The largest database of trusted experimental protocols

Drx 600 avance spectrometer

Manufactured by Bruker
Sourced in Germany, United States

The DRX-600 AVANCE spectrometer is a nuclear magnetic resonance (NMR) instrument manufactured by Bruker. It is designed to perform high-resolution NMR analysis of chemical samples. The core function of the DRX-600 AVANCE is to generate and detect radiofrequency signals to study the magnetic properties of atomic nuclei within a sample, providing information about the chemical structure and composition of the material.

Automatically generated - may contain errors

6 protocols using drx 600 avance spectrometer

1

NMR Analysis of Lyophilized Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
All samples for the NMR analysis were prepared, loading 500 μL of the D2O at the lyophilized product (100 mg). 1H-NMR spectra were acquired at 298 K on a Bruker DRX-600 AVANCE spectrometer, equipped with an xyz gradient unit and operating at 600.13 MHz. The data was processed with Bruker XWINNMR Software, version 2 on Silicon Graphics equipped with RISC R5000 processor, working under the IRIX 6.3 operating system.
+ Open protocol
+ Expand
2

NMR Spectroscopy Protocol for Sample Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Spectra were recorded on a Bruker DRX-600 AVANCE spectrometer (Bruker, Rheinstetten, Germany) at 600.13 MHz (1H). The 1H NMR spectra were measured at 298.2 K with acquisition of 32 k data points. After zero filling to 64 k data points, spectra were performed with a range of 7200 Hz. 32 1H NMR spectra were recorded in one measurement, using a 5 mm high precision NMR sample tube (Promochem, Wesel, Germany). For evaluation of the spectra ACD/NMR Processor Academic Edition 12.0 (Advanced Chemistry Development Inc., Toronto, Canada) was used.
+ Open protocol
+ Expand
3

NMR Characterization of Dried Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR experiments were performed using a Bruker DRX-600 Avance spectrometer operating at 600.13 MHz for 1H, equipped with an xyz gradient unit. Spectra were processed using Bruker TopSpin software (version 3.6.1, Bruker, Bremen, Germany). The dried extract was freeze dried to remove the eventual humidity, and then reconstituted in deuterated methanol (MeOD-d4) for NMR analysis.
+ Open protocol
+ Expand
4

NMR study of ALW peptide binding to IgGs

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR was performed as described previously (Janda et al., 2012 (link)). In brief, the isotope labeled ALW peptide was dissolved in NMR buffer (10 mM MES, 90 mM NaCl, pH 6.0). ALW (36 to 100 μM) and each of the IgGs (18 to 50 μM) were mixed at molar ratios of 2:1 just before the NMR experiments at 25°C. 15N-1HN heteronuclear single quantum coherence spectra (HSQC) were recorded every 2 hours on a DRX600 Avance spectrometer (Bruker Corporation) at 600 MHz. The running time was 20–22 hours in total. Data processing and analysis used nmrPipe and NMRViewJ. Triple resonance experiments were also recorded to assign the backbone resonances of ALW peptide but the resonances could not be assigned unambiguously, possibly due to proline isomerization.
+ Open protocol
+ Expand
5

Analytical Techniques for Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points were determined in open capillaries in a Gallenkamp apparatus, and are uncorrected. Merck silica gel 60 (230–400 mesh) was used for column chromatography. Merck TLC plates, silica gel 60 F254, were used for TLC. Bruker (Karlsruhe, Germany) AC200, a Varian Mercury-300 (Palo Alto, CA, USA), a Bruker DRX-400 AVANCE, or a Bruker DRX-600 AVANCE spectrometer in the indicated solvents (TMS as internal standard) were used to record the NMR spectra. In NMR spectra, the coupling constants (J) in Hz and the values of the chemical shifts are expressed in ppm. Mass spectrometry experiments were performed using an Agilent (Santa Clara, CA, USA) 1100 LC/MSD operating with an electrospray source.
+ Open protocol
+ Expand
6

NMR Characterization of Methanol Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mono and bidimensional NMR experiments were performed with a Bruker DRX-600 Avance spectrometer operating at 600.13 MHz for 1 H, equipped with an xyz gradient unit. All experiments were performed at 298 K in the methanol (CH 3 OD) solution. All the spectra were processed using the Bruker Software XWINNMR.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!