The largest database of trusted experimental protocols

Infinity cholesterol tr13421

Manufactured by Thermo Fisher Scientific

The Infinity cholesterol (TR13421) is a laboratory reagent designed for the quantitative determination of total cholesterol levels in biological samples. It is a colorimetric assay that utilizes the enzymatic hydrolysis and oxidation of cholesterol to produce a colored complex, which is measured spectrophotometrically.

Automatically generated - may contain errors

3 protocols using infinity cholesterol tr13421

1

Serum Biomarker Profiling in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of ALT and AST were determined using the MaxDiscovery ALT (3460-08) and AST (5605-01) Assay Kits (Bioo-Scientific, Austin, TX). Plasma or tissue fatty acids, triglyceride and cholesterol were determined using the Infinity Cholesterol (TR13421) and Triglyceride (TR22421) Reagents (Thermo Scientific, Waltham, MA). Serum level of Lcn2 was measured by Lipocalin-2/ab199083 Mouse ELISA Kit (Abcam, Cambridge, MA). Serum level of Saa1 was measured by Saa1/ab157723 Mouse Elisa Kit (Abcam, Cambridge, MA). Serum level of FGF15 was measured by FGF15/LS-F11446 Mouse Elisa Kit (LifeSpan BioSciences, Inc, Seattle, WA). Serum levels of total adiponectin were determined using a commercial ELISA kit from BioVendor (Candler, NC). Serum levels of HMW forms of adiponectin were determined with Mouse Adiponectin Assay Kit from ALPCO # 47-ADPMS-E01 (Salem, NH). Concentrations of total bile acids in serum were determined using a 3α-hydroxysteroid dehydrogenase method (Diazyme). Analyses were performed with a SpectraMax i3x microplate reader (Molecular Devices, Sunnyvale, CA).
+ Open protocol
+ Expand
2

Equine Plasma Lipid Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma triglycerides and cholesterol concentrations were measured with an enzymatic assay (Konelab i 20XTi, Thermo Electron Corp., Waltham, MA) using commercially available reagents [Infinity cholesterol (TR13421) and triglyceride (TR22421) reagents, Thermo Fisher, Waltham, MA] and standards [Stabio cholesterol standard (SB1012030), Thermo Fisher, Waltham, MA; triglyceride standard (T7531STD), Pointe Scientific, Canton, MI]. Plasma HMW adiponectin was measured using a commercially available kit (EZHWAM-65, Millipore Sigma, Burlington, MA) previously validated for use in lean and obese horses (22 (link)). Average intra-assay variation for plasma adiponectin was 3.14%.
+ Open protocol
+ Expand
3

Lipoprotein Separation and Cholesterol Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lipoprotein separation for total cholesterol and triglycerides estimation in plasma samples was performed using fast-protein liquid chromatography (FPLC) as described elsewhere (27 (link)). Briefly, mice were fasted 4 h, and blood was collected in anticoagulant (EDTA)-coated tubes through the submandibular plexus. Samples were centrifuged at 2500 g for 10 min at 4°C, and plasma was collected and the total cholesterol was measured (using an enzymatic kit) to ensure that pooling of samples used plasma with comparable sterols to exclude any outliers with any dramatic differences between individual mice (although no samples needed to be excluded). Column chromatography (10/300GL, Superose 6) was then used for separation of different lipoproteins by loading a minimum of 100 μl of pooled plasma mixed with 100 μl of PBS, from each group, onto the Akta pure FPLC, and a total of 52 fractions each with volume of 500 μl were collected and analyzed for cholesterol content using Infinity cholesterol (TR13421) and triglyceride (TR22421) calorimetric kits procured from ThermoFisher Scientific, Middletown, VA.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!