Chemical silica gel 60n

Manufactured by Kanto Chemical
Sourced in Japan

Chemical silica gel 60N is a type of chromatography packing material used in laboratory applications. It is a porous, high-purity silica gel that serves as a stationary phase for column chromatography techniques. The 60N designation refers to the specific particle size and pore characteristics of the silica gel.

Automatically generated - may contain errors

3 protocols using chemical silica gel 60n

1

Comprehensive Analytical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical TLC was performed on Kieselgel F254 plates (Merck, Darmstadt, Germany) and visualized by UV light (254 nm, Axel, Osaka, Japan). Column chromatography was performed using Chemical silica gel 60N (neutral, KANTO Chemical, Tokyo, Japan). Physical data were obtained as follows. NMR spectra were recorded on a Bruker FT-NMR AV400 or AV500 instrument (Billerica, MA, USA). 1H NMR spectra were recorded at 400 or 500 MHz, referenced to TMS in CDCl3 (0.00 ppm), DMSO-d6 (2.50 ppm). 13C NMR spectra were recorded at 100 or 125 MHz, referenced to TMS in CDCl3 (0.00 ppm). 31P NMR spectrum was recorded at 162 or 202 MHz, referenced to phosphoric acid as an external reference in CDCl3 (0.00 ppm). Chemical shifts are reported in parts per million (δ), and signals are expressed as s (singlet), d (doublet), t (triplet), q (quartet), m (multiplet), or br (broad). All exchangeable protons were detected by addition of D2O. Mass spectra were recorded on a quadrupole SQD2 spectrometer (Waters, Milford, MA, USA) for LRMS or a TOF SYNAPT G2-Si HDMS spectrometer (Waters) for HRMS. All the chemical reagents and solvents used were commercially available and used without further purification.
+ Open protocol
+ Expand
2

Optimization and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the reagents were obtained from commercial sources and used without further purification. The solvents were not anhydrous-grade. Flash chromatography was performed using Kanto Chemical silica gel 60N (spherical, neutral). JEOL JNM-ECX400P (JEOL, Japan) was used to record 1H NMR and 13C NMR spectra. Chemical shifts for 1H NMR spectra were reported as δ in parts per million (ppm) downfield from SiMe4 (δ 0.0) and relative to the signal of CDCl3 (δ 7.26, singlet), while 13C NMR spectra were reported as δ in ppm downfield from SiMe4 (δ 0.0) and relative to the signal of CDCl3 (δ 77.16, triplet). HPLC and MS spectra were recorded on a Shimadzu LC20A system (Shimadzu Corporation, Japan) and LCMS-2010EV or a Shimadzu LC20A XR system and amaZon SL, using a C18 column (YMC-Pack Pro C18, 5 µm, 250 mm × 4.6 mm ID; MonoBis low-pressure type, 11 nm, 150 mm × 3.2 mm ID; Kinetex 5 µm EVO C18 100 Å LC Column, 250 mm × 4.6 mm ID; or Kinetex 1.7 µm EVO C18 100 Å LC Column, 100 mm × 2.1 mm ID) with detection at 215 nm. Chemiluminescent nitrogen detector (CLND) spectra were recorded on a Shimadzu LC10A system and Antek 8060 (PAC, Houston, TX, USA). High-resolution mass spectra (HRMS) were recorded on Bruker ultrafleXtreme (Bruker, Billerica, MA, USA). (Copies of the 1H-NMR and HPLC charts and experimental data for compounds.are shown in Supplementary Materials)
+ Open protocol
+ Expand
3

Characterization of Chemical Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
General Methods Physical data were measured as follows: 1 H, 13 (link) C, and 31 P-NMR spectra were recorded at 400 or 500 MHz, 100 or 125 MHz, and 162 or 202 MHz instruments (Bruker FT-NMR AV400 or AV500), respectively in CDCl 3 or dimethyl sulfoxide (DMSO)-d 6 as the solvent with tetramethylsilane or H 3 PO 4 as an internal or external standard. Chemical shifts are reported in parts per million (ppm), and signals are expressed as s (singlet), d (doublet), t (triplet), m (multiplet), or br (broad). All exchangeable protons were detected by addition of D 2 O. Mass spectra were measured on a SQD2 (Waters, U.S.A.) and BioAccord (Waters). TLC was done on Merck Kieselgel F254 precoated plates. Silica gels used for column chromatography were KANTO Chemical silica gel 60 and KANTO Chemical silica gel 60N (neutral).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.