The largest database of trusted experimental protocols

Rp 8 f254

Manufactured by Merck Group

The RP-8 F254 is a type of laboratory equipment used for thin-layer chromatography (TLC) analysis. It is a silica gel-based stationary phase with a C8 (octyl) functional group and a fluorescent indicator (F254) for visualization under UV light. The core function of the RP-8 F254 is to enable the separation and identification of chemical compounds through TLC techniques.

Automatically generated - may contain errors

3 protocols using rp 8 f254

1

Isolation and Characterization of Natural Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemicals and reagents were from Merck (Darmstadt, Germany). Evaporation of solvents was performed on a vacuum rotary evaporator (Rotavapor R-3000r, Buchi, Switzerland). FCPC was carried out on a Kromaton instrument equipped with a 1000-ml column, adjustable rotation of 200–2000 rpm and a preparative Laboratory Alliance pump with a pressure safety limit of 50 bar. NMR spectra in MeOD were recorded at 400 and 600 MHz (Bruker Advance III 600 MHz and DRX 400). 2D NMR experiments, including correlation spectroscopy (COSY), heteronuclear single-quantum correlation (HSQC) and heteronuclear multiple-bond correlation (HMBC) were performed using standard Bruker microprograms. Electrospray ionisation mass spectrometry (ESI-MS) experiments were performed on a LTQ-Orbitrap XL hybrid mass spectrometer (Thermo-Scientific, Bremen, Germany). Analytical TLC was performed on Merck Kieselgel 60 F254 or RP-8 F254 plates. Spots were visualized by UV light (254 and 365 nm) or by spraying with sulfuric vanillin. The plates were then heated for 2 min at 110°C. Preparative TLC was conducted on PLC Silica gel 60 F254 plates (1 mm). The selected zones were scraped and extracted with ethyl acetate to separate the corresponding compounds. Column chromatography was performed on silica gel 70–230 mesh (63–200 μm). Size exclusion chromatography was performed on Sephadex LH-20.
+ Open protocol
+ Expand
2

Isolation of Phytochemicals via FCPC

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemicals and reagents were from Merck (Darmstadt, Germany). Evaporation of solvents was performed on a vacuum rotary evaporator (Rotavapor R-3000r, Buchi, Switzerland). Fast Centrifugal Partition Chromatography (FCPC) was carried out on a Kromaton FCPC instrument equipped with a 1,000-mL column, adjustable rotation of 200–2,000 rpm and a preparative Laboratory Alliance pump with a pressure safety limit of 50 bar. NMR spectra in CDCl3 were recorded at 400 and 600 MHz (Bruker Advance III 600 MHz and DRX 400). 2D NMR experiments, including COSY, HSQC, and HMBC were performed using standard Bruker microprograms. Analytical TLC was performed on Merck Kieselgel 60 F254 or RP-8 F254 plates. Spots were visualized by UV light (254 and 365 nm) or by spraying with sulfuric vanillin. Preparative TLC was conducted on TLC Silica gel 60 F254 plates (1 mm). The selected zones were scraped and extracted with ethyl acetate to separate the corresponding compounds. Column chromatography was performed on silica gel 70–230 mesh (63–200 μm). Size exclusion chromatography was performed on Sephadex LH-20.
+ Open protocol
+ Expand
3

Analytical and Preparative Thin-Layer Chromatography

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical TLC was performed on Merck Kieselgel 60 F254 or RP-8 F254 plates of 0.2 mm layer thickness. The plate was visualized by UV light or by spraying with H2SO4/AcOH/H2O (1:20:4), followed by heating at 120 °C for about 1 min. The plates were then heated for 5 min at 120 °C. Preparative TLC was performed on Merck Kieselgel 60 F254 plates, of 0.5 or 1 mm film thickness. Column chromatography (CC) was performed on Fluka (Seelze, Germany) Amberlite XAD-4, on Merck Kieselgel 60 (70–240 µm) and Merck Kieselgel 60 (40–63 µm), or on Baker (Deventer, The Netherlands) RP-18.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.