3 protocols using il 17e

1

Quantifying Inflammatory Mediators in PICF/GCF

Check if the same lab product or an alternative is used in the 5 most similar protocols
The PICF/GCF samples were eluted from paperstrips into 500 µl PBS by vortexing the sample vigorously for 30 sec, the paperstrip was removed and microorganisms in the sample were pelleted by centrifugation at 14 000 g for 10 min and the supernatant was transferred to a clean tube.
Measurement of RANKL, OPG, IL-1, IL-17A, IL-17E levels in PICF/GCF samples Commercial ELISA kits were purchased for the measurement of OPG (R&D Systems Abingdon, UK), sRANKL, IL-17A, IL-17E (Peprotech London, UK), IL-1 (Thermo Fisher Paisley, UK). The ELISA assays were carried out according to the manufacturers' recommendations. The optical densities were read at 450 nm with a background subtraction at 570 nm and the samples were compared with the standards. The minimum detection limits for the assays were as follows OPG: 7.56pg/ml; RANKL: 7.56 pg/ml; IL-17A, IL-17E: 0.79 pg/ml; IL-1: 0.79 pg/ml. The PICF/GCF data were expressed as total amounts per sampling time (pg/30sec) and also as concentrations (pg/µl).
+ Open protocol
+ Expand
2

Quantification of Inflammatory Cytokines

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercial ELISA kits were purchased for the measurement of TNF-α, IL-6, IL-10, IL-17A, IL-17F, IL-17E (Peprotech London UK), IL-17A/F (R & D systems Abingdon UK). The ELISA assays were carried out according to the manufacturers' recommendations. The optical densities of each well were read at 450 nm with a background subtraction at 570 nm and the samples were compared with the standards. The minimum detection limits for the assays were; TNF-α 0.4 pg/mL, IL-6, IL-10, IL-17A, IL-17F, IL-17E, 0.79 pg/mL, IL-17A/F 1.59 pg/mL. The GCF data were expressed as total amounts per sampling time (pg/30s) and also as concentrations (pg/µL). The findings in saliva and serum samples were expressed as concentrations (pg/mL).
+ Open protocol
+ Expand
3

Cytokine Profiling in Gingival Crevicular Fluid

Check if the same lab product or an alternative is used in the 5 most similar protocols
Enzyme-linked immunosorbent assay and specific kits for IL-1β, IL-6, IL-10, TNF-α, IL-17A, IL-17E (Pepro Tech, London UK), TGF-β (Mabtech AB, Stockholm Sweden) were used for cytokines measurement in GCF. Minimum detection limits were: IL-1β, IL-6, IL-10, TNFα and IL-17A, all 1.9pg/ml; IL-17E and TGF-β, both 3.9pg/ml.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!