The largest database of trusted experimental protocols

Biograph hi rez

Manufactured by Siemens

The Biograph Hi-rez is a high-resolution medical imaging device designed for diagnostic and research applications. It is capable of producing detailed images of the body's internal structures and functions. The core function of the Biograph Hi-rez is to capture and process medical images using advanced imaging technology.

Automatically generated - may contain errors

3 protocols using biograph hi rez

1

FDG-PET Imaging in Neurodegenerative Disorders

Check if the same lab product or an alternative is used in the 5 most similar protocols
All patients underwent [18F]FDG-PET scans performed with PET cameras manufactured by GE Healthcare medical systems (GE Healthcare, Chicago, IL): GE Discovery PET/CT 690 (PD cohort: PD-LDR and PD-HDR, 256×256 matrix with a voxel size of 1.95 mm) and STE scanner (DLB, MSA and iRBD, 128×128 matrix with a pixel size of 1.95 mm). The [18F]FDG PET scans of 112 HC subjects were obtained using either a GE Discovery ST, GE Discovery STE, Siemens Biograph Hi-rez or Siemens ECAT EXACT HR + PET scanner (see (Caminiti et al., 2021 (link), Presotto et al., 2017 (link))). The [18F]FDG-PET acquisition procedures fulfilled the European Association of Nuclear Medicine guidelines (Varrone et al., 2009 (link)). Before radiopharmaceutical injection, subjects fasted for at least 6 h to ensure that the measured blood glucose level was <120 mg/dL. Subjects underwent a 3D PET scan (time interval between injection and scan start ranged from 30 to 45 min; scan duration ranged from 10 to 15 min) after the injection of [18F]FDG (185–250 MBq: usually, 5–8 mCi via a venous cannula). Reconstruction of all images was performed using an ordered subset-expectation maximisation algorithm (OSEM, 28 subsets, 2 iterations, 2-mm post-filter). For all clinical groups, CT scans were used for attenuation correction.
+ Open protocol
+ Expand
2

Robustness Study of PET/CT Scanners

Check if the same lab product or an alternative is used in the 5 most similar protocols
Eleven PET/CT scanners were used for the robustness study: n. 2 Discovery ST (S1, S2) [17 (link)], n. 1 Discovery STE (S3) [18 (link)], n. 2 Discovery 600 (S4, S5) [19 (link)], and n. 1 Discovery 690 (S6) [20 (link)] (GE Healthcare, Milwaukee, WI), n. 1 Biograph HI-REZ (S7) [21 (link)] and n. 1 Biograph TRUEV (S8) [22 (link)] (SIEMENS Medical Solutions, Knoxville, TN), n. 1 Gemini XL (S9) and n. 2 Gemini TF (S10, S11) [23 (link)] (Philips Medical Systems, Cleveland, OH). The technical characteristics and physical performances of the PET/CT scanners were derived from factory data and/or previous publications and are reported in Table 1.
+ Open protocol
+ Expand
3

FDG-PET Imaging for Interictal Seizure Detection

Check if the same lab product or an alternative is used in the 5 most similar protocols
FDG-PET was performed using 2-[ 18 F]fluoro-2-deoxy-d-glucose in all patients in the interictal phase (at least 24 hours after the last seizure). Patients, having fasted at least 6 hours, received an injection of 200 MBq or a weightadapted dose in children, according to the EANM pediatric card (http://www.eanm.org/content-eanm/uploads/2017/01/EANM_Dosage_Card_040214.pdf) of [ 18 F]FDG, while resting in a quiet and dimly lit room. In all patients, the EEG was continuously monitored during the thirty minutes uptake time to exclude subclinical seizures, leading potentially to false negative or positive findings. PET images were acquired on tomographs equipped with lutetium oxyorthosilicate (LSO) crystals, namely the Siemens Biograph Hi-Rez, TruePoint or mCT PET/CT systems, in 3D mode. Scan duration was twenty minutes.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!