The largest database of trusted experimental protocols

Perfecta fastmix 2 low rox kit

Manufactured by Quanta Biosciences

The PerfeCTa FastMix II Low ROX kit is a ready-to-use reaction mix for real-time quantitative PCR (qPCR) applications. It contains a proprietary buffer system, stabilizers, and a chemically-modified hot-start DNA polymerase for reliable and sensitive amplification of target sequences.

Automatically generated - may contain errors

2 protocols using perfecta fastmix 2 low rox kit

1

Quantifying Viral DNA in EV Fractions

Check if the same lab product or an alternative is used in the 5 most similar protocols
200 μl aliquots of EV fraction, intermediate fraction, and HCMV fraction were subjected to nucleic acid extraction using a NucliSENS easyMAG 2.0 instrument (BioMérieux, Durham, NC). Quantitative real-time PCR (qPCR) was performed with a PerfeCTa FastMix II Low ROX kit (Quanta BioSciences, Gaithersburg, MD) using the following primer set: HHV-5 FWD: AACCAAGATGCAGGTGATAGG, HHV-5 REV: AGCG TGACGTGCATAAAGA, and the probe: /56-FAM/TACCTGGAG/ZEN/ TCCTTCTGCGAGGA/3IABkFQ/. Amplifications were carried out on a BioRad CFX96 Touch Thermocycler according to the following cycling parameters: 2 min at 95 °C followed by 44 cycles of 10 s at 95 °C and 30 s at 60 °C.
+ Open protocol
+ Expand
2

Quantifying Viral DNA in EV Fractions

Check if the same lab product or an alternative is used in the 5 most similar protocols
200 μl aliquots of EV fraction, intermediate fraction, and HCMV fraction were subjected to nucleic acid extraction using a NucliSENS easyMAG 2.0 instrument (BioMérieux, Durham, NC). Quantitative real-time PCR (qPCR) was performed with a PerfeCTa FastMix II Low ROX kit (Quanta BioSciences, Gaithersburg, MD) using the following primer set: HHV-5 FWD: AACCAAGATGCAGGTGATAGG, HHV-5 REV: AGCG TGACGTGCATAAAGA, and the probe: /56-FAM/TACCTGGAG/ZEN/ TCCTTCTGCGAGGA/3IABkFQ/. Amplifications were carried out on a BioRad CFX96 Touch Thermocycler according to the following cycling parameters: 2 min at 95 °C followed by 44 cycles of 10 s at 95 °C and 30 s at 60 °C.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!