Lactose standard 5

Manufactured by Merck Group
Sourced in France

Lactose standard 5 is a laboratory reference material used to calibrate and verify the performance of analytical instruments that measure lactose concentration. It is a pure, certified substance with a known lactose content.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using lactose standard 5

1

Residual Moisture Content Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
Residual moisture content in single matrix post-desiccation was determined with a Karl Fischer moisture analyser equipped with coulometer (Metrohm), and Hydranal-Coulomat titration solution (Honeywell, Fluka) in accordance with the manufacturers’ recommendations. A standard was used to calibrate the instrument performance (lactose standard 5%, MerckMillipore). Residual moisture content was expressed as a percentage (calculated from the measured mass of water as a proportion of the calculated mass of solutes in the loaded sample).
+ Open protocol
+ Expand
2

Coulometric Karl Fischer Titration of Peptides

Check if the same lab product or an alternative is used in the 5 most similar protocols
KF titration was performed using a Titrando 851 titrator instrument (Metrohm, Herisau, Switzerland), coupled to a Metrohm 874 oven sample processor and operated by the Tiamo (version 2.3) software. The C3+ peptide samples (between 2 and 6 mg) were placed in the oven and the released water was transferred to the titrator cell via a stream of dried, high purity nitrogen carrier gas. The coulometric determinations were carried out with the KF titration reagents HYDRANAL™ Coulomat CG-K and Coulomat AG-Oven (VWR, Fontenay-sous-Bois, France). Water content was calculated after correction of water determined in blank samples. A lactose standard 5% (Merck, France) was used as a control sample and the SI traceability of the results was established through calibration with NIST SRM 2890 standard (NIST, MD, USA).
+ Open protocol
+ Expand
3

Residual Moisture Content Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
Residual moisture content in single matrix post-desiccation was determined with a Karl Fischer moisture analyser equipped with coulometer (Metrohm), and Hydranal-Coulomat titration solution (Honeywell, Fluka) in accordance with the manufacturers' recommendations. A standard was used to calibrate the instrument performance (lactose standard 5%, MerckMillipore). Residual moisture content was expressed as the mass extracted per 50 µL of formulation loaded into each matrix.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!