The largest database of trusted experimental protocols

Clone r10z8e9

Manufactured by Bio-Rad

The Clone R10Z8E9 is a laboratory equipment product manufactured by Bio-Rad. It is designed for a specific core function, but a detailed description while maintaining an unbiased and factual approach is not available.

Automatically generated - may contain errors

2 protocols using clone r10z8e9

1

ELISA Quantification of Human IgG

Check if the same lab product or an alternative is used in the 5 most similar protocols
ELISA plates were coated overnight at 4°C with 0.1 μg/mL of mouse anti-human IgG (human CH2 domain with no cross-reactivity to rhesus macaque IgG; clone R10Z8E9; BioRad) and then blocked for 2 h. The serum samples were assayed at 4-fold dilutions starting at a 1:100 dilution in ELISA diluent (PBS containing 1% heat-inactivated FBS and 0.2% Tween-20). Samples were incubated for 1 h at ambient temperature and then removed, and plates were washed. Wells then were incubated for 1 h with goat anti-human IgG conjugated to HRP (ThermoFisher Scientific) at a 1:20,000 dilution. Wells were washed and then incubated with TMB substrate (KPL) (100cμL/well) and incubated for 10cmin followed by 1N hydrochloric acid stop the reaction (100cμL/well). Microplates are read at 450cnm with 650cnm subtraction with an OD450cnm cut-off of 0.052 (Biotek Cytation reader). Human mAbs were quantified using Prism software, version 7.04 (GraphPad), to analyze sigmoidal dose-response (variable slope), using 1:1 mixture of rEBOV-520 LALA and rEBOV-548 IgG1 cocktail as a standard.
+ Open protocol
+ Expand
2

ELISA for Quantifying Human IgG Antibodies

Check if the same lab product or an alternative is used in the 5 most similar protocols
ELISA plates were coated overnight at 4°C with 0.1 μg/mL of mouse anti-human IgG (human CH2 domain with no cross-reactivity to rhesus macaque IgG; clone R10Z8E9; BioRad) and then blocked for 2 hrs. The serum samples were assayed at 4-fold dilutions starting at a 1:100 dilution in ELISA diluent (PBS containing 1% heat-inactivated FBS and 0.2% Tween-20). Samples were incubated for 1 hr at ambient temperature and then removed, and plates were washed. Wells then were incubated for 1 hr with goat anti-human IgG conjugated to HRP (ThermoFisher Scientific) at a 1:20,000 dilution. Wells were washed and then incubated with TMB substrate (KPL) (100 μL/well) and incubated for 10 min followed by 1N hydrochloric acid stop the reaction (100 μL/well). Microplates are read at 450 nm with 650 nm subtraction with an OD450 nm cut-off of 0.052 (Biotek Cytation reader). Human mAbs were quantified using Prism software, version 7.04 (GraphPad), to analyze sigmoidal dose-response (variable slope), using 1:1 mixture of rEBOV-520 LALA and rEBOV-548 IgG1 cocktail as a standard.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!