Fgf 21 quantikine elisa kit

Manufactured by R&D Systems
Sourced in United States

The FGF-21 Quantikine ELISA kit is a quantitative sandwich enzyme immunoassay designed to measure human Fibroblast Growth Factor 21 (FGF-21) levels in cell culture supernates, serum, and plasma. The assay employs an antibody specific for FGF-21 coated on a microplate. Standards and samples are pipetted into the wells, and any FGF-21 present is bound by the immobilized antibody.

Automatically generated - may contain errors

10 protocols using fgf 21 quantikine elisa kit

1

Quantifying FGF Levels in Mice and Humans

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma levels of FGF21 and FGF15 were measured in mice by the FGF-21 Quantikine ELISA kit (MF2100; R&D Systems, Minneapolis, MN, USA) and mouse FGF15 ELISA kit (RD-FGF15-Mu; Reddot Biotech, Kelowna, BC, Canada), respectively. For human plasma samples, the FGF-21 Quantikine ELISA kit (DF2100; R&D Systems) and FGF-19 Quantikine ELISA kit (DF1900; R&D Systems) were used. The experiments were carried out in duplicates, and average values were used for analysis.
+ Open protocol
+ Expand
2

Plasma FGF21 Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Whole blood was collected in a lithium heparin tube (BD, Franklin Lakes, NJ, USA), and centrifuged at 2000 r.p.m. for 20 min. Then, plasma was collected for FGF21 assay using a FGF21 Quantikine Elisa kit (R&D systems, Minneapolis, MN, USA) according to the manufacturer’s instructions.
+ Open protocol
+ Expand
3

Quantification of FGF21 in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Levels of FGF21 were determined in plasma sampled before intracardiac perfusion in non-fasted mice and in BAT protein extracts using the mouse/rat FGF21 Quantikine ELISA kit (MF2100, R&D systems, Minneapolis, MN).
+ Open protocol
+ Expand
4

Plasma Biomarker Profiling in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected from mice under anesthesia. Plasma was obtained after centrifugation (15 min, 845 ×g, 4°C) and concentrations of urea nitrogen, creatinine, cystatin C, glucose, total cholesterol, triglycerides, free fatty acids, phospholipids, FGF21 were measured using the BUN-Test-Wako (Wako, 279–36201), the CRE-EN Kainos (Kainos, TKA7500), cystatin C (mouse) ELISA kit (BioVendor, RD291009200R), the Glucose CII-test (Wako, 439–90901), the Cholesterol E-test (Wako, 439–17501), the Triglyceride E-test (Wako, 432–40201), the NEFA C-test (Wako, 279–75401), the Phospholipid C-test (Wako, 433–36201), and the Mouse/Rat FGF21 Quantikine ELISA Kit (R&D Systems, MF2100). Urinary albumin excretion was measured with the MicrofluoralTM microalbumin test (Progen, PR2005). All kits were used in accordance with the manufacturer’s protocols.
+ Open protocol
+ Expand
5

Plasma Biomarker Profiling in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected from mice under anesthesia. Plasma was obtained after centrifugation (15 min, 845 ×g, 4°C) and concentrations of urea nitrogen, creatinine, cystatin C, glucose, total cholesterol, triglycerides, free fatty acids, phospholipids, FGF21 were measured using the BUN-Test-Wako (Wako, 279–36201), the CRE-EN Kainos (Kainos, TKA7500), cystatin C (mouse) ELISA kit (BioVendor, RD291009200R), the Glucose CII-test (Wako, 439–90901), the Cholesterol E-test (Wako, 439–17501), the Triglyceride E-test (Wako, 432–40201), the NEFA C-test (Wako, 279–75401), the Phospholipid C-test (Wako, 433–36201), and the Mouse/Rat FGF21 Quantikine ELISA Kit (R&D Systems, MF2100). Urinary albumin excretion was measured with the MicrofluoralTM microalbumin test (Progen, PR2005). All kits were used in accordance with the manufacturer’s protocols.
+ Open protocol
+ Expand
6

Blood Biomarker Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood tests were performed on all subjects after 12 hr of fasting. The blood was drawn at the same time under the same conditions before and after the exercise. A disposable needle was used to draw 5 mL of venous blood from the anterior cardinal vein. The blood was stored in serum separating tubes for serum and centrifuged for 10 min at 3,000 rpm; 200 μL of the serum was stored in a sample tube. The irisin and FGF-21 levels were assessed using the enzyme linked immunosorbent assay (ELISA) method with the irisin ELISA kit (BioVendor, Brno, Czech Republic) and FGF-21 Quantikine ELISA kit (R&D System, Minneapolis, MN, USA), respectively.
+ Open protocol
+ Expand
7

FGF21 Quantification from Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Whole blood was collected in a lithium heparin tube (BD, Franklin Lakes, NJ, USA), and centrifuged at 2000 rpm for 20 min at 4 °C. Later, 70 μL of plasma from FGF21-null and WT groups were collected for FGF21 assay using a FGF21 Quantikine Elisa kit (R&D systems, Minneapolis, MN, USA) according to the manufacturer’s instructions.
+ Open protocol
+ Expand
8

Serum FGF21 Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood was collected from the tail vein and centrifuged at 5,000 g for 10 min at 4 °C. Serum Fgf21 levels were determined by a FGF-21 Quantikine ELISA kit (R&D Systems).
+ Open protocol
+ Expand
9

Biomarker Quantification in Metabolic Studies

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum insulin levels were measured with insulin ELISA kit (Crystal Chem, Downers Grove, IL, USA). Plasma triglyceride and cholesterol concentrations were measured by using triglyceride assay kit (Cayman Chemicals, Ann Arbor, MI). Plasma FGF21 was determined with an FGF21 Quantikine Elisa kit (R&D Systems, Minneapolis, MN, USA).
+ Open protocol
+ Expand
10

Quantifying Metabolic Biomarkers in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma FGF21 concentrations were measured by ELISA (FGF21 Quantikine ELISA kit; R&D Systems, Minneapolis, MN, USA). Plasma ketone bodies were measured by enzymatic cycling method (3-HB-L test kit and TKB-L test kit; Kainos, Tokyo, Japan). Plasma glucagon concentrations were measured by ELISA (Glucagon ELISA kit; Mercodia, Uppsala, Sweden).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!