Ms qqq mass spectrometer

Manufactured by Agilent Technologies
Sourced in Germany, United States

The MS QQQ mass spectrometer is an analytical instrument designed for sensitive and selective detection of target analytes in complex samples. It operates on the principle of triple quadrupole mass spectrometry, providing high-performance quantitative and qualitative analysis capabilities.

Automatically generated - may contain errors

2 protocols using ms qqq mass spectrometer

1

UPLC-MS/MS for Metabolite Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analysis was performed on a MS QQQ mass spectrometer coupled to Aglient 6420 series UPLC system (Agilent Technologies, Waldbronn, Germany), equipped with a 1290 ultra-performance auto sampler, 1290 infinity Quad pump, and 6420 triple quadrupole detector. Chromatographic separation was performed on a Acquity UPLC® HSS T3 (150 mm × 2.1 mm i.d.; 1.8 μm) column (Waters, USA).
+ Open protocol
+ Expand
2

Cycloalliin Quantification by LC/MS QQQ

Check if the same lab product or an alternative is used in the 5 most similar protocols
To analyze the cycloalliin, sample (or cycloalliin hydrochloride monohydrate as a standard, Fujifilm Wako Pure Chemical Co., Osaka, Japan) was dissolved in methanol at 0.1 g/mL. Agilent 6410 Triple Quad LC/MS (Agilent Technologies, Santa Clara, CA, USA) coupled to a MS QQQ mass spectrometer equipped with an electrospray ionization sources (Agilent Technologies) was used. Chromatographic separations were performed on a reversed phase C18 with polar end-capping (15 mm × 2 mm, SynergiTM 4 μm Hydro-RP 80Å; phenomenex, Torrance, CA, USA). The operating temperature was set at 30 °C and the flow rate was 0.2 mL/min. Mobile phase A and B consisted of 0.1% formic acid in water and 0.1% formic acid in acetonitrile, respectively. The gradient system was as follows: 0 min, 5% B; 1 min, 5% B; 11 min, 100% B; 12 min, 100% B; 15 min, 5% B; and 20 min, 5% B. The mass spectrometer was operated using MS QQQ mass spectrometer for electrospray ionization (ESI). The general settings used were as follows: gas temperature, 300 °C; gas flow, 11 L/min; nebulizer, 15 psi; capillary, 4000 V. Regression equation (y) is 233.26x + 259.29 and correlation coefficient (R2) is 1.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!