The largest database of trusted experimental protocols

Inorganic anion test mixture

Manufactured by Agilent Technologies
Sourced in Germany

The Inorganic Anion Test Mixture is a laboratory product designed for the analysis and identification of inorganic anions. It provides a standardized mixture of common inorganic anions, allowing for the assessment and verification of analytical techniques and methods used in the detection and quantification of these species.

Automatically generated - may contain errors

2 protocols using inorganic anion test mixture

1

Inorganic Anion Mixture Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Agilent’s Inorganic Anion Test Mixture stock (1000 ppm fluoride, chloride, bromide, nitrite, nitrate, sulfate, and 2000 ppm phosphate) was diluted 1:10 with deionized (DI) water obtained from EMD Millipore Elix10 Water Purification System (Darmstadt, Germany) and used as a standard. Stocks of the following inorganic anions (from their sodium or potassium salts) and organic acids (i.e., lactic acid) were made at 1000 ppm: acetate, arsenate, azide, bicarbonate/carbonate, bromide, chloride, fluoride, lactate, nitrate, nitrite, phosphate, silicate, sulfate, and thiosulfate. Each anion and organic acid was diluted from its stock solution to make a 20 ppm standard mixture and was filtered using a 0.22 μm PES syringe filter (Argos Technologies, Elgin, IL, USA). The running buffer/BGE was Agilent’s proprietary Basic Anion Buffer (pH 12.0) obtained from their Forensic Anion Solution Kit. The BGE was degassed for 10 min in a TA Instruments degassing station (New Castle, DE, USA) using 2 mL glass CE vials from Agilent Technologies prior to runs.
+ Open protocol
+ Expand
2

Inorganic Anion Mixture Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Agilent’s Inorganic Anion Test Mixture stock (1000 ppm fluoride, chloride, bromide, nitrite, nitrate, sulfate, and 2000 ppm phosphate) was diluted 1:10 with deionized (DI) water obtained from EMD Millipore Elix10 Water Purification System (Darmstadt, Germany) and used as a standard. Stocks of the following inorganic anions (from their sodium or potassium salts) and organic acids (i.e., lactic acid) were made at 1000 ppm: acetate, arsenate, azide, bicarbonate/carbonate, bromide, chloride, fluoride, lactate, nitrate, nitrite, phosphate, silicate, sulfate, and thiosulfate. Each anion and organic acid was diluted from its stock solution to make a 20 ppm standard mixture and was filtered using a 0.22 μm PES syringe filter (Argos Technologies, Elgin, IL, USA). The running buffer/BGE was Agilent’s proprietary Basic Anion Buffer (pH 12.0) obtained from their Forensic Anion Solution Kit. The BGE was degassed for 10 min in a TA Instruments degassing station (New Castle, DE, USA) using 2 mL glass CE vials from Agilent Technologies prior to runs.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!