The largest database of trusted experimental protocols

Toyopearl hw 65s

Manufactured by Tosoh
Sourced in United States

Toyopearl HW-65S is a size exclusion chromatography resin. It is designed for the separation and purification of biomolecules based on their size and molecular weight.

Automatically generated - may contain errors

2 protocols using toyopearl hw 65s

1

Monodispersed Bead-Containing Droplet Formation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Rigid 20–40 μm beads made from hydroxylated methacrylic polymer (Toyopearl HW-65S, Tosoh Bioscience) are used to demonstrate the formation of monodispersed bead-containing droplets at limiting dilution. Beads are suspended in 68% OptiPrep DensityGradient Medium (Sigma-Aldrich), and co-flowed with 2% agarose (Ultra-low Gelling Temperature Agarose, Type IX-A, Sigma-Aldrich) in 1× PBS. The device, identical to one previously described,1 (link) is fabricated at a height of 100 μm. Flow rates are 2000 μl h–1 bead-containing solution, 2000 μl h–1 agarose, and 40 000 μl h–1 2% ionic Krytox, prepared as previously described.18 (link)
+ Open protocol
+ Expand
2

Antioxidant Capacity of Pediococcus Exopolysaccharides

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pediococcus pentosaceus MYU 759 was propagated at 37°C for 24 hr using one liter of MRS broth. An equal volume of 99.5% cold ethanol (Kanto Chemical Co., Inc.) was added to
the supernatant after centrifugation (1,500 × g, 15 min, 4°C), and the mixture was allowed to stand at 4°C overnight, followed by centrifugation (12,200 × g, 30 min, 4°C) to obtain a
precipitate. After treatment with 10% trichloroacetic acid, the sugar fraction was obtained by ethanol precipitation. Next, it was applied to DEAE-TOYOPEAL 650 M (Tosoh Bioscience, King of
Prussia, PA, USA) followed by TOYOPEARL HW-65S (Tosoh Bioscience). The fractions with a high sugar content were dialyzed against distilled water at 4°C for 2 days and then lyophilized. The
purified EPSs were dissolved with assay buffer (0.125, 0.25, and 0.5 mg/ml), and the antioxidant capacity was measured by the ORAC and HORAC methods. The data were indicated as the Trolox
equivalent antioxidant capacity (TEAC; μM TE) and gallic acid equivalent antioxidant capacity (GAEAC; μM GAE).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!