The largest database of trusted experimental protocols

Moticam2000

Manufactured by Shimadzu
Sourced in Japan

The MOTICAM2000 is a digital microscope camera that captures high-quality images and videos. It features a CMOS sensor, USB 2.0 connectivity, and supports resolutions up to 2048 x 1536 pixels. The camera is designed for use with a wide range of microscopes.

Automatically generated - may contain errors

3 protocols using moticam2000

1

Characterization of PNIPAAm Polymer

Check if the same lab product or an alternative is used in the 5 most similar protocols
The number-averaged molecular weight (Mn) and polydispersity index (Mw/Mn) of PNIPAAms were determined by size-exclusion chromatography (SEC) with poly(methyl methacrylate) calibration (standard samples were purchased from Agilent, Santa Clara, California, USA). DMF containing 10 mM LiBr was used as an eluent, and the measurement was conducted at 40 °C using three polystyrene gel columns (PLgel 5 μm MIXED-C, PLgel 3 μm MIXED-E and Shodex KF-805L) connected to a Shimadzu LC-10AD precision pump, a Shimadzu RID-10A refractive index detector, and a Shimadzu SPD-10A UV–VIS detector set at 250 nm (Shimadzu, Kyoto, Japan). 1H NMR analysis was performed with a JEOL JNM-LA400 spectrometer (JEOL, Akishima, Japan), operating at 399.65 MHz. The swelling degree of PNIPAAm gels in water was determined from the diameter of cylindrical gels using a digital microscope (MOTICAM2000, Shimadzu, Kyoto, Japan). The swelling degree was calculated by (d/d0)3; d0 is the inner diameter of the capillary and d is the equilibrium diameter at predetermined temperature.
+ Open protocol
+ Expand
2

Polymer Characterization by SEC and NMR

Check if the same lab product or an alternative is used in the 5 most similar protocols
Number-average molecular weight (Mn) and polydispersity index (Mw/Mn) of polymers were determined by size-exclusion chromatography (SEC) in DMF containing 10 mM LiBr at 40 °C using three polystyrene gel columns (PLgel 5 μm MIXED-C, PLgel 3 μm MIXED-E and Shodex KF-805L) that were connected to a Shimadzu LC-10AD precision pump (Kyoto, Japan) and a Shimadzu RID-10A refractive index detector (Kyoto, Japan). The columns were calibrated against standard poly(methyl methacrylate) samples (Agilent, Santa Clara, California, USA). 1H NMR spectra were recorded on a JEOL JNM-LA400 spectrometer (Akishima, Japan), operating at 399.65 MHz. The degree of swelling was determined by measurement of the diameter of the cylindrical gels. The gels were immersed in water at predetermined temperatures, and the equilibrium diameter at given temperature, d, was measured using a digital microscope (MOTICAM2000, Shimadzu, Kyoto, Japan). The degree of swelling was calculated by (d/d0)3; d0 is the inner diameter of the capillary used for the gel preparation. The shrinking rate was evaluated by temperature-jump experiment. The cylindrical gels were immersed in water at 5 °C until the gels reached to the equilibrium swollen state. Then, the gels were quickly transferred into the hot water at 50 °C, and the change of the diameter of the gel was observed.
+ Open protocol
+ Expand
3

Optical Microscopy of Diluted Emulsions

Check if the same lab product or an alternative is used in the 5 most similar protocols
A drop of the diluted emulsion was placed on a microscope slide and viewed using an optical microscope (Motic BA200, Shimadzu, Kyoto, Japan) fitted with a digital system (Moticam 2000, Shimadzu).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!