The largest database of trusted experimental protocols

Ltq orbitrap elite hybrid mass spectrometer

Manufactured by Thermo Fisher Scientific

The LTQ Orbitrap Elite Hybrid Mass Spectrometer is a high-performance mass spectrometry system that combines a linear ion trap (LTQ) with an Orbitrap mass analyzer. It provides high-resolution, accurate mass measurement capabilities for a wide range of analytical applications.

Automatically generated - may contain errors

2 protocols using ltq orbitrap elite hybrid mass spectrometer

1

Liquid Chromatography-Mass Spectrometry Analysis of Peptides

Check if the same lab product or an alternative is used in the 5 most similar protocols
The peptides were analyzed by an online LC-MS system. They were separated by reversed-phase liquid chromatography (LC), and the LC is coupled to an LTQ Orbitrap Elite Hybrid Mass Spectrometer (Thermo Scientific). MS/MS analysis was performed with a data-dependent Top20 method. The detailed information is in Supporting Information.
Raw MS files were analyzed by MaxQuant (version1.6.2.3).28 (link) MS spectra were searched against the human proteome database downloaded from UniProt using the integrated Andromeda search engine.29 All default parameters were left unchanged, except adding variable modification for glycosylation site identification (+2.9883 Da) and 3 maximum missed cleavages. Label-free quantification was also enabled with the LFQ min ratio count of 1, the match-between-runs option was enabled, and the iBAQ option was enabled. The false discovery rates (FDRs) were kept at 0.01 at the peptide spectrum match, protein, and site decoy fraction levels.
+ Open protocol
+ Expand
2

Peptide Purification and LC-MS/MS Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Eluted peptides were purified, and dried peptides were subsequently dissolved in a solution with 5% ACN and 4% formic acid (FA) prior to LC-MS/MS analysis. Peptides were separated by a Dionex UltiMate 3000 UHPLC system (Thermo Scientific), which is coupled to an LTQ Orbitrap Elite Hybrid Mass Spectrometer (Thermo Scientific) with Xcalibur software (version 3.0.63). A total of ~1 µg of peptides was loaded onto a C18-packed microcapillary column (Magic C18AQ, 3 μm, 200 Å, 100 μm × 16 cm, Michrom Bioresources) by a Dionex WPS-3000TPL RS autosampler (Thermostatted Pulled Loop Rapid Separation Nano/Capillary Autosampler). Peptides were separated by reversed-phase chromatography using an UltiMate 3000 binary pump with a 90-minute gradient of 4–30% ACN containing 0.125% FA. MS/MS analysis was performed with a data-dependent Top20 method. For each cycle, a full MS scan (resolution: 60,000) in the Orbitrap with 1 million automatic gain control (AGC) target was followed by up to 20 MS/MS in the LTQ for the most intense ions.55 (link), 56 (link) Selected ions were excluded from further sequencing for 90 seconds. Ions with single or unassigned charge were not sequenced. Maximum ion accumulation times were 1,000 ms for each full MS scan and 50 ms for MS/MS scans.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!