The largest database of trusted experimental protocols

4 chlorobenzenesulfonate salt

Manufactured by Thermo Fisher Scientific
Sourced in United States

4-chlorobenzenesulfonate salt is a chemical compound used as a reagent in laboratory settings. It serves as a precursor for various synthetic reactions and analysis techniques. The compound provides a source of the 4-chlorobenzenesulfonate ion, which can be utilized in research and development applications.

Automatically generated - may contain errors

3 protocols using 4 chlorobenzenesulfonate salt

1

Fluorescent Labeling of Cell Membranes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemicals including chitosan oligosaccharide lactate (Mw = 5000), dithiothreitol (DTT), and acetone were purchased from Sigma-Aldrich. Fluorophores including 1,1’-dioctadecyl-3,3,3’,3’-tetramethylindodicarbocyanine, 4-chlorobenzenesulfonate salt (DiD, excitation/emission = 644/665 nm) and 3,3’-dioctadecyloxacarbocyanine perchlorate (DiO, excitation/emission = 484/501 nm) were purchased from ThermoFisher Scientific. Poly (lactic-co-glycolic) acid (PLGA, 50:50, 0.67 dL/g) was purchased from LACTEL Absorbable Polymers. Packed human red blood cells (RBCs) were purchased from ZenBio, Inc., from which cell membrane was derived according to a previously published protocol.[14 (link)]
+ Open protocol
+ Expand
2

Lipid Probes for Membrane Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The lipids DOPC, 1,2-dioleoyl-sn-glycero-3-phosphoethanolamine (DOPE), DOPS, 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine-N-[4-(p-maleimidomethyl)cyclohexane-carboxamide] (16:0 MCC-PE), and 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[biotinyl(polyethylene glycol)-2000] (DSPE-PEG-Biotin) were obtained from Avanti Polar Lipids (Alabaster, AL). Alexa Fluor 488 SDP ester, Alexa Fluor 594 C5 maleimide, and the lipid fluorophore 1,1'-dioctadecyl-3,3,3',3'-tetramethylindodicarbocyanine, 4-chlorobenzenesulfonate salt (DiD), and BODIPY-FL-DHPE (N-(4,4-Difluoro-5,7-Dimethyl-4-Bora-3a,4a-Diaza-s-Indacene-3-Propionyl)-1,2-Dihexadecanoyl-sn-Glycero-3-Phosphoethanolamine, Triethylammonium Salt) were from ThermoFisher Scientific (USA). Streptavidin-conjugated microsphere beads (6 μm diameter) were from Polysciences (Warrington, PA). All common reagents used for the buffer preparation, such as HEPES, Tris, NaCl, Na2HPO4, NaH2PO4, ethylenediaminetetraacetic acid (EDTA), and dithiothreitol (DTT), were from Fisher Scientific (USA). β-casein from bovine milk was obtained from Sigma-Aldrich (USA). Unless otherwise specified, all chemicals from commercial sources were used without further purification.
+ Open protocol
+ Expand
3

Lipid Nanoparticle Formulation and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Hydrogenated soya phosphatidylcholine (HSPC) and methoxypolyethyleneglycol (MW 2000)-distearylphosphati-dylethanolamine (mPEG2000-DSPE) were purchased from Lipoid (Ludwigshafen, Germany), maleimide-PEG2000 distearoylphosphatidylethanolamine (Mal-PEG2000-DSPE) was purchased from Avanti Polar Lipids (Alabaster, AL, USA). 3,3′-Dioctadecyloxacarbocyanine perchlorate (DiO), 1,1′-dioctadecyl-3,3,3′,3′-tetramethylindodicarbocyanine, and 4-chlorobenzenesulfonate salt (DiD) were purchased from Thermo Fisher Scientific (Waltham, MA, USA). Ammonium sulfate, cholesterol, α-tocopherol, XTT, PMS and DXR hydrochloride were purchased from Sigma-Aldrich Co. (St Louis, MO, USA). TAT peptide analog equipped with 3G as spacer and a C for conjugation (CGGG-RK-KRRQRRRGYG) was synthesized by Peptron Inc. (Daejeon, South Korea) with purity of 98%. Commercially available Caelyx was purchased from pharmacy. All other solvents and reagents were used as chemical grade.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!