Phi 5702 multi functional x ray photoelectron spectrometer

Manufactured by Physical Electronics
Sourced in United States

The PHI-5702 is a multi-functional X-ray photoelectron spectrometer (XPS) designed for surface analysis. It utilizes X-ray excitation to eject photoelectrons from the surface of a sample, allowing for the determination of the elemental composition and chemical state of the material.

Automatically generated - may contain errors

3 protocols using phi 5702 multi functional x ray photoelectron spectrometer

1

Comprehensive Structural and Compositional Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The crystal structures, morphologies and microstructures of the samples were characterized by X-ray powder diffraction (XRD) and scanning/transmission electron microscopy (SEM/TEM). The used apparatuses were a D8 Advance X-ray diffractometer (Bruker AXS, Karlsruhe, Germany), a JSM-6701F field-emission scanning electron microscope (JEOL Ltd., Tokyo, Japan) and a JEM-1200EX field-emission transmission electron microscope (JEOL Ltd., Tokyo, Japan). A PHI-5702 multi-functional X-ray photoelectron spectrometer (Physical Electronics, hanhassen, MN, USA) was employed for the X-ray photoelectron spectroscopy (XPS) analysis. Ultraviolet-visible (UV-vis) diffuse reflectance spectroscopy (DRS) measurements were performed on a TU-1901 double beam UV-vis spectrophotometer (Beijing Purkinje General Instrument Co. Ltd., Beijing, China). A Spectrum Two Fourier transform infrared (FTIR) spectrophotometer (PerkinElmer, Waltham, MA, USA) was used for the FTIR spectroscopy analysis of the samples.
+ Open protocol
+ Expand
2

Comprehensive Material Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
A D8 Advance X-ray diffractometer (Bruker AXS, Karlsruhe, Germany) with λCu-kα = 0.15406 nm was used to record the X-ray powder diffraction (XRD) patterns of the samples. Scanning/transmission electron microscopy (SEM/TEM) investigations were performed on a JSM-6701F field-emission scanning electron microscope (JEOL Ltd., Tokyo, Japan) and a JEM-1200EX field-emission transmission electron microscope (JEOL Ltd., Tokyo, Japan). A PHI-5702 multi-functional X-ray photoelectron spectrometer (Physical Electronics, hanhassen, MN, USA) was used for the X-ray photoelectron spectroscopy (XPS) analyses. Fourier transform infrared (FTIR) spectroscopy was analyzed on a Spectrum Two FTIR spectrophotometer (PerkinElmer, Waltham, MA, USA).
The photoelectrochemical properties of the samples, i.e., electrochemical impedance spectroscopy (EIS) and photocurrent response, were measured on a CST 350 electrochemical workstation according to the procedure elaborated in our previous work [47 (link)]. A Na2SO4 aqueous solution (0.1 mol L−1) served as the electrolyte. Simulated sunlight emitted from a 200-W xenon lamp (300 < λ < 2500 nm) was used as the light source. The preparation process of the working electrode was described in our previous work [49 (link)].
+ Open protocol
+ Expand
3

Comprehensive Materials Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
X-ray powder diffraction (XRD) was employed to investigate the phase purity of the samples on a D8 Advance X-ray diffractometer (Bruker AXS, Karlsruhe, Germany). The morphologies and microstructures of the products were observed by field-emission scanning electron microscopy (SEM) and field-emission transmission electron microscopy (TEM). The SEM investigation was performed on a JSM-6701F scanning electron microscope (JEOL Ltd., Tokyo, Japan), and the TEM observation was carried out on a JEM-1200EX transmission electron microscope (JEOL Ltd., Tokyo, Japan). X-ray photoelectron spectroscopy (XPS) was used to record the chemical states of the elements on a PHI-5702 multi-functional X-ray photoelectron spectrometer (Physical Electronics, Chanhassen, MN, USA). The ultraviolet–visible (UV-Vis) diffuse reflectance spectra of the samples were tested by using a TU-1901 double beam UV-Vis spectrophotometer (Beijing Purkinje General Instrument Co. Ltd., Beijing, China) with BaSO4 as a reference. An RF-6000 fluorescence spectrophotometer (Shimadzu, Kyoto, Japan) was available to record the PL spectra of the samples (excitation wavelength: ~350 nm).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!