The largest database of trusted experimental protocols

10 protocols using reference compounds

1

Cell Culture Supplies from Sigma-Aldrich

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference compounds, the medium, and other cell culture reagents were purchased from Sigma-Aldrich (Milan, Italy).
+ Open protocol
+ Expand
2

Quantification of Citrus Leaf Volatiles

Check if the same lab product or an alternative is used in the 5 most similar protocols
The citrus leaf VOCs and polar metabolites were separated by gas chromatography-mass spectrometry (GC-MS) using the same chromatographic conditions as reported in our previous study [9 (link)]. Peaks of interest were identified by comparing their mass spectra to those of authentic standards and by matching them to one of two mass spectral libraries with a score of at least 700 (Wiley Flavor and Fragrances of Synthetic and Natural Compounds or NIST 2011 Mass Spectral Database). Reference compounds were purchased from Sigma-Aldrich (St. Louis, MO, USA) at the highest available purity, and injected into the GC-MS under the same conditions as experimental samples to establish their retention time on the column. Peak areas were integrated using TurboMass software v. 5.4.2 (Perkin Elmer, Waltham, MA, USA), and were normalized to the area of the internal standard, trans-2-nonenal for VOCs and ribitol for polar metabolites. Quantification of compounds was based on the peak areas obtained from a dilution series of reference standards at known concentrations. Calibration curves were constructed from the linear regressions obtained by plotting the concentration vs. peak area for each reference compound at each concentration.
+ Open protocol
+ Expand
3

Reagents Purchased from Sigma-Aldrich

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference compounds, media, and other cell culture reagents were purchased from Sigma–Aldrich (Milan, Italy).
+ Open protocol
+ Expand
4

GC-MS Analysis of Volatile Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The profile of volatile compounds was mainly determined using headspace solid-phase micro-extraction (HS-SPME) [24 (link)] combined with gas chromatography-mass spectrometry (GC-MS) (Agilent 7890-B/5977A MS system, Agilent Technologies, Little Falls, DE, USA). The sample treatment and instrument operating parameters were carried out according to the methods described in our previous study [25 (link)]. The chromatographic peaks were qualitatively determined by matching the NIST 17s mass spectral library and Kovats index, which was calculated by the analysis of the C7–C40 n-alkane standard (Sigma-Aldrich, St. Louis, MO, USA) under the same chromatographic conditions as the samples. The concentration of each volatile compound was calculated quantitatively by the normalized method based on the peak area of the internal standard compound (2-octanol, 10 mg/L) and the correction factor of the reference compounds purchased from Sigma-Aldrich Chemical Co. (St. Louis, MO, USA).
+ Open protocol
+ Expand
5

FAAH Inhibition Assay Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference compounds, cell culture mediums and other reagents, along with plates and other physical supports for cell culture and enzyme assays were purchased from Merck Sigma (Milan, Italy) and Invitrogen (Basel, Switzerland). The FAAH enzyme, the substrate AMC-AA and the reference compound JZL-195 for the FAAH inhibition assay were obtained from Cayman Chemical (Ann Arbor, MI, USA).
+ Open protocol
+ Expand
6

Enzyme Inhibition Activity Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Enzymes, substrates, and reference compounds were from Sigma-Aldrich (St. Louis, MO, United States). The activity of enzymes was measured spectrophotometrically, as described in detail in (Makhaeva et al., 2017 (link)) using ATCh iodide, BTCh iodide, and 4-NPA as substrates for AChE, BChE, and CES, respectively. Experimental conditions: K,Na-phosphate buffer (100 mM), 25°С, pH 7.5 for AChE and BChE and pH 8.0 for CES assay. Measurements were carried out on a BioRad Benchmark Plus microplate spectrophotometer (Hercules, CA, United States).
Test compounds were dissolved in DMSO; final concentration of solvent in the incubation mixture was 2% (v/v). Initial assessment of inhibitory activity was carried out by determining the degree of enzyme inhibition at a compound concentration of 20 µM. For the most active compounds (inhibition ≥35%), IC50 values were determined.
Mechanism of BChE inhibition was assessed by a detailed analysis of enzyme kinetics with three increasing concentrations of inhibitor and six substrate concentrations as described in detail in Makhaeva et al. (2017) (link).
+ Open protocol
+ Expand
7

Cell Culture Supplies from Sigma-Aldrich

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference compounds, the medium, and other cell culture reagents were purchased from Sigma-Aldrich (Milan, Italy).
+ Open protocol
+ Expand
8

Preparation of LC-MS Compound Mix

Check if the same lab product or an alternative is used in the 5 most similar protocols
Acetonitrile and water (both LC-MS grade) were purchased from Fluka (Buchs, Switzerland). Reference compounds with a purity of > 99% were purchased from Sigma-Aldrich (Seelze, Germany). First, they were dissolved individually into stock solutions of 1 mM in either acetonitrile (nonpolar compounds) or in acetonitrile/water (50/50, v/v) (polar or very polar compounds). Afterwards, they were combined into a standard working mixture of 10 μM per compound.
+ Open protocol
+ Expand
9

Comprehensive Analytical Reagents for Metabolomic Studies

Check if the same lab product or an alternative is used in the 5 most similar protocols
Water (LC-MS grade), acetonitrile (LC-MS grade, ≥99.95 %), hexane (UV/IR grade, ≥99.5 %), methanol (LC-MS grade ≥ 99.95 %), isopropanol (LC-MS grade, ≥99.95 %), acetone (LC-MS grade, ≥99.9 %), butanol (for synthesis, ≥99.5 %), trichloromethane/chloroform (UV/IR grade, ≥99.8 %) and citric acid (≥99.5 % p.a.) were purchased from Carl Roth (Karlsruhe, Germany), ethyl acetate (Reag. Ph. Eur. ≥ 99.9 %) was purchased from Biosolve (Valkenswaard, Netherlands), formic acid (98 %) and acetic acid (100 %) from Fisher Scientific (Schwerte, Germany), hydrochloric acid (Reag. Ph. Eur., 37 %) and disodium hydrogen phosphate (NormaPur) from VWR Chemicals (Darmstadt, Germany), and 2,6-di-tert-butyl-4-methylphenol (BHT, 99 %) from Sigma-Aldrich (Munich, Germany). Reference compounds and isotopically labeled internal standards (IS) were purchased from Cayman Chemicals (Ann Arbor, MI, USA) for endocannabinoids and oxylipins, or Avanti Polar Lipids (Alabaster, AL, USA) for sphingolipids, LPAs, and lipids analyzed by LC-HRMS. For polar compounds, tryptophan and related metabolites, isotopically labeled IS and Reference compounds were purchased from Sigma-Aldrich or Cambridge Isotope Laboratories (Tewksbury, MA, USA). Detailed descriptions can be found in the supplementary material.
+ Open protocol
+ Expand
10

Analytical Reagents for LC-MS Metabolomics

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ultra LC-MS grade acetonitrile (ACN) and methanol (MeOH) were purchased from Carl Roth GmbH & Co KG (Germany). Ammonium acetate (AmAc) was purchased from Sigma-Aldrich (Taufkirchen, Germany). Pure water was obtained from a Milli-Q system (Millipore, USA) and used for the preparation of aqueous solvents. Reference compounds were purchased from Sigma Aldrich (Taufkirchen, Germany) unless otherwise indicated (Supplementary Table S1).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!