Electrophysiological recordings (EMG studies) were performed in all groups at the end of the study. EMG was obtained three times from the right sciatic nerve stimulated supramaximally (intensity 10 V, duration 0.05 ms, frequency 1 Hz, in the range of 0.5-5000 Hz, 40 kHz/s with a sampling rate) by a bipolar subcutaneous needle stimulation electrode (BIOPAC Systems, Inc, Santa Barbara, CA) from the sciatic notch. CMAPs were recorded from 2-3 interosseous muscles by unipolar platinum electrodes. Data were evaluated using Biopac Student Lab Pro version 3.6.7 software (BIOPAC Systems, Inc) with distal latency and amplitude of CMAP as the parameters. During the EMG recordings, rectal temperatures of the rats were monitored by a rectal probe (HP Viridia 24-C; Hewlett-Packard Company, Palo Alto, CA) and the temperature of each rat was kept at approximately 36 -37 °C by heating pad. All experiments were performed between 10:00 a.m. and 14:00 p.m.
Hp viridia 24 c
The HP Viridia 24-C is a high-performance liquid chromatography (HPLC) system designed for laboratory use. It features a 24-channel configuration, allowing for parallel analysis of multiple samples. The system is capable of delivering precise and reproducible results, making it suitable for a variety of analytical applications.
5 protocols using hp viridia 24 c
Electrophysiological Assessment of Rat Sciatic Nerve
Electrophysiological recordings (EMG studies) were performed in all groups at the end of the study. EMG was obtained three times from the right sciatic nerve stimulated supramaximally (intensity 10 V, duration 0.05 ms, frequency 1 Hz, in the range of 0.5-5000 Hz, 40 kHz/s with a sampling rate) by a bipolar subcutaneous needle stimulation electrode (BIOPAC Systems, Inc, Santa Barbara, CA) from the sciatic notch. CMAPs were recorded from 2-3 interosseous muscles by unipolar platinum electrodes. Data were evaluated using Biopac Student Lab Pro version 3.6.7 software (BIOPAC Systems, Inc) with distal latency and amplitude of CMAP as the parameters. During the EMG recordings, rectal temperatures of the rats were monitored by a rectal probe (HP Viridia 24-C; Hewlett-Packard Company, Palo Alto, CA) and the temperature of each rat was kept at approximately 36 -37 °C by heating pad. All experiments were performed between 10:00 a.m. and 14:00 p.m.
Electrophysiological Assessment of Cisplatin-Induced Neuropathy
Cisplatin-Induced Nerve Damage Assessment
Cisplatin-Induced Sciatic Nerve EMG Assessment
Electrophysiological Evaluation of Sciatic Nerve in Rats
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!