materials and copies of NMR spectrum of compound 6, 7a to 7i and 9 were put in the Supplementary Materials of this paper.
+ Open protocol
+ Expand
3

Bacterial Species Identification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Species identification of bacterial samples was confirmed by standard slide tests for the clumping factor and the 4-24 h tube test for free coagulase in rabbit-citrate-plasma (Becton and Dickinson; Heidelberg, Germany). S. aureus ATCC 33592 (MRSA; American Type Culture Collection, Wesel, Germany) and S. epidermidis DSM 20044 (German Collection of Microorganisms and cell cultures, Braunschweig, Germany) served as positive and negative controls. 16S rRNA amplification was performed as previously described (Herzner et al., 2011) . Both isolates were discriminated by spatyping (Koreen et al., 2004) using primers adapted to the sequence Routine mass spectrometry was performed on a VITEK MS mass spectrometer (BioMérieux, Marcy l'Etoile, France) equipped with the Myla software as described (Josten et al., 2014) . Preparation of extracts or smeared samples and MALDI-TOF MS for typing were performed on a Bruker Biflex III (Bruker Daltonik GmbH, Bremen, Germany) with cell extracts in the linear positive mode as previously described (Josten et al., 2013 (Josten et al., , 2014)) . Data was analysed using the flexAnalysis software (Bruker Daltonik GmbH, Bremen, Germany).
+ Open protocol
+ Expand
4

Synthesis and Characterization of Dysprosium Phthalocyanine Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
1,2,4-Trichlorobenzene (TCB) and dichloromethane were freshly distilled from CaH2 under nitrogen. Column chromatography was carried out on silica gel columns (Merck, Kieselgel 60, 70–230 mesh) with the indicated eluents. All other reagents and solvents were used as received. The compounds of {(Pc)Dy[Pc(OC5H11)8]} and {[Pc(OC5H11)8]Dy[Pc(OC5H11)8]} were prepared according to the published procedure.
1H NMR spectra were recorded on a Bruker DPX 400 spectrometer in CDCl3. Spectrum was referenced internally using the residual solvent resonances (δ = 7.26 for 1H NMR). MALDI-TOF mass spectra were taken on a Bruker BIFLEX III ultrahighresolution Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer with alpha-cyano-4-hydroxycinnamic acid as matrix. Elemental analyses were performed on an Elementar Vavio El III.
+ Open protocol
+ Expand
5

Characterization of Membrane Proteins

Check if the same lab product or an alternative is used in the 5 most similar protocols
2-D cryo-imaging was obtained using the FEI Tecnai microscope (FEI Company, Eindhoven, Netherlands). The peristaltic pump used was from Ismatec (Glattbrugg, Switzerland) and the Surface Plasmon Resonance RT2005 equipment was from Resonant Technologies GmbH (Germany). Proteins from the different yeast membrane fraction batches were quantified using the Pierce BCA Protein Assay kit (Thermo Scientific, USA) to obtain the Total Protein Concentration (TPC), and eluted c-myc-tagged OR, on a Nanodrop instrument (Labtech, UK). Protein bioconjugates were characterized by MALDI-TOF-MS (matrix assisted laser desorption ionization time-of-flight mass spectrometer) from Bruker Biflex III (Bruker, Karlsruhe, Germany). The washing steps in the ELISA assays were carried out using an ELx405 HT microplate washer (BioTek, Winooski, VT). The software packages used to read and analyze the ELISA results were SpectramaxPlus (Molecular Devices, Sunnyvale, CA) and GraphPad Prism v4.00 (GraphPad Software Inc., San Diego, CA). The olfactory receptor binding experiments were performed on a Biacore T100 instrument, GE Healthcare Bio-Sciences AB. All biosensor data processing and analysis was performed using Scrubber2 software (BioLogic Software). The AFM images were acquired with a MFP-3D AFM (Asylum Research) and analyzed using WSxM software (Nanotech, http://www.nanotec.es/).
+ Open protocol
+ Expand
6

Characterization of Naphthalyl-Amino Acid Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
3-(2-naphthyl)-D-alanine and 3-(2-naphthyl)-L-alanine were obtained from Aldrich and used as supplied without further purification. Q[8] was prepared according to a literature method39 (link)40 . All the 1H NMR spectra were recorded on a Bruker DPX 400 spectrometer in D2O. Absorption spectra of the host-guest complexes were recorded on an Aglient 8453 spectrophotometer at room temperature. Fluorescence spectra of the host-guest complexes were performed with a Varian RF-540 fluorescence spectrophotometer. MALDI-TOF mass spectrometry was recorded on a Bruker BIFLEX III ultra-high resolution Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer with a-cyano-4-hydroxycinnamic acid as matrix.
+ Open protocol
+ Expand
7

MALDI-TOF-MS Protocol using DHB and CCA

Check if the same lab product or an alternative is used in the 5 most similar protocols
The MALDI-TOF-MS spectra were recorded on the Bruker Biflex III company, (Branch Überlingen, Germany). 2,5-Dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (CCA) were used as a matrix.
+ Open protocol
+ Expand
8

Nanomaterial Characterization Techniques

Check if the same lab product or an alternative is used in the 5 most similar protocols
Scanning electron microscopy (SEM) images were collected using either a Nova NanoSEM 450 or a JEOL 6701F electron microscope operating at an accelerating voltage of 10 kV. UV-vis spectra were obtained using a Lambda 750S spectrometer. Matrix-assisted laser desorption-ionization time-of flight (MALDI-TOF) mass spectra were recorded with a Biflex III (Bruker Daltonics Inc., Germany) mass spectrometer using 1,1,4,4-tetraphenyl-1,3-butadiene as matrix in a positive ion linear mode. Cyclic voltammogram (CV) and differential pulse voltammogram (DPV) were measured in 1,2-dichlorobenzene (o-DCB) with 0.1 M of (n-Bu)4NPF6 as supporting electrolyte at a Pt working electrode with a CHI660E workstation.
+ Open protocol
+ Expand
9

Characterization of Photoinitiators by Analytical Techniques

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were recorded using a JOEL 600 MHz, and deuterated chloroform was used as the solvent. Mass spectra (MALDI) were acquired using a FT-ICR spectrometer (Bruker Daltonics Inc. BIFLEX III), acetonitrile was used as the solvent. UV-Vis absorption spectra and steady-state photolysis tests for COXEs were measured using a Shimadzu UV 3600, acetonitrile was used as the solvent and the PI concentration was 50 ppm. Fluorescence spectra were measured using a FLS980, acetonitrile was used as the solvent, and PI concentration was 50 ppm. LC-MS measurements were carried out by high-performance liquid chromatography (Agilent 1260) and quadrupole time-of-flight tandem mass spectrometry (Bruker micrOTOF-QII). The chromatographic separation was performed using a BetaBasic-18 column eluted with a mixture composed of 90% acetonitrile and 10% purified water at a flow rate of 0.3 mL·min−1; the monitoring wavelength was 254 nm; acetonitrile was used as the solvent.
+ Open protocol
+ Expand
10

Peptide Purification by RP-HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peptides were purified using a preparative reversed-phase high-performance liquid chromatography system (RP-HPLC) (Shimadzu, Kyoto, Japan) with a Jupiter Proteo column (4 μM, 90 Å, 250 × 10 mm) (Phenomenex, Torrance, CA, USA). The purity (>95%) of the peptides was determined using an analytical RP-HPLC system (Shimadzu, Kyoto, Japan) with a Jupiter Proteo column (4 μM, 90 Å; 250 × 4.6 mm) (Phenomenex, Torrance, CA, USA) and the linear gradient of solution B in A from 5% to 95% over 30 min with a flow rate of 1 mL/min. The eluents used were as follows: A—0.1% aqueous solution of TFA and B—80% solution of acetonitrile in aqueous 0.1% TFA (v/v). The mass spectra of the peptides were recorded using a Bruker BIFLEX III and autoflex maX MALDI TOF mass spectrometers or for NT-14 only by mass spectrometry with an ESI LCMS IT TOF device (Shimadzu, Kyoto, Japan). A linear gradient solution B was applied as a mobile phase.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!