The largest database of trusted experimental protocols

Rapid visco analyser rva 4

Manufactured by Newport Scientific
Sourced in Australia

The Rapid Visco Analyser (RVA-4) is a laboratory instrument used for the analysis of the rheological properties of various materials, including food, agricultural, and industrial products. It measures the viscosity of samples as they are subjected to a controlled temperature and shear profile.

Automatically generated - may contain errors

Lab products found in correlation

5 protocols using rapid visco analyser rva 4

1

Pasting Properties of Instant Porridges

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pasting properties of the instant porridges were determined using a Rapid Visco Analyser (RVA‐4, Newport Scientific). The pasting temperature (PT), peak viscosity (PV, the maximum hot paste viscosity), holding strength or trough viscosity (the trough at the minimum hot paste viscosity), final viscosity, breakdown (BD, peak viscosity‐holding strength or trough viscosity), and setback (SB, final viscosity‐holding strength) were obtained with Thermocline for Windows software. The viscosities were presented in centipoise (cP).
+ Open protocol
+ Expand
2

Rapid Visco Analyser Flour Pasting

Check if the same lab product or an alternative is used in the 5 most similar protocols
The flour pasting profile was measured with a Rapid Visco Analyser (RVA-4, Newport Scientific, Australia) (Additional file 1).
+ Open protocol
+ Expand
3

Analyzing Lily Starch Pasting Properties

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pasting properties of lily starch were determined by a Rapid Visco Analyser (RVA-4; Newport Scientific Pt. Ltd., Warriewood, Australia) according to Ziegler [24 (link)]. In an aluminum test tube, 3.00 g of lily starch and 25.0 mL of deionized water were combined. The slurry was elevated to 95 °C for 2.5 min and held at that temperature for 5 min before being cooled to 50 °C in 4 min and equilibrated for 2 min. Starch pasting profiles were obtained, and peak viscosity (PV), breakdown (BD, which is PV minus TV), final viscosity (FV), setback (SB, which is FV minus TV), peak time (Pt), and pasting temperature (PT) were obtained from the pasting curves by using the “Thermocline software” provided with the instrument.
+ Open protocol
+ Expand
4

Rapid Visco Analyser Flour Pasting

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pasting properties were determined using straight-grade flour with a Rapid Visco Analyser (RVA-4, Newport Scientific, Australia; Collar, 2003 (link)). A portion of 3.5 g flour and 25 g water were mixed in an aluminum cylindrical bowl. The following temperature variation program was applied: heating from 25 to 95°C for 6 min, holding for 3 min at 95°C and then decreased to 25°C for 7 min.
+ Open protocol
+ Expand
5

Rapid Viscosity Analysis of Starch Fractions

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pasting properties of the starch fractions were measured using a Rapid Visco Analyser (RVA-4; Newport Scientific, Warriewood, Australia) according to AACC Method 76-21 (1995) . Distilled water (25 mL) was added to 3.0 or 3.5 g of sample placed in the aluminum RVA canister. The suspensions were stirred thoroughly at 160 rpm. The temperature was first maintained at 50 °C for 1 min and then raised to 95 °C at a rate of 12 °C/min, held at 95 °C for 2.5 min, cooled to 50 °C at the same rate, and finally held at 50 °C for 2 min. Pasting parameters evaluated included: pasting temperature (P temp ), peak viscosity (PV), peak time (P time ), hot paste viscosity (HPV), final or cool paste viscosity (CPV), breakdown (PV-HPV), and setback (CPV-HPV). The experiments were conducted in triplicate.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists