The largest database of trusted experimental protocols

Drx 700 mhz spectrometer

Manufactured by Bruker

The DRX 700 MHz spectrometer is a high-resolution nuclear magnetic resonance (NMR) instrument designed for advanced analytical and structural studies. The core function of this spectrometer is to generate a strong magnetic field and detect the resonant frequency of nuclear spins within a sample, providing detailed information about the chemical composition and molecular structure of the analyzed material.

Automatically generated - may contain errors

3 protocols using drx 700 mhz spectrometer

1

NMR Analysis of Protein UreG

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were acquired at 298 K on a Bruker DRX 700 MHz spectrometer operating at the proton frequencies of 700.13 MHz (16.44 T) on uniformly 15N- enriched samples of ca. 0.5 mM UreG in 20 mM TrisHCl buffer at pH 8, containing 150 mM NaCl, 1 mM TCEP, in the absence and in the presence of 2 mM SDS. The spectrometer was equipped with a triple-resonance 5-mm TCI cryo-probe with pulse field gradients along the z-axis. The spectra were acquired using 2048 × 128 number of complex points and the hsqcfpf3gpphwg Bruker library pulse sequence.
+ Open protocol
+ Expand
2

NMR Characterization of C-Ps Standards

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR samples for C-Ps standards were prepared by dissolving C-Ps1 (SSI, CWPS), or a mixture of C-Ps1 and C-Ps2 (SSI, CWPS-Multi) in the Deuterium oxide (D2O, 99.96% atom D) containing 0.01% (v/v) dimethylsulfoxide (DMSO), used as an internal intensity standard and 0.01% (w/v) DSS-d6, used as an internal chemical-shift standard. The concentration of the C-Ps standard in the NMR sample is about 5 mg/mL. 1H NMR spectra were acquired at 49 °C on a Varian DD2 600 MHz spectrometer with a 5 mm HCN CryoProbe and by running the VnmrJ version 4.2. 1H NMR spectra were recorded using a standard one-pulse experiment with 32,768 data points, a spectral width of 10 ppm, and 4 scans. For the quantitative study, relaxation time was set to 57 s to ensure a full recovery of each signal. One-dimensional 31P NMR spectra were acquired at 25 °C on the Bruker DRX 700 MHz spectrometer with an HCP Cryoprobe. Suitable signal-to-noise 31P spectra were recorded, accumulating approximately 256 scans with 32,768 data points and a spectral width of 75 ppm, weighted with 2.0 Hz line broadening, and were Fourier transformed. The ratio of C-Ps1 and C-Ps2 in the CWPS-Multi was provided by SSI and confirmed by 31P NMR (Supplementary Figure S2). Quantitative NMR analysis for C-Ps was performed based on the resonance integration of choline signals at 3.22 ppm and the DMSO signal at 2.71 ppm (Supplementary Figure S3).
+ Open protocol
+ Expand
3

Dlx5-DNA Interaction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
1:1.1 Dlx5:DNA samples were prepared by addition of double-stranded DNA sequences to a 1 mM protein solution. The 2D [15N, 1H]-HSQC spectra used to study the Dlx5 – DNA interaction were recorded at 298K with 1024 × 256 complex data points, on a Bruker DRX 700 MHz spectrometer equipped with a 1.7-mm microcoil probehead.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!