The CT Scanning parameters were as follows: slice thickness = 1–2 mm, FOV = 350 mm × 350 mm, tube rotation = 0.6–0.9 second and detector collimation = 1 mm. The irradiation dose parameters were as follows: 120–130 kVp and 100–200 mA (according to the machine type as well as patient age and weight). Intravenous contrast administration was not utilized.
Brilliant 16
The Brilliant-16 is a laboratory equipment product manufactured by Siemens. It is a high-performance analytical instrument designed for conducting various scientific analyses and experiments. The core function of the Brilliant-16 is to provide precise and reliable data collection and processing capabilities for researchers and laboratory professionals.
2 protocols using brilliant 16
Multidetector CT Examination Parameters
The CT Scanning parameters were as follows: slice thickness = 1–2 mm, FOV = 350 mm × 350 mm, tube rotation = 0.6–0.9 second and detector collimation = 1 mm. The irradiation dose parameters were as follows: 120–130 kVp and 100–200 mA (according to the machine type as well as patient age and weight). Intravenous contrast administration was not utilized.
Detailed Multimodal CT Imaging Protocol
CT scanning parameters were as follows: slice thickness, 1–2.5 mm; FOV = 350mm × 350 mm; tube rotation, 0.6–0.9 s; detector collimation, 1 mm; helical mode (volumetric HRCT); kVp and mA per slice, 120–130 kVp and 200–400 mA, according to the type of MSCT machine used; the weight of the patient; and the clinical indication.
Intra-venous contrast administration was done to 11 patients only as clinically requested. It was non-ionic iodinated contrast (350mg/ml concentration and 70–90 ml volume at 4–5 ml/s injection rate). No major reactions were reported. Only minor reactions were reported such as sense of hotness and nausea, which needed noting but assurance.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!