Manufactured by Bruker

The MaXis HUR-QToF system is a high-resolution quadrupole time-of-flight mass spectrometer designed for accurate mass measurements and high-throughput analysis. It features a high-performance quadrupole mass filter and a time-of-flight analyzer to provide precise mass determination and enhanced sensitivity.

Automatically generated - may contain errors

5 protocols using maxis hur qtof system

1

LC-ESI-MS Analysis of Methylglyoxal Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
The LC-ESI-MS system consisted of an ultra-performance liquid chromatography (UPLC) system (Ultimate 3000 RSLC, Dionex) and an electrospray ionization (ESI) source of quadrupole time-of-flight (TOF) mass spectrometer (maXis HUR-QToF system, Bruker Daltonics). The autosampler was kept at 4 °C. Separation was performed with reversed-phase liquid chromatography (RPLC) on a BEH C18 column (2.1×100 mm, Walters). The elution started from 99% mobile phase A (0.1% formic acid in ultrapure water) and 1% mobile phase B (0.1% formic acid in acetonitrile), raised to 90% B in 1 min, held at 90% B for 2 min, and then lowered to 1% B in 0.5 min. The column was equilibrated by pumping 1% B for 3.5 min. The flow rate was set at 0.4 ml/min with per injection volume 10 μl. LC-ESI-MS chromatogram were acquired under the following conditions: capillary voltage of 4500 V in positive ion mode, dry temperature at 190 °C, dry gas flow maintained at 8 l/min, nebulizer gas at 1.4 bar, and acquisition range of m/z 100–1000. Reaction products of methylglyoxal and 2,3-diaminopyridine gave rise to signals of at least 6-fold intensity as compared with that of methylglyoxal and o-phenylenediamine in mass spectrometry detection.
+ Open protocol
+ Expand
2

Untargeted Metabolite Profiling by LC-ESI-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
In vitro materials were ground with liquid nitrogen and mixed with 1 mL of methanol. Supernatant was collected by centrifugation (12000 rpm, 1 min). The LC-ESI-MS system consisted of an ultra-performance liquid chromatography system (Ultimate 3000 RSLC, Dionex) and an electrospray ionization source of quadrupole time-of-flight mass spectrometer (maXis HUR-QToF system, Bruker Daltonics). The autosampler was set at 4°C. Separation was performed with reversed-phase liquid chromatography on a BEH C8 column (2.1 × 100 mm, Walters). The elution started from 99% mobile phase A (0.1% formic acid in ultrapure water) and 1% mobile phase B (0.1% formic acid in ACN), held at 1% B for 1.5 min, raised to 60% B in 6 min, further raised to 90% in 0.5 min, and then lowered to 1% B in 0.5 min. The column was equilibrated by pumping 1% B for 4 min. The flow rate was set to 0.4 mL/min with an injection volume of 5 μL. LC-ESI-MS chromatogram were acquired under the following conditions: capillary voltage of 4500 V in positive ion mode, dry temperature of 190°C, dry gas flow maintained at 8 L/min, nebulizer gas at 1.4 bar, and acquisition range of m/z 100–1000.
+ Open protocol
+ Expand
3

Extraction and LC-ESI-MS Analysis of Plant Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
The extraction was carried out by adding 40 μL of 100% DMF to 1 mg of the dry plant powder with vortexing for 30 min. After centrifugation at 16,000 × g for 10 min, the supernatant was collected for LC-ESI-MS analysis. The LC-ESI-MS system consisted of an ultra-performance liquid chromatography (UPLC) system (Ultimate 3000 RSLC, Dionex) and an electrospray ionization (ESI) source of quadrupole time-of-flight (TOF) mass spectrometer (maxis HUR-QToF system, Bruker Daltonics). The autosampler was set at 4°C. Separation was performed with reversed-phase liquid chromatography (RPLC) on a BEH C8 column (2.1 × 100 mm, Walters). The elution started from 50% mobile phase A (0.1% formic acid in deionized water) and 50% mobile phase B (0.1% formic acid in ACN), raised to 60% B in 2 min, further increased to 75% after an additional 1 min, and then raised to 100% B in 4.5 min, held at 100% B for 2.5 min, and then lowered to 50% B during the final 1 min. The column was equilibrated by pumping 50% B for 4 min. The flow rate was set 0.4 mL/min with an injection volume of 2 μL. LC-ESI-MS chromatogram was acquired in positive ion mode under following conditions: capillary voltage of 4500 V, dry temperature at 190°C, dry gas flow maintained at 8 L/min, nebulizer gas at 1.4 bar, and acquisition range of m/z 100–1000.
+ Open protocol
+ Expand
4

Cysteine Reaction Kinetics Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
In 1 ml of solution containing 100 μM cysteine, 100 μM PVS, PVSN, or Bay 11-7082 in 20 mM NaHCO3, pH 8.4, reaction was held at 37°C for 60 min. The resulting reaction products were subjected directly to the LC–ESI–MS analyses. The LC–ESI–MS system consisted of an ultra-performance liquid chromatography system (Ultimate 3000 RSLC, Dionex) and an electrospray ionization (ESI) source of quadrupole time-of-flight (TOF) mass spectrometer (maXis HUR-QToF system, BrukerDaltonics). The samples were kept in an autosampler at 4°C. Separation was performed with reversed-phase liquid chromatography (RPLC) on a BEH C18 column (2.1 × 100 mm, Walters). The elution started from 99% mobile phase A (0.1% formic acid in ultrapure water) and 1% mobile phase B (0.1% formic acid in ACN), held at 1% B for 0.5 min, raised to 60% B in 6 min, further raised to 90% B in 0.5 min, held at 90% B for 1.5 min, and then lowered to 1% B in 0.5 min. The column was equilibrated by pumping 1% B for 4 min. The flow rate was set 0.4 ml/min with injection volume of 2 μl. LC–ESI–MS chromatogram were acquired under following conditions: capillary voltage of 4500 V in positive ion mode, dry temperature at 190°C dry gas flow maintained at 8 l/min, nebulizer gas at 1.4 bar, and acquisition range of m/z 100–1000.
+ Open protocol
+ Expand
5

Cucurbitacin Quantification via LC-ESI-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
In vitro materials were ground with liquid nitrogen and mixed with 1 mL of methanol. Supernatant was collected by centrifugation (12000 rpm, 1 min). The LC-ESI-MS system consisted of an ultra-performance liquid chromatography system (Ultimate 3000 RSLC, Dionex) and an electrospray ionization source of quadrupole time-of-flight mass spectrometer (maXis HUR-QToF system, Bruker Daltonics). The autosampler was set at 4 °C. Separation was performed with reversed-phase liquid chromatography on a BEH C8 column (2.1 × 100 mm, Walters). The elution started from 99 % mobile phase A (0.1 % formic acid in ultrapure water) and 1 % mobile phase B (0.1 % formic acid in ACN), held at 1 % B for 1.5 min, raised to 60 % B in 6 min, further raised to 90 % in 0.5 min, and then lowered to 1 % B in 0.5 min. The column was equilibrated by pumping 1 % B for 4 min. The flow rate was set to 0.4 mL/min with an injection volume of 5 μL. LC-ESI-MS chromatogram were acquired under the following conditions: capillary voltage of 4500 V in positive ion mode, dry temperature of 190 °C, dry gas flow maintained at 8 L/min, nebulizer gas at 1.4 bar, and acquisition range of m/z 100–1000. Five samples for each condition were independently measured for cucurbitacin content levels.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!