Micromass q tof ultima global gaa076lc mass spectrometers autospec ultima tof

Manufactured by Waters Corporation

The Micromass Q-Tof Ultima GLOBAL GAA076LC mass spectrometers (Autospec-Ultima-TOF) are high-performance analytical instruments used for the detection and identification of chemical compounds. These mass spectrometers utilize a quadrupole time-of-flight (Q-TOF) configuration to analyze the mass-to-charge ratios of ionized molecules. The Ultima GLOBAL model is designed to provide reliable and accurate results for a wide range of analytical applications.

Automatically generated - may contain errors

2 protocols using micromass q tof ultima global gaa076lc mass spectrometers autospec ultima tof

1

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a Jasco P-1020 digital polarimeter (Jasco, Tokyo, Japan). The UV spectra were recorded on a Beckman DU640 spectrophotometer (Beckman Ltd., Shanghai, China). The CD spectra were obtained on a Jasco J-810 spectropolarimeter (Jasco, Tokyo, Japan). The NMR spectra were measured by Agilent 500 MHz (Agilent, Beijing, China), JEOL JNMECP 600 spectrometers (JEOL, Beijing, China). The 7.26 ppm and 77.16 ppm resonances of CDCl3 were used as internal references for the 1H and 13C NMR spectra, respectively. The 7.16 ppm and 128.06 ppm resonances of C6D6 were used as internal references for the 1H and 13C NMR spectra, respectively. The HRESIMS spectra were measured on Micromass Q-Tof Ultima GLOBAL GAA076LC mass spectrometers (Autospec-Ultima-TOF, Waters, Shanghai, China). Semi-preparative HPLC was performed using a Waters 1525 pump (Waters, Singapore) equipped with a 2998 photodiode array detector and a YMC C18 column (YMC, 10 × 250 mm, 5 μm). Silica gel (200–300 mesh, 300–400 mesh, and silica gel H, Qingdao Marine Chemical Factory, Qingdao, China) was used for column chromatography.
+ Open protocol
+ Expand
2

Spectroscopic Analysis of Chemical Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured using a Jasco P-1020 digital polarimeter (Jasco, Tokyo, Japan). The UV spectra were recorded using a Beckman DU640 spectrophotometer (Beckman Ltd., Shanghai, China). The CD spectra were obtained using a Jasco J-810 spectropolarimeter (Jasco, Tokyo, Japan). The NMR spectra were measured using Agilent 500 MHz (Agilent, Beijing, China) and JEOL JNMECP 600 spectrometers (JEOL, Beijing, China). The 7.26 ppm and 77.16 ppm resonances of CDCl3 were used as internal references for the 1H and 13C NMR spectra, respectively. The HRESIMS spectra were measured using Micromass Q-Tof Ultima GLOBAL GAA076LC mass spectrometers (Autospec-Ultima-TOF, Waters, Shanghai, China). Semi-preparative HPLC was performed using a Waters 1525 pump (Waters, Singapore) equipped with a 2998 photodiode array detector and a YMC C18 column (YMC, 10 × 250 mm, 5 μm). Silica gel (200–300 mesh, 300–400 mesh, and silica gel H, Qingdao Marine Chemical Factory, Qingdao, China) was used for column chromatography.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!