The largest database of trusted experimental protocols

Omnitip plastic homogenizer probes

Manufactured by Omni International
Sourced in United States

The OmniTip Plastic Homogenizer Probes are a set of plastic probes designed for use with homogenizer devices. The probes are made of a durable plastic material and are intended to facilitate the homogenization of samples in research and laboratory settings.

Automatically generated - may contain errors

3 protocols using omnitip plastic homogenizer probes

1

CFU Enumeration in Infected Cells and Tissues

Check if the same lab product or an alternative is used in the 5 most similar protocols
For CFU enumeration in in vitro infected cells, cells were lysed with 500μl sterile H2O for five minutes, followed by addition of 500μl PBS supplemented with 0.05% Tween80. For CFU enumeration in tissues, organs were homogenized in 1ml 7H9 broth (BD) supplemented with 0.2% glycerol (Wisent), 0.05% Tween80 (Fisher), and 10% ADC using OmniTip Plastic Homogenizer Probes (Omni International). Serial dilutions in PBS+0.05% Tween80 were plated on 7H10 agar plates with 10% OADC enrichment and PANTA (BD). Plates were then incubated at 37°C and counted after 21 days.
+ Open protocol
+ Expand
2

CFU Assay of Lung and Spleen Tissues

Check if the same lab product or an alternative is used in the 5 most similar protocols
For CFU assay in tissues, tissues of lung and spleen from sacrificed mice were homogenized in 1 mL 7H9 broth (BD) supplemented with 2 g/L sodium pyruvate, 0.05% Tween 80, and 10% OADC using OmniTip Plastic Homogenizer Probes (Omni International, Bedford, MA, USA). Serial dilutions in PBS + 0.05% Tween 80 were plated on 7H10 agar plates supplemented with OADC (10%), amphotericin B (10 µg/mL) and polymyxin B sulfate (10 µg/mL). Plates were then incubated at 37 °C and the number of CFU was counted after 3 weeks.
+ Open protocol
+ Expand
3

Aerosol Mtb Infection in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mice were either infected with ∼50 CFU of Mtb (H37Rv) in a nose-only aerosol exposure unit (Intox) 7 days after the first administration of β-glucan and survival was monitored. Infection dose was confirmed by enumerating the lung CFU one day after infection. For CFU enumeration, lungs were homogenized in 1 mL 7H9 broth (BD) supplemented with 0.2% glycerol (Wisent), 0.05% Tween80 (Fisher), and 10% ADC using OmniTip Plastic Homogenizer Probes (Omni International). Serial dilutions in PBS+0.05% Tween80 were plated on 7H10 agar plates with 10% OADC enrichment and PANTA (BD). Plates were then incubated at 37°C and counted after 21 days.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!