The largest database of trusted experimental protocols

Metavue 4 6r8

Manufactured by Universal Imaging
Sourced in Japan

The Metavue 4.6r8 software is a digital imaging application that provides image acquisition, processing, and analysis functionalities. It is designed to work with various types of microscopes and imaging devices. The software allows users to capture, view, and manipulate digital images for scientific and research purposes.

Automatically generated - may contain errors

2 protocols using metavue 4 6r8

1

Microscopic Analysis of Bacterial Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were grown in SM with or without 2% glucose, 100 μl of the culture was centrifuged, and 80 μl of the supernatant was removed. The cells were then resuspended in the remaining 20 μl. Portions (2 μl) of each sample were mounted on glass slides treated with 0.1% (wt/vol) poly-l-lysine (Sigma). If necessary, 4′,6-diamidino-2-phenylindole (DAPI) solution (1 mg/ml in water) was added to the cell suspension at 1 μg/ml. Microscopy was performed with an Olympus BX51 phase-contrast and fluorescence microscope with a 100× Plan-N objective (Olympus, Tokyo, Japan). Images were captured using a CoolSNAP HQ charge-coupled device camera (Nippon Roper, Tokyo, Japan) and Metavue 4.6r8 software (Universal Imaging, PA).
+ Open protocol
+ Expand
2

Microscopic Analysis of Bacterial Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were picked up from flesh colony on LB agar plate and inoculated to 1 ml of LB medium in L-tube. The tube was shaken for 14 h at 37°C. One hundred microliters of the culture was centrifuged, and 80 μl of the supernatant was removed. The cells were then resuspended in the remaining 20 μl. Portions (2 μl) of each sample were mounted on glass slides treated with 0.1% (wt/vol) poly-L-lysine (Sigma-Aldrich, MO, United States). Microscopy was performed with an Olympus BX51 phase contrast and fluorescence microscope with a 100 × PLAN-N objective (Olympus, Tokyo, Japan). Images were captured using a CoolSNAP HQ charge-coupled device camera (Nippon Roper, Tokyo, Japan) and Metavue 4.6r8 software (Universal Imaging, PA, United States).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!