The largest database of trusted experimental protocols

3 protocols using butvar solution b 98

1

Structural Analysis of CF-H-AuNPs and CF-H-PtMPs

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Scanning Electron Microscope (SEM-microanalyser REMMA-102-02, Sumy) was used for structural and morphological analysis of the CF-H-AuNPs and CF-H-PtMPs. The micro/nanocomposites were immersed in a Butvar solution B-98 (Sigma-Aldrich) in 1.5% chloroform and ultrasonicated. All the used parameters, WD—distance from the last lens of a microscope to the samples (mm); kV—accelerating voltage; х—magnification fold; and scale unit (μm), are indicated in the corresponding SEM microphotographs.
+ Open protocol
+ Expand
2

Enzyme-Linked Immunosorbent Assay (ELISA) Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Horseradish peroxidase (HRP) (EC 1.11.1.7, from Armoracia rusticana, 500 U·mg−1), tetrachloroauric acid trihydrate, sodium salt of ABTS, sodium citrate, N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride (EDC), pentafluorophenol (PFP), 2-(2-aminoethoxy) ethanol (AEE), dimethylformamide (DMF), N,N-diisopropylethylamine (DIPEA), 16-mercaptohexadecanoic acid (MHDA), methylamine (MA), dimethylamine (DMA), trimethylamine (TMA), NaCl, KH2PO4, Na2HPO4, chloroform, and Butvar solution B-98 were purchased from Sigma-Aldrich (ALSI Ltd., Kiev, Ukraine). The cathodic electrodeposition paint “GY 83–0270 0005” was from BASF Farben und Lacke (Munster, Germany). All buffers and standard solutions were prepared using the water purified by the Milli-Q system (Millipore).
+ Open protocol
+ Expand
3

Scanning Electron Microscopy of Electrode Surfaces

Check if the same lab product or an alternative is used in the 5 most similar protocols
A scanning electron microscope (SEM-microanalyser REMMA-102-02, Sumy, Ukraine) was used for morphological characterization of the electrodes’ planar surfaces. A special cover film was formed on the samples with a Butvar solution B-98 (Sigma, St. Louis, MO, USA) in 1.5% chloroform using an ultrasound method. The distance from the last lens of the microscope to the sample (WD) ranged from 17.1 to 21.7 mm. The accelerator voltage was in the range from 20 to 40 kV. Zooms were from 2500× to 10,000×.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now