Fluorolog 3 model fl3 22 spectrofluorometer

Manufactured by Horiba
Sourced in United States

The Fluorolog-3 Model FL3-22 is a spectrofluorometer manufactured by Horiba. It is designed to measure the fluorescence emission spectra of samples. The instrument is capable of recording fluorescence excitation and emission spectra, as well as time-resolved fluorescence measurements.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using fluorolog 3 model fl3 22 spectrofluorometer

1

Thioflavin T Fluorescence Spectroscopy

Check if the same lab product or an alternative is used in the 5 most similar protocols
Thioflavin T (ThT) fluorescence spectra were recorded on Fluorolog-3 Model FL3-22 spectrofluorometer (Horiba Jobin Yvon, Park Avenue Edison, NJ, USA). ThT spectra of samples were recorded in 10 µM ThT solution in 10 mM phosphate buffer pH 7.4. Briefly, peptide solutions were diluted to 10 µM peptide concentrations in 10 µM ThT solution in 10 mM phosphate buffer pH 7.4. Blank ThT spectra were recorded by adding same volumes of cosolvents in 10 µM ThT solution in 10 mM phosphate buffer pH 7.4. The excitation wavelength was set at 450 nm, slit width at 2 nm, and emission slit width at 5 nm.
+ Open protocol
+ Expand
2

Fluorescence Spectroscopy of Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Steady-state fluorescence spectra for the nanoparticle suspensions were recorded on a Horiba Fluorolog-3 Model FL3-22 spectrofluorometer (double-grating excitation and double-grating emission monochromator) after excitation. Optically dilute aqueous solutions of the nanoparticles, with absorbance < 0.1 au, were prepared in 1 cm path length quartz cuvettes. Fluorescence spectra were obtained under ambient conditions (i.e., air, ~ 21% oxygen in volume). For phosphorescence measurements, vials were capped with a 12 mm PTFE/silicone/PTFE seal (Chromatography Research Supplies) and were continuously purged with analytical grade N2 (Praxair) for 5 min before measurements. For 21% O2 (i.e. air), measurements were taken under ambient conditions (open vial, no cap). Oxygen calibration was performed as previously described with Cole-Palmer flow gauges with mixtures of analytical grade O2, N2, and 1% O2 (in N2) gases (Praxair)29 (link).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!