The largest database of trusted experimental protocols

Spdm20a vp diode photodiode array detector

Manufactured by Shimadzu

The SPDM20A VP Diode Photodiode Array Detector is a laboratory equipment designed for spectrophotometric detection. It features a photodiode array that enables simultaneous detection of multiple wavelengths. The device is capable of high-speed data acquisition and can be used in various analytical applications.

Automatically generated - may contain errors

2 protocols using spdm20a vp diode photodiode array detector

1

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a Jasco-DIP-700 polarimeter at the sodium line (589 nm). UV spectra were obtained on a Hewlett-Packard 8453 spectrophotometer, and IR spectra were measured as a thin film on a CaF2 disc using a Perkin Elmer 1600 series FTIR. All 1D and 2D NMR spectra with the exception of 13C NMR spectra were acquired on a Varian Unity Inova 500 MHz spectrometer operating at 500 (1H) or 125 (13C) MHz using the residual solvent signals (δH 7.26 and δC.77.0) as an internal reference. 13C NMR spectra were acquired on a Varian Unity 600 MHz spectrometer. NMR samples were analyzed in 3 mm Shigemi NMR tubes. High-resolution mass spectrometry (HRMS) data were obtained on an Agilent 6545 LC-MS Q-ToF with ESI ionization in the positive mode. Gradient HPLC separations used a Shimadzu system consisting of LC-20AT Solvent Delivery Modules, an SPDM20A VP Diode Photodiode Array Detector, and an SCL-20A VP System Controller.
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a Jasco-DIP-700 polarimeter at the sodium line (589 nm). UV spectra were obtained on a Hewlett-Packard 8453 spectrophotometer and IR spectra were measured as a thin film on a CaF2 disc using a Perkin Elmer 1600 series FTIR. ECD measurements were obtained on a Chirascan Circular Dichroism Spectrometer with the samples dissolved in MeOH and placed in a 1 cm quartz cuvette with a solvent subtraction for baseline correction. NMR spectra were acquired on a Varian Inova Unity 500 MHz spectrometer operating at 500 (1H) or 125 (13C) MHz using the residual solvent signals as an internal reference. Samples were in 3 mm Shigemi tubes during NMR analyses. High-resolution mass spectrometry data were obtained on an Agilent LC-TOF or LC-QTOF with ES ionization. Gradient separations used a Shimadzu system consisting of LC-20AT Solvent Delivery Modules, an SPD-M20A VP Diode Photodiode Array Detector, and a SCL-20A VP System Controller. TLC analyses were performed on Si60F254 plates and visualized under UV or by heating after spraying with a 1% anisaldehyde solution in acetic acid:H2SO4 (50:1). Samples were weighted on a Mettler Toledo analytical balance.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!