The largest database of trusted experimental protocols

Bf xp 260 f

Manufactured by Olympus
Sourced in Japan

The BF-XP 260 F is a binocular microscope designed for laboratory use. It features advanced optics and a stable, durable construction for precise observation and analysis of samples. The core function of this product is to provide clear, high-resolution imaging of specimens for scientific and research applications.

Automatically generated - may contain errors

2 protocols using bf xp 260 f

1

Flexible Bronchoscopy in Neonatal Intensive Care

Check if the same lab product or an alternative is used in the 5 most similar protocols
Flexible bronchoscopy was performed using Olympus (BF-XP 60, BF-XP 260 F, or BF-XP 290) bronchoscopes. To prevent vomiting and aspiration, patients did not consume for 2 h before FB. FB was performed at the bedside in the NICU. Midazolam, injected intravenously at a dose of 0.1 mg/kg, was used for sedation. Local anesthesia with 1% lidocaine was administered. All FBs were performed by two senior pediatric pulmonologists. Depending on the patient’s clinical condition, the bronchoscopy was performed transnasally via a laryngeal mask or an endotracheal tube. Stable ventilated newborns were extubated in the process of the procedure so as to evaluate any upper airway anatomic and dynamic disease. Pulse rate, electrocardiogram, and arterial oxygen saturation (SaO2) were recorded continuously during the procedure, and non-invasive blood pressure was monitored every 3–5 min. Supplemental oxygen was given by nasal tube on demand. If the SaO2 fell below 90%, FB was suspended and attempted again after SaO2 recovery.
+ Open protocol
+ Expand
2

Transbronchial P25 TiO2 Instillation in Rabbits

Check if the same lab product or an alternative is used in the 5 most similar protocols
Rabbits were anesthetized by intramuscular injection of ketamine 5 mg/kg (Huons Co.,
Korea) and xylazine 0.8 mg/kg (Bayer, Republic of Korea). Oxygen saturation was monitored
by pulse oxymeter in the ear. Transbronchial P25 TiO2 instillation was
performed using an ultrathin bronchoscope (BF-XP260F, Olympus; Tokyo, Japan). The
ultrathin bronchoscope was inserted into the target bronchus as deep as possible under
direct vision. The instillation catheter was inserted beyond the visible bronchus through
working channel. One ml of 10 µg P25 TiO2 was once instilled
into the right lung through the catheter and 1 ml of normal saline (as control) was
instilled into the left lung (N=3). One ml of 50 and 250 µg P25
TiO2 were instilled in the same way (N=3 in each group).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!