The largest database of trusted experimental protocols

80 protocols using iron 3 acetylacetonate

1

Synthesis of Multifunctional Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals and materials used were commercially available and applied without further purification. Iron (III) acetylacetonate (98%), oleic acid (90%), dibenzyl ether were purchased from Sigma-Aldrich Co. (St. Louis, MO, USA). Platinum (II) acetylacetonate (97%), oleylamine (80–90%), oleyl alcohol, diphenyl ether, N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride, N-hydroxysuccinimide, N, N’-dicyclohexylcarbodiimide, dopamine hydrochloride, 2-(N-morpholino) ethanesulfonic acid (MES) buffer and rhodamine B isothiocyanate (RITC) were purchased from Aladdin Industrial Inc. (Shanghai, China). Ethanol, hexane, diethyl ether, chloroform, dimethylformamide and sodium carbonate were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). α,ω-dicarboxyl poly(ethylene glycol) (molecular weight = 2000) was acquired from Ponsure Biological Co. (Shanghai, China). Cyclic arginyl–glycyl-aspartic acid (RGD) peptide (cRGDyK) was obtained from GL Biochem (Shanghai) Ltd. Foetal bovine serum (FBS) was purchased from Sijiqing Biologic Co., Ltd. (Hangzhou, China). Dulbecco’s modified eagle medium (DMEM) and trypsin-EDTA solution (0.5% trypsin, 5.3 mM EDTA tetrasodium) were purchased from Jinuo Biomedical Technology Co., Ltd. (Hangzhou, China). Distilled water was prepared by Milli-Q (Millipore, USA).
+ Open protocol
+ Expand
2

TEOS-Fe Nanoparticle Synthesis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Tetraethyl orthosilicate (TEOS 99.999%, Sigma Aldrich) and iron (III) acetylacetonate (99.9% trace metals grade, Sigma Aldrich) were utilized as Si and Fe precursors. Toluene (99.99%, Sigma Aldrich) was used as a solvent for these chemicals within the atomizer. Teflon filters collected the excess particles that were characterized using offline analysis.
+ Open protocol
+ Expand
3

Synthesis of Cobalt-Doped Superparamagnetic Iron Oxide Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
To enhance the magnetic properties of the SPION-loaded micelles, cobalt-doped superparamagnetic iron oxide nanoparticles (SPIONs) were synthesized, as previously described.58 (link) The 10 nm cobalt-doped SPIONs could be readily synthesized in one step (i.e., vs. sequential seed growth) and efficiently loaded into the micelles. Briefly, 1 mmol cobalt chloride (Alfa Aesar), 2 mmol iron (III) acetylacetonate (Sigma), 2 mmol oleic acid (Chem-Impex International), 6 mmol oleylamine (Sigma), and 5 mmol 1, 2-hexadecanediol (Sigma) were reacted in 20 mL benzyl ether (Sigma) in a two-neck flask while stirred under nitrogen. The reaction was heated to 200°C for 30 minutes, followed by heating to reflux for 75 minutes. The product was cooled to room temperature and washed with 100% ethanol by centrifugation at 5,500 g × 15 minutes. The pellet was resuspended in toluene and large aggregates were removed by centrifugation at 3,000 g × 15 minutes.
+ Open protocol
+ Expand
4

Functionalized Nanoparticles for Targeted Drug Delivery

Check if the same lab product or an alternative is used in the 5 most similar protocols
Iron (III) acetylacetonate (97%), Dibenzyl ether (>98%) and Dopamine hydrochloride (DA) were purchased from Sigma. Zinc acetylacetonate hydrate (97%), morpholineethanesulfonic acid (MES), 1-(3-dimethylaminopropyl)-3-ethyl carbodiimide hydrochloride (EDC, > 98.0%), N-hydroxy succinimide (NHS, 98%) and N,N-Dimethylformamide (DMF) were purchased from Aladdin. Phosphate buffer saline (PBS), Dulbecco's Modified Eagle's medium (DMEM), penicillin/streptomycin and fetal bovine serum (FBS) were purchased from Hyclone. mPEG-NH2 (MW=2000) was purchased from SINOPEG Biotech Co. Ltd (Xiamen China). Poly (acrylic acid) (PAA) (MW=2000) was purchased from Macklin Shanghai China. Epidermal Growth Factor (EGF) peptide was purchased from GL Biochem Ltd. (Shanghai). The CCK-8 kit and Propidium Iodide (PI) stain were purchased from Beijing Zoman Biotechnology Co., Ltd. Calcein, Fluo-4 AM and LDH cytotoxicity Assay Kit were purchased from Thermo Fisher Scientific, Shanghai, China. Ultra-pure water was used throughout all experiments. Matrigel was purchased from Corning, USA.
+ Open protocol
+ Expand
5

Synthesis and Characterization of Metal Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Copper (II) acetylacetonate (Cu(acac)2, 97%), iron (III) acetylacetonate (Fe(acac)3, ≥99.9%), 1-dodecanethiol (DDT, ≥ 98%), oleic acid (OA, technical grade, 90%), oleylamine (Olam, technical grade, 70%), toluene (anhydrous), nitric acid (70%, TraceMetal grade), and tetrachloroethylene (TCE, ≥ 99.9%) were purchased from Sigma-Aldrich. Hexanes (Optima for HPLC, ≥ 99.9%), isopropyl alcohol (99.5%), ethanol (anhydrous, histological), and cobaltocene (98%) were purchased from Fisher Scientific, while sulfur (refined, 99.5%) was procured from ACROS Organics. Quartz glass cuvettes were sourced from Starna Cells Inc. Gold nanorods (10 nm × 67 nm), citrate-coated, were purchased from Nanopartz, and 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[methoxy-(polyethylene glycol)-2000] (ammonium salt) was purchased from Avanti Lipids. All air-sensitive materials were stored and handled in a glovebox under an argon atmosphere.
+ Open protocol
+ Expand
6

Synthesis of Functionalized Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Iron (III) acetylacetonate (99%), oleic acid (technical grade 90%), benzyl ether (98%), and BSA (98%) were purchased from Sigma-Aldrich (St. Louis, MO, USA) and used as received; 4-biphenylcarboxylic acid (99%, Acros Organics, Belgium, WI, USA), acetone (99.5%), hexanes (98.5%), sodium bicarbonate (99.7%), nitric acid (70%), and hydrogen peroxide (30%) were purchased from Fisher Scientific (Waltham, MA, USA). The BSA Cy5.5 conjugate (BSA Cy5.5, 10 mg·mL‒1 in saline) was purchased from Protein Mods (Burlington, ON, Canada).
+ Open protocol
+ Expand
7

Synthesis of Magnetic Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Iron (III) acetylacetonate (97%), 1,2-hexadecanediol (90%), benzyl ether (98%), oleic acid (OA, 70%) and oleylamine (OAm, 70%) were purchased from Sigma-Aldrich Corporation. Diethylenetriaminepentaacetic dianhydride (98%) was purchased from TCI Chemical Industry Development Corporation. NH2-PEG-dopamine (Mw 1 k and 2 k) were purchased from Shanghai Ponsure Biotech, Inc. (Shanghai, China). Gadolinium (III) chloride (GdCl3) and ethylenediaminetetraacetic acid disodium salt (EDTA2Na) were purchased from Aladdin Industrial Corporation. All other chemicals and solvents were of analytical grade and used without further purification.
+ Open protocol
+ Expand
8

Synthesis of Graphene-Based Nanomaterials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ammonium molybdate tetrahydrate, thiourea, ethanol, cobalt(iii) acetylacetonate, iron(iii) acetylacetonate, oleylamine, and pure graphite powder (99.99%) were purchased from Sigma Aldrich. HNO3, H2SO4, and KClO3 were procured from Fisher Scientific. All chemicals were reagent grade and were used as received without further purification. High purity deionized (DI) water was used in this work as a solvent and for purification.
+ Open protocol
+ Expand
9

Synthesis of Monodisperse Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
In this study was used: iron (III) acetylacetonate (99%) from Sigma Aldrich (St. Louis, MO, USA), oleic acid (90%) from Panreac (Barcelona, Spain), benzyl ether (99%) from Sigma Aldrich (Madrid, Spain), 4-biphenylcarboxylic acid (99%) from Sigma Aldrich (Madrid, Spain), toluene (99.8%) from Panreac (Barcelona, Spain), hexane (99%) from Panreac (Barcelona, Spain), chloroform (99.9%) from Panreac (Barcelona, Spain), and nitrogen (99%) from Air Liquide (Paris, France). All solutions were made with distilled water.
+ Open protocol
+ Expand
10

Synthesis of Magnetic Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lithium carbonate, iron(iii)-acetylacetonate, oleylamine (technical grade, 70%), oleic acid (technical grade, 90%), phosphoric acid 85 wt% in H2O (H3PO4) and tetraethyleneglycol (TEG) were purchased from Sigma-Aldrich and used without purification. Acetone and hexane were purchased from Samchun Chemical (Korea) and used as received.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.