The largest database of trusted experimental protocols

2k x 2k eagle ccd camera

Manufactured by Thermo Fisher Scientific

The 2k x 2k Eagle CCD camera is a high-resolution digital imaging device designed for scientific and research applications. It features a 2048 x 2048 pixel sensor and is capable of capturing detailed images.

Automatically generated - may contain errors

3 protocols using 2k x 2k eagle ccd camera

1

Cryo-EM Structural Analysis of Proteins

Check if the same lab product or an alternative is used in the 5 most similar protocols
Proteins were diluted to approximately 0.02 mg/mL with buffer containing 10 mM HEPES, pH 7.0 and 150 mM NaCl, adsorbed to a freshly glow-discharged carbon-coated copper grid, washed with the same buffer, and stained with 0.7% uranyl formate. Datasets were collected using SerialEM (69 (link)) on an FEI Tecnai T20 microscope equipped with a 2k x 2k Eagle CCD camera and operated at 200 kV. The nominal magnification was 100,000, corresponding to a pixel size was 0.22 nm. Particles were selected from micrographs automatically using in-house written software (YT, unpublished), followed by manual correction using EMAN2 (70 (link)), when necessary. Reference-free 2D classifications were performed with Relion 1.4 (71 (link)).
+ Open protocol
+ Expand
2

Cryo-EM Specimen Preparation and Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples were diluted with a buffer containing 20 mM HEPES, pH 7.0, 150 mM NaCl, adsorbed to a freshly glow-discharged carbon-film grid, washed with the above buffer, and stained with 0.7% uranyl formate. Images were collected semi-automatically at a magnification of 100,000 using SerialEM61 on a FEI Tecnai T20 microscope equipped with a 2k x 2k Eagle CCD camera and operated at 200 kV. The pixel size was 0.22 nm/px. Particles were picked manually using the swarm mode in e2boxer from the EMAN2 software package62 . Reference-free 2D classification was performed using EMAN2 and SPIDER63 .
+ Open protocol
+ Expand
3

Cryo-EM Specimen Preparation and Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples were diluted with a buffer containing 20 mM HEPES, pH 7.0, 150 mM NaCl, adsorbed to a freshly glow-discharged carbon-film grid, washed with the above buffer, and stained with 0.7% uranyl formate. Images were collected semi-automatically at a magnification of 100,000 using SerialEM61 on a FEI Tecnai T20 microscope equipped with a 2k x 2k Eagle CCD camera and operated at 200 kV. The pixel size was 0.22 nm/px. Particles were picked manually using the swarm mode in e2boxer from the EMAN2 software package62 . Reference-free 2D classification was performed using EMAN2 and SPIDER63 .
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!