The largest database of trusted experimental protocols

1 2 bis dimethylamino ethane temed

Manufactured by Sangon
Sourced in China

1,2-bis(dimethylamino)-ethane (TEMED) is a chemical compound commonly used as a catalyst in polyacrylamide gel electrophoresis (PAGE) applications. It functions to accelerate the polymerization of acrylamide and bisacrylamide, which are the main components of polyacrylamide gels. TEMED facilitates the formation of free radicals, leading to the rapid crosslinking of the gel matrix.

Automatically generated - may contain errors

2 protocols using 1 2 bis dimethylamino ethane temed

1

Enzymatic Biotin-Labeling Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
NEB buffer 4 and Nt.BbvCI endonuclease were obtained from New England BioLabs (Ipswich, MA, USA), and the polymerase Klenow fragment exo- was purchased from Thermo Fisher Scientific Inc. (Waltham, MA, USA). Streptavidin-coated 96-well plates were purchased from BEAVER Nano-Technologies (Suzhou, China). 3-[(3-Cholamidopropyl)dimethylammonio]-1-propanesulfonic acid (CHAPS), tris(2-carboxyethyl)phosphine hydrochloride (TCEP), Tween 20, and invertase from baker’s yeast were purchased from Sigma-Aldrich (St. Louis, MO, USA). Ethylene glycol, bis(aminoethyl ether)-N, N, N’, N’ tetraacetic acid (EGTA), glycerol, sulfosuccinimidyl-4-(N-maleimidomethyl)-cyclohexane-1-carboxylate (sulfo-SMCC), bovine serum albumin (BSA), deoxynucleotide triphosphate (dNTP) solution mixture, 40% acrylamide mix solution, ammonium persulfate (APS), and 1,2-bis(dimethylamino)-ethane (TEMED) were obtained from Sangon Biotechnology Co. Ltd. (Shanghai, China). All other chemicals were of analytical grade and were used as received without purification. All water used in this work was RNase-free.
The oligonucleotides used in this assay (Table 1) were synthesized and purified by Sangon Biotechnology Co. Ltd. (Shanghai, China). Buffer I (0.1 M NaCl, 0.1 M sodium phosphate buffer, pH 7.3, 0.05% Tween-20) was used throughout the experiment.
+ Open protocol
+ Expand
2

Telomerase Activity Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the oligonucleotides used in this study (Table S1) were synthesized and purified by Sangon Biotechnology Co. Ltd. (Shanghai, China), the modified sequences were HPLC purified, and other sequences without modification were ultraPAGE purified. A telomerase ELISA kit was obtained from Innovation Beyond Limits (Germany). Glycerol, deoxynucleotide triphosphates (dNTPs) solution mixture, 40% acrylamide mix solution, ammonium persulfate (APS), and 1,2-bis(dimethylamino)-ethane (TEMED) were obtained from Sangon Biotechnology Co. Ltd. (Shanghai, China). 4′,6-Diamidino-2-phenylindole (DAPI) was purchased from KeyGen Biotech. Co. Ltd. (Nanjing, China). 3-[(3-Cholamidopropyl)dimethylammonio]-1-propanesulfonic acid (CHAPS), Tween 20 and epigallocatechingallate (EGCG) were bought from Sigma-Aldrich (St. Louis, MO, USA). The transfection reagent, X-tremeGENE, was bought from Roche. All of the chemicals were of analytical grade and were used as received without any purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!