The largest database of trusted experimental protocols

Shr 7700

Manufactured by Hamamatsu Photonics
Sourced in Japan

The SHR-7700 is a high-resolution spectroradiometer designed for accurate measurement of optical radiation. It features a high-sensitivity silicon photodiode detector and a precision monochromator to provide detailed spectral data over the 350 to 1100 nm wavelength range.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using shr 7700

1

Nasal Delivery of [18F]-PspA Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Because the half-life of [18F] is only 110 min, we used the same naive macaque for nasal [18F]-PspA-nanogel or [18F]-PspA-PBS administration with a 1-week interval between administrations. After nasal administration of 50 MBq per 700 μl of [18F]-PspA-nanogel or [18F]-PspA-PBS (350 μl in each nostril), the macaque's head was tilted back for 10 min and then scanned in an upright position. PET scans were conducted for 345 min with frames of 25 × 3 min, followed by 27 × 10 min, with the use of a high-resolution animal PET scanner (SHR-7700; Hamamatsu Photonics, Shizuoka, Japan). MRI images were recorded with Signa Excite HDxt (3T; GE Healthcare) to identify the cerebrum regions.
+ Open protocol
+ Expand
2

Primate PET Imaging of Brain Function

Check if the same lab product or an alternative is used in the 5 most similar protocols
After overnight fasting, monkeys were tracheostomized, immobilized with pancuronium bromide (0.05 mg/kg intramuscularly), and artificially ventilated (Cato; Drager). Anesthesia was continued with 0.4-0.8 vol% isoflurane in a N 2 O/O 2 /N 2 (1:1:1) gas mixture. A venous cannula for PET probe injection and an arterial cannula for blood sampling (only for 18 F-BCPP-EF measurements) were inserted in both inferior limbs. The animal's head was set in a supine position on a bed with stereotactic coordinates aligned parallel to the orbitomeatal line plane. In PET measurements using b-11 C-L-DOPA, 18 F-FDOPA, and 11 C-6MemTyr, carbidopa, an inhibitor of peripheral aromatic L-amino acid decarboxylase, was administered at a dose of 5 mg/kg, by mouth, 1 h before each PET probe injection. After a transmission scan, emission scans were obtained for 91 min after the injection of each PET probe using an animal PET scanner (SHR-7700; Hamamatsu Photonics) (15) . PET data were reconstructed by the filtered backprojection method, and individual PET and MR images were coregistered. Volumes of interest in brain regions were drawn manually on MR images by referring to regional information from BrainMaps.org (16) .
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!