Aquilion cxl cx 128

Manufactured by Toshiba
Sourced in United States

The Aquilion CXL/CX 128 is a computed tomography (CT) scanner manufactured by Toshiba. It is designed to capture high-quality images of the body's internal structures. The system utilizes 128-slice technology to provide rapid, detailed scans. Its core function is to generate cross-sectional images for diagnostic purposes.

Automatically generated - may contain errors

4 protocols using aquilion cxl cx 128

1

Multidetector CT Examination Parameters

Check if the same lab product or an alternative is used in the 5 most similar protocols
Multiple multi-detector CT machines had performed the MSCT examinations including Philips Brilliant-16 (USA), Siemens SOMATOM Emotion 16 and Siemens SOMATOM Sensation 64 (Germany), Canon Medical Systems; Toshiba Aquilion 64 and Toshiba Aquilion CXL/CX 128 (USA).
The CT Scanning parameters were as follows: slice thickness = 1–2 mm, FOV = 350 mm × 350 mm, tube rotation = 0.6–0.9 second and detector collimation = 1 mm. The irradiation dose parameters were as follows: 120–130 kVp and 100–200 mA (according to the machine type as well as patient age and weight). Intravenous contrast administration was not utilized.
+ Open protocol
+ Expand
2

Detailed Multimodal CT Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
CT examinations were conducted using multiple MDCT machines including: GE LightSpeed Plus 4 slice CT scanner (USA), Philips Brilliant-16 (USA), Siemens SOMATOM Emotion 16 and Siemens SOMATOM Sensation 64 (Germany), Canon Medical Systems; Toshiba Aquilion 64 and Toshiba Aquilion CXL/CX 128 (USA).
CT scanning parameters were as follows: slice thickness, 1–2.5 mm; FOV = 350mm × 350 mm; tube rotation, 0.6–0.9 s; detector collimation, 1 mm; helical mode (volumetric HRCT); kVp and mA per slice, 120–130 kVp and 200–400 mA, according to the type of MSCT machine used; the weight of the patient; and the clinical indication.
Intra-venous contrast administration was done to 11 patients only as clinically requested. It was non-ionic iodinated contrast (350mg/ml concentration and 70–90 ml volume at 4–5 ml/s injection rate). No major reactions were reported. Only minor reactions were reported such as sense of hotness and nausea, which needed noting but assurance.
+ Open protocol
+ Expand
3

Multidetector CT Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Multiple MDCT machines were used: (1) SOMATOM Sensation 64, Siemens Medical Systems, Germany, (2) Canon Medical Systems; Toshiba Aquilion 64, USA, and (3) Canon Medical Systems; Toshiba Aquilion CXL/CX 128, USA.
CT scanning parameters were slice thickness: 1–1.25 mm, tube rotation: 0.6–0.9 s, detector collimation 1 mm, 120–130 kVp, and 200 mA, FOV = 350 mm × 350 mm. Intravenous contrast administration was not used.
+ Open protocol
+ Expand
4

MDCT Imaging Parameters for Volumetric HRCT

Check if the same lab product or an alternative is used in the 5 most similar protocols
Two MDCT machines were used: Siemens SOMATOM Sensation 64 (Germany) and Toshiba Aquilion CXL/CX 128 (USA). The following CT scanning parameters were used: 1 mm slice thickness, 1 mm detector collimation, 0.6-0.9 s tube rotation, helical mode volumetric HRCT with 100-120 kVp and 80-200 mA, according to the weight of patients and clinical indication. Intra-venous contrast administration was not used.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!