The largest database of trusted experimental protocols

6 protocols using chloroform

1

Synthesis and Characterization of PTMSP

Check if the same lab product or an alternative is used in the 5 most similar protocols
PTMSP (SSP-070, lot 9D-35578, MW 250 × 103 g/mol [43 (link)]) was purchased from Gelest, Inc. (Morrisville, PA, USA). Macronet ™ MN200 commercial sorbent (batch: 113X/18/15) was purchased from Purolite Ltd. Chloroform (chemical grade, CHIMMED, Moscow, Russia) was taken without further purification.
+ Open protocol
+ Expand
2

Synthesis and Characterization of PLGA-based Biomaterials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Poly(DL-lactide-co-glycolide) 50:50 (PLGA, Mw 45 kDa) was obtained from Boehringer Ingelheim (Belgium); oligo-(l)-lactide (OLL, Mw 5 kDa), oligo-(D)-lactide (OLD, Mw 5 kDa) were synthesized from the respective lactic acid isomers as described earlier [14 (link)]; Dextran sulphate sodium salt (DS) (Mw~9–15 kDa), Poly-l-arginine hydrochloride (PAr, Mw~15–70 kDa), Polyallylamine hydrochloride (PAH, Mw~58 kDa), Poly(sodium 4-styrenesulfonate) (PSS) (Mw~70 kDa), Poly vinyl alcohol (PVA, Mw 70 kDa), Fluorescein isothiocyanate (FITC), Rhodamine B isothiocyanate (RBITC), Resazurin sodium salt, Crystal Violet, EDTA, zimozan were all obtained from Sigma-Aldrich (Saint Louis, MO, USA); Phosphate buffered Saline (PBS), DMEM/F12, trypsin, penicillin and streptomycin were purchased from PanEco (Moscow, Russia); Fetal calf serum (FCS) was obtained from Invitrogen (Carlsbad, CA, USA); Chloroform was obtained from Chimmed (Moscow, Russia); DMSO was obtained from Panreac (Castellar del Vallès, Spain).
+ Open protocol
+ Expand
3

Synthesis and Characterization of PTMSP

Check if the same lab product or an alternative is used in the 5 most similar protocols
PTMSP (SSP-070, lot 9D-35578) was purchased from Gelest, Inc. (USA). Macronet™ MN200 commercial sorbent (batch: 113X/18/15) was purchased from Purolite Ltd. Chloroform (chemical grade, Chimmed, Russia) was taken without further purification.
+ Open protocol
+ Expand
4

Microgel Synthesis and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
All materials for microgel synthesis were acquired from Sigma-Aldrich (Munich, Germany) unless stated otherwise. N-isopropylacrylamide (NIPAM—monomer,), N,N’- methylenebisacrylamide (BIS—crosslinking agent), ammonium persulfate (APS—initiator) were used as received. The organic solutions 1-octanol, 1-buthanol, decane, and tetradecane were purchased from Acros organics (Geel, Belgium). Tetrahydrofuran and acetone were received from PanReac AppliChem (Darmstadt, Germany). Chloroform, dioxane, 2-propanol, t-butanol, ethanol, hexane, dimethyl sulfoxide, acetonitrile, and cyclohexane were received from Chimmed (Moscow, Russia). Mineral oil was purchased from VWR (Darmstadt, Germany). The fat-soluble dye Sudan III (analytical standard) was obtained from Sigma-Aldrich (Munich, Germany). Water was purified using a Millipore Milli-Q system.
+ Open protocol
+ Expand
5

NADH-Dependent Biochemical Assays

Check if the same lab product or an alternative is used in the 5 most similar protocols
β-Nicotinamide adenine dinucleotide reduced was purchased from Serva (Heidelberg, Germany). Chloroform from Chimmed (Moscow, Russia), methanol from Merck (Darmstadt, Germany), D2O 99.9% from AstraChem (Saint-Petersburg, Russia) were used as received. H2O was deionized using an Ultra Clear UV plus TM water system (SG water, Hamburg, Germany) to the quality of 17.8 MOhm. Chemicals for HPLC were purchased from Sigma-Aldrich (St.Louis, MO, USA) and Cryochrom (Saint-Petersburg, Russia).
+ Open protocol
+ Expand
6

Polyethyleneimine-Based Polymer Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Polyethyleneimine (PEI) (Mw = 25,000, Mn = 10,000), poly(ethylene glycol) diglycidyl ether (PEGDGE) (Mn = 500), methanol (≥99.6%) (Sigma-Aldrich, St. Louis, MO, USA), chloroform, and 1-butanol (chemical grade, Chimmed, Russia) were taken without further purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!