Rapid Visco Analyzer for Starch Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pasting characteristic of the four and their blends were determined according to ICC No 162 method. Rapid visco analyzer (RVA) series 4 (RVA; series 4, Newport Scientific P.T.V., Warriewood, Australia) with the aid of thermocline for Windows (version 1.1. Software, 1996) provided by the instrument manufacturer was used for the analysis. The 12‐min profile was used for all the analyses. It consists of idle temp of 50°C for 1 min, then 50–95°C in 3 min 45 sec, held at 95°C for 2 min 30 sec, cooled to 50°C over 3 min 45 sec, final, held at 50°C for 2 min. Two paddle speeds of 960 revolutions per minute for the first 10 sec followed by 150 revolutions per minute were employed for the remaining duration of the test cycle. The weight per sample used for each analysis was calculated from the formula:
Corrected sample weight for R V A (S)=A×100100M,
(W)=25+(AS),
where = Weight of flour sample: using the R V A manual as a guide.
= Corrected sample weight.
= Actual moisture content of the sample.
= Volume of water used.
+ Open protocol
+ Expand
2

Rapid Visco Analysis of Treated Flour

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pasting characteristics of the treated flour were determined according to ICC No 162 method. Rapid visco analyser (RVA) series 4 (RVA; series 4, Newport Scientific P.T.V., Warriewood, Australia) with the aid of thermocline for Windows (version 1.1. Software, 1996) was used for the analysis. The 12‐min profile was used for all the analyses. It consists of idle temp of 50°C for 1 min, then 50–95°C in 3 min 45 sec, held at 95°C for 2 min 30 sec, cooled to 50°C over 3 min 45 sec, finally, held at 50°C for 2 min. Two paddle speeds of 960 rpm for the first 10 sec followed by 150 rpm were employed for the remaining duration of the test cycle. The weight per sample used for each analysis was calculated from the formula:
Corrected sample weight for RVA(S)=A×100100M
(W)=25+(AS)
where A = weight of flour sample: using the RVA manual as a guide.
S = corrected sample weight.
M = actual moisture content of the sample.
W = volume of water used.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!